Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
!
WARNING
You are required to consult the local building and plumbing
codes prior to installation. If the information in this manual
is not consistent with local building or plumbing codes, the
local codes should be followed. Inquire with governing
authorities for additional local requirements. Use only
lead-free solder and flux for sweat-solder connections, as
required by state, province and federal codes.
IOM-WQ-PWSYS-WH-GAC
!
WARNING
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
PWSYS-WH-GAC
Table of Contents Pages
Important Safety Information – Read All .......................2
Instructions Before Using.................................. 2
If you are unsure about installing your Watts water filter, contact
a Watts representative or consult a professional plumber.
!
WARNING
Install the system in a protected area. For more informa-
tion on where to install the filter see the Installation Considerations section of this manual.
• Do not attempt to treat water over 110°F (43°C) with the
system. Always connect the system to the main water supply pipe before the water heater.
• Do not expose the system to freezing temperatures. Water
freezing in the system causes equipment damage.
• Do not install in direct sunlight. Ultraviolet rays from the
sun may cause damage.
• Minimum inlet water pressure is 30psi. Maximum inlet
water pressure is 125psi.
!
CAUTION
Test the water periodically to verify that the system is performing satisfactorily.
Discard small parts remaining after the installation.
Installation Considerations
Consider the following points when determining where to install
the filter:
• Do not install the lter where it would block access to the water
heater, or access to the main water shutoff, water meter, or electrical panels.
• Install the lter in a place where water damage is least likely to occur if a leak develops.
• Always connect the system to the main water supply pipe before
the water heater.
• Install the system where it will not be subject to temperatures
outside of the limits stated in the Specification section or to direct
sunlight.
• Make sure the installation surface is smooth, level, and sturdy
enough to support the weight of the wetted system.
NOTICE
Failure to install the system correctly voids the warranty.
Handle all components of the system with care. Do not drop,
drag or turn components upside down.
Be sure the floor under the water filter system is clean, level and
strong enough to support the unit.
Filter Anatomy
1
3
4
6
2
ITEM #DESCRIPTION
1Bypass
2Tank Head
3Tank
4Distributor
5Gravel Underbed
6Filter Media
5
2
Specifications
Feed Water Parameters
!
WARNING
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the
system.
Minimum inlet pressure: 30 psig
Maximum operating pressure: 125 psig
Minimum water temperature: 34°F (1°C)
Maximum water temperature: 110°F (43°C)
Installation
Location: Indoors (Protect from direct sunlight)
Minimum ambient temperature: 34°F (1°C)
Maximum ambient temperature: 122°F (50°C)
Calcite Filters:
10" X 47", 2 cubic ft. 7.4 gpm
MODEL NO.MINERAL TANK SIZEMEDIA CUBIC FOOTGRAVEL (LBS)SERVICE FLOW*
(GPM)
PWSYS-WHYU-GAC-2CUFT10" X 47"2307.4<1517" X 13" X 60"
*Note: Peak service flow rate is for intermittent use only and is not to be interpreted as continuous service flow rate capability. These systems are designed to treat the domestic water used in a
single family dwelling. For irrigation water treatment or higher volume applications please contact your Watts representative.
Installation and Start-up
OUT
Treated Water
IN
Cold Water
1. Place the system in the desired location.
2. Connect the cold water supply to the inlet of the system.
3. Place a bucket under the outlet port or run a line from the outlet
port to a drain.
5. Slowly open the supply valve (user supplied) to the system. Allow
the tank to fill with water. The initial water will come out black.
Close the supply valve when a steady stream of clear water
comes out of the outlet port.
6. Connect the outlet of the system to the cold water supply of the
building.
7. Open the supply valve to the system.
8. Open faucets downstream from the system to relieve any air.
9. Check for leaks. Repair as needed.
10. The system is now ready for service.
PRESSURE DROP
(PSI)
FLOOR SPACE LXWXH
Bypass Valve Modication
Service Position.
Bypass Position.
3
WARNING: This product contains chemicals known to the
State of California to cause cancer and birth defects or
other reproductive harm.
For more information: www.watts.com/prop65
LIMITED WARRANTY: Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s
warranty only. For specific product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such warranties are exclusive and
are the only remedies for breach of warranty. EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY, IF ANY, WATTS MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. TO THE FULLEST EXTENT
PERMITTED BY APPLICABLE LAW, WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND IN NO EVENT SHALL WATTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR
INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR PROPERTY DAMAGE, REGARDLESS OF WHETHER IT WAS INFORMED ABOUT
THE POSSIBILITY OF SUCH DAMAGES.