Watts QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Installation, Operation And Maintenance Manual

IOM-HS-QTColdBevMax
Installation, Operation and Maintenance Manual
QTTM Cold Bev MaxTM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M,
QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M
Tested and certified by WQA against NSF/ANSI Standard 42 for the reduction of claims specified on the performance data sheet & NSF/ANSI 372 for "lead free" compliance.
!
WARNING
Read this Manual BEFORE using this equipment. Failure to read and follow all safety and use information
can result in death, serious personal injury, property damage, or damage to the equipment.
Keep this Manual for future reference.
!
WARNING
You are required to consult the local building and plumbing codes prior to installation. If the information in this manual is not consistent with local building or plumbing codes, the local codes should be followed. Inquire with governing authorities for additional local requirements.
QTCLDBMX-5S-.5M
Table of Contents
System Specications .................................2
Replacement Filters ...................................2
Notice to Installers ....................................2
Installation Precautions ................................2
Operation ..........................................2
Installation ..........................................3
Maintenance ........................................3
Filter Cartridge Replacement Procedure ...................3
Replacement Parts List ................................4
System Drawings ....................................4
Limited Warranty .....................................6
!
WARNING
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
System Specications
Maximum Pressure: All Systems - 100psi (6.8 bar) Minimum Pressure: All Systems - 20psi (1.4 bar) Maximum Temperature: 100°F (38°C)
Minimum Temperature: 40°F (4.4°C) Feed Water Quality: pH 6.5 to 8.5 Chlorine < 2ppm Iron (maximum) 0.3 mg/l Manganese (maximum) 0.05 mg/l Oil & H2S- None allowed For all other feed water quality requirements abide by the current
USEPA Safe Drinking Water Act standards. Inlet/Outlet Connections:
1S-.5M. All other systems have 1/2" (15mm) NPT connections Maximum Flow Rate:
System Model Flow Rate Chlorine Capacity
QTCLDBMX-1S-.5M 1.5 GPM (5.7 LPM) 10,000 Gallons
QTCLDBMX-2S-.5M 1.5 GPM (5.7 LPM) 10,000 Gallons
QTCLDBMX-3S-.5M 3 GPM (11.4 LPM) 20,000 Gallons
QTCLDBMX-4S-.5M 4.5 GPM (17.1 LPM) 30,000 Gallons
QTCLDBMX-5S-.5M 6 GPM (22.8 LPM) 40,000 Gallons
The QT Cold Bev Max line is available in different congurations depending upon ltration and ow requirements.
3
8" (10mm) NPT for model QTCLDBMX-
System Flow Rate and Capacity
Replacement Filters
System Replacement Filters
System Model Filter Ordering Code Frequency Description
QTCLDBMX-1S-.5M QTCB15S* 6 Months
HSR-L-SED-5M 6 Months 20" 5 Micron Sediment Pre Filter
QTCLDBMX-2S-.5M
QTCLDBMX-3S-.5M
QTCLDBMX-4S-.5M
QTCLDBMX-5S-.5M
QTCB15 6 Months
HSR-L-SED-5M 6 Months 20" 5 Micron Sediment Pre Filter
QTCB15 6 Months
HSR-L-SED-5M 6 Months 20" 5 Micron Sediment Pre Filter
QTCB15 6 Months
HSR-L-SED-5M 6 Months 20" 5 Micron Sediment Pre Filter
QTCB15 6 Months
15" QT 0.5 Micron Ultra Filtration Membrane And Carbon Block
15" QT 0.5 Micron Ultra Filtration Membrane And Carbon Block
15" QT 0.5 Micron Ultra Filtration Membrane And Carbon Block (2)
15" QT 0.5 Micron Ultra Filtration Membrane And Carbon Block (3)
15" QT 0.5 Micron Ultra Filtration Membrane And Carbon Block (4)
Notice to Installers
• Connect the system to cold water supply only. Water Temperature
cannot exceed 100°F (38°C).
• System must be installed in a vertical, upright and level position.
• Do not use with water that is microbiologically unsafe or of
unknown water quality.
• Notice to user/owner/operator: Please retain this manual for future
reference for parts, maintenance, or troubleshooting.
• It is recommended that all personnel responsible for operation and
maintenance of this product read the precautions, maintenance, and operation sections of this manual.
Installation Precautions
• Do not install system on line pressure above the rated pressure as
noted in System Specications above.
• Do not install the system on a hot water line. Failure to limit the
water temperature to 100°F (38°C) can result in housing failure and property damage.
• Do not connect the system backwards with the feed water line
connected to the outlet.
• Do not use liquid pipe thread compounds for threaded connections. Use Teon
• Do not solder plumbing connections that are attached to the housings or inlet/outlet ttings. System damage may occur due to high temperature.
• Do not allow the system to freeze. Turn off water supply and drain
the system if temperature falls below 32°F (0°C).
• Do not install system in direct sunlight or where the system will be
exposed to harsh chemicals or may be subjected to being hit by moving equipment, carts, mops, or any other item that may cause damage.
• Allow 3" (76mm) minimum clearance under the housings for lter
replacement.
• If water hammer is evident, install water hammer arrestors before
the system.
• Do not over tighten tting connections.
• Always back up valves and ttings with a wrench when installing
ttings to avoid over tightening or loosening existing ttings.
• Do not install the unit behind equipment where it may be difcult to
access the system for future lter replacements.
Position the system in a suitable location. The direction of ow through the system is left to right. Keep this in mind when determin­ing installation locations. Do not mount the system near any source of heat. Also do not mount this system over anything that may be adversely affected by water.
®
tape only.
Operation
With sufcient pressure, operation of this system is completely auto­matic. Dependable operation involves only monitoring system pres­sure differential, periodic lter changes, and service documentation.
NOTICE
Filter cartridges should be changed at end of filter life, due to lack of filtering performance, or whenever a 15 psi pressure drop or greater is experienced during normal operation, whichever comes first.
For all replacement filters and components contact your authorized Hydro-Safe Foodservice representative.
*Note: The QTCB15S is the same filter as the QTCB15. Only the label position has been changed so that the label faces forward on single cartridge systems.
NOTICE
Cartridge capacities are estimates and may be less depending on incoming water quality.
2