Commercial Water Softening Systems
Connection Size: 3" (80 mm) Flow Rates: Up to 280 gpm (1059 lpm)
Watts Pure Water Series PWS30 and PWS30-2 water soften­ing systems are high efficient conventional cation exchange type water softeners. They are suitable for commercial applica­tions ranging from 300,000 to 1,050,000 grains of hardness removal per tank and flow rates up to 280 gallons per minute (1059 lpm). Where continuous softened water is required PWS30-2 duplex alternating systems can be specified for unin­terrupted service. Regeneration is meter demand initiated. All cycles of regeneration are fully automatic and do not require manual actuation.
Watts Pure Water Series PWS30 and PWS30-2 water soften­ers are designed for point of use or point of entry applications where the benefits of softened water are required. These sys­tems exchange scale-forming calcium and magnesium ions with non scale-forming sodium ions to create soft water for a variety of applications. Steam boiler make up water, water heater pretreatment, reverse osmosis pretreatment, cooling tower make up water, sterilizer make up water, washing, and process water are all common applications for the Watts Pure Water Series PWS30 water softeners.
Softened water provides a wide variety of benefits from not introducing scale into pipes, valves, water heating equipment, heat exchangers, and cooling towers to reducing mineral build up in areas that see excessive splashing such as food prepara­tion counters and sink areas. Softened water also conserves soaps and cleaning agents by eliminating the formation of soap curd, so your cleaners can work on cleaning – not reacting with the hardness in your water.
Features
• WQA Certified fully automatic metered demand control valve
• Sophisticated digital electronic controls that store operating
history that can be accessed by the user
• Fully adjustable regeneration cycles
• Durable brass bodied control valve for years of service
• Dry contact lock out switch for remote interface is standard
• WQA Certified high capacity resin
• Highly corrosion resistant NSF Certified fiberglass tanks
• Durable polypropylene lower distribution system
Contractor
Contractor’s P.O. No.
Representative
––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––
PURE WATER
Series PWS30 Series PWS30-2
Standards
Control Valve- WQA Certified to NSF/ANSI Std. 61 Ion Exchange Resin- WQA Certified to NSF/ANSI Std. 44 Mineral Tank- NSF Certified to ANSI Std. 44 or 61
Specifications
A Watts Pure Water Series PWS30 water softening system
shall be installed on the building’s main water line just after
it enters the building. The installation point shall be after any backflow prevention or pressure regulating valves. Other instal-
lation options are to install a system just before the water
heater or other types of equipment needing the protection of
softened water. In installations where dedicated cold water
make up to a water heater is the installation point, a backflow preventer and a thermal expansion tank must be installed as well. The system shall be installed with a bypass valve to allow for the shut down and removal of the unit without interrupting the water supply to the building.
The water softener shall be a down flow regenerated, metered demand, sodium cycle cation exchange type system with all components necessary for proper operation. Electrical require-
ments are 120 volt 60 hertz. A local drain is required to accept
drain water from the system. The feed water pressure must not fall below 25psi or exceed 125psi. Water temperature must not
fall below 34°F or exceed 110°F (1°C - 43°C).
The system shall provide softened water measuring less than one grain per gallon of hardness as Calcium Carbonate when operated within the manufacturers operational specifications.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with­out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Feed Water Guidelines
pH ....................... 6 to 10
Hardness (maximum) ......... Depends on customers acceptable
hardness leakage level.
Water Pressure ............. 25psi to 125psi (171 kPa to 8.5 bar)
Temperature ............... 34 - 110°F (1 - 43°C)
Free Chlorine (maximum) ...... 1mg/L
Iron (maximum) ............. 1mg/L
Oil and H2S ................ None Allowed
Turbidity Less than 5.0 NTU
For all other guideline information please contact your Watts rep­resentative.
Dimensions - Weight
E
E
D
D
Note: Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the system.
PWS30-2 SeriesPWS30 Series
E
E
D
D
F
F
C
C
FRONT
FRONT
MODEL NO. DIMENSIONS WEIGHTS
A B C D E F G
in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs kgs
B
B
G
G
SIDE
SIDE
C
C
A
A
F
F
FRONT
FRONT
B
B
G
G
SIDE
SIDE
PWS30151H11 797/16 2017 797/16 2017 951/4 2419 241/2 622 241/2 622 30 762 50 1270 1070 486
PWS30151I11 PWS30151J11 87 PWS30151K11 95 PWS30151L11 99 PWS30151H21 79
PWS30151I21 PWS30151J21 87 PWS30151K21 95 PWS30151L21 99
817/16 2068 817/16 2068 963/4 2457 301/8 765 301/8 765 39 991 48 1219 1600 727
1
/4 2216 871/4 2216 101 2565 361/8 917 361/8 917 39 991 60 1524 2015 916
1
/4 2419 951/4 2419 108 2743 44 1118 44 1118 42 1067 60 1524 3245 1475
5
/8 2530 995/8 2530 1123/8 2854 503/8 1280 503/8 1280 50 1270 60 1524 4295 941
7
/16 2017 797/16 2017 951/4 2419 241/2 622 85 2159 30 762 50 1270 2070 941
817/16 2068 817/16 2068 963/4 2457 301/8 765 100 2540 39 991 48 1219 3000 1364
1
/4 2216 871/4 2216 101 2565 361/8 917 111 2819 39 991 60 1524 4015 1325
1
/4 2419 951/4 2419 108 2743 44 1118 126 3200 42 1067 60 1524 6245 2839
5
/8 2530 995/8 2530 1123/8 2854 503/8 1280 150 3810 50 1270 60 1524 8295 3770
A
A