Watts R24-12-1111000 User Manual

Model Number PACK-
AGE
Gallons
Per
Minute
Pump (H.P.)
(Adj.)
Membrane
Size
Membrane
Array
Feed Water
Required*
(GPM)
Typical
Rejection
Dimensions Ship
Wt.
(Lbs.)
R24-08-1111000
110
7.5/TEFC 60%-75%
4" x 40" 2:1:1 17 98%
96"x24"x72"
800
R24-08-1131100
210
7.5/TEFC 60%-75%
4" x 40" 2:1:1 17 98%
96"x24"x72"
800
R24-10-1111000
1 12.5
7.5/TEFC 60%-75%
4" x 40" 2:2:1 21 98%
96"x24"x72"
900
R24-10-1131100
2 12.5
7.5/TEFC 60%-75%
4" x 40" 2:2:1 21 98%
96"x24"x72"
900
R24-12-1111000
115
7.5/TEFC 60%-75%
4" x 40" 3:2:1 25 98%
96"x24"x72"
1000
R24-12-1131100
215
7.5/TEFC 60%-75%
4" x 40" 3:2:1 25 98%
96"x24"x72"
1000
*At 65% recovery.
Feed water connection Product water connection 1" FNPT
1" FNPT
Reject water connection 3/4" FNPT Feed water pressure requirement (min.) 10 PSIG Drain requirement (maximum) 17, 21, 25 GPM Electrical requirement 230VAC/60hz Phase 3 Amps 20
Models
Specifications
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature
conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required. Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is 20” Full-Flow plastic housing and Flow-Pro
®
FPMB-BB5-20 melt blown filter cartridge. Systems are designed for use with municipal and well water
Powder coated steel frame
FRP multi-port pressure vessels
Pre-filter housing and cartridge (20” B-B)
Webtrol®multi-stage centrifugal pump
Automatic inlet valve
Low-pressure shut-off with auto restart
Tank level input
Pretreatment interlock input
Adjustable recycle line
Pre-filter pressure gauges
Pump discharge pressure gauge
Flow meter for product water
Flow meter for reject water
Flow meter for recycle water
Check valve for product water
Sample valves for product water
On / off switch
R-24 standard features (package #1 shown)
Additional features included with package #2
CI-1000 electronic controller with product water conductivity meter and alarm output
Programmable concentrate auto flush
WATER QUALITY & CONDITIONING PRODUCTS
®
®
WATER QUALITY & CONDITIONING PRODUCTS
Introduction
Watts Reverse Osmosis (R/O) Systems are designed to provide the commercial and industrial user with the most trouble free, cost effective and reliable form of water treatment available, by providing every option necessary for a successful installation.
Principles of Reverse Osmosis
Watts R/O systems employ thin film composite spiral wound membrane elements for superior performance. To simply describe the process, pump pressure is used to supply source water to reverse osmosis membranes. These special membranes allow only high quality water to permeate them. In turn, they reject metals, salts, ionic and organic impurities that are processed to waste. Suspended solids are removed by pre-filters, which are standard components on all Watts RO systems
.
Water temperature
Product water quality and production of any RO system is dependent on pressure and temperature. Watts™ RO systems are rated at standard conditions of 77˚F (25˚C), 60 psi (4.2 bar) inlet pressure and 1,000 TDS feed water quality. Higher temperatures will result in more water passing through the membranes and increased water production. As a rule, at given pressures and TDS levels, for each one-degree change in water temperature the change in water production is approximately 2%.
Water temperature Production Factor*
°F °C (Using thin film membranes) 40 4 0.48 50 10 0.60 60 16 0.73 70 21 0.88 77 25 1.00 80 27 1.06 90 32 1.26
*Percent of rated production.
Water pressure
Watts® commercial RO systems require a minimum of 10 psi feed pressure to function properly. The maximum pressure is 90 psi, and a pressure regulator must be utilized over 90 psi to reduce feed water pressure.
Feed / source water inlet requirements
The source water requirements shown below are essential for proper operation:
Note:
Pretreatment may be required if the above parameters are not met. Failure to meet feed water requirements may foul membranes, void the warranty and possibly make it necessary to down-rate performance.
All specifications listed are based on an average of 1,000 TDS feed water, 77°F (25°C) temperature and 60 psi (4.2 bar) pressure. Typically, higher-pressure differentials and higher temperatures increase water production and water quality. Maximum pressure and temperature limits must be observed.
Factor Requirement
Hardness <1 grain per gallon Free chlorine 0 ppm T.D.S. <1,000 ppm S.D.I. <5 pH 3-11 Iron <0.01 ppm Silica <25 ppm Manganese <0.05 ppm Turbidity <1 NTU Temperature 40°F - 95°F (4°C - 32°C) Pressure 10 - 90 psi (2.8 - 5.6 bar)
Inlet feed water requirements
Distributed by:
Feed
Water
Scale
Prevention
(Softener)
Chlorine Removal (Carbon)
Cartridge Pre-Filter
High
Pressure
Pump
R/O
Membranes
Waste
Product
Water
General RO Process Diagram
1. System location
The RO system should be located on a level surface in an area sheltered from sun, wind and rain. The temperature in this area should be maintained, and should not fall below 35°F, nor greater than 95°F. If these limits are exceeded, damage to components may result and the warranty may be considered void. It is important to allow sufficient space around the unit so maintenance can easily be performed.
2. Plumbing
The high-pressure pumps used require a continuous flow of water to the system. Minimum feed pressure is 10 psi. Please see table, below for minimum flow rates.
3. Feed water
Piping for feed water to the RO system should be either copper or plastic. Iron and carbon steel pipe will increase the iron content of the raw feed water and adversely affect the RO system's performance. Temperature of the feed water must not exceed 95°F.
4. Product water (permeate) line connection
Connect the product water (permeate) line to the manifold on the back side of the system. This line should not have valves and should run as directly as possible to the storage tank.
5. Concentrate (waste) line connection
Connect the waste line (concentrate) to the manifold on the back side of the system. The waste from the system should not have valves and should have an air break between it and the building drain system. The tubing or piping used for discharge of the concentrate should be run to an open drain in a free and unrestricted manner.
6. Electrical
The customer must provide a properly sized electrical service.
Level controls
In most installations it is necessary to use the level switch connector wire to install a level control or an electrical switch to turn the RO system on and off based on the water level in the storage tank.
Pumps
Never let pumps run dry. Operating pumps without sufficient feed water will cause damage. Feed pumps with filtered water only.
Pre-filtration
All Watts® RO systems come with particulate pre-filters to remove suspended particles down to five (5) micron in size. Change pre-filter cartridges at least every month or when there pressure differential of 10% or more that start-up pressure differential with clean cartridges.
Limited warranty
Watts® Commercial Reverse Osmosis systems are warranted to the original purchaser to be free of defects in material and workmanship for a period of one year from date of shipment. Should defects occur, Watts will repair or replace parts, which are defective. Shipping and labor costs are excluded for this limited warranty, and these costs are the customer's responsibility. Normal wear, accident, abuse, misuse, unauthorized alteration or repairs are also excluded. Watts will not be responsible for any incidental or consequential damages, losses or expenses arising from the installation or use of a Watts system. For warranty issues please call your dealer or Watts Water Quality & Conditioning Products at 800-659-8400.