DEEP WELL PUMP
CONTROL VALVE
01/05
Mustang Series
M1513-6 or M61513-6 (Angle)
Operation
The Watts ACV Deep Well Pump Control Valve is designed to minimize the surges associated with the
starting and stopping of well pumps. The valve slowly opens and closes as required to control pumping
related surges. The pump starts and stops against an open valve.
Pump start up: When the pump is signaled to start, the 4-Way Solenoid is energized and directs fluid and
pressure into the cover chamber (above the diaphragm), and relieves fluid and pressure from the power
chamber (below the diaphragm). The fluid and pressure relieved from the cover chamber is vented to
atmosphere or available floor drain. The valve closes at an adjustable rate, gradually admitting pumping
pressure into the distribution system. Rate of valve closure is controlled by the adjustable closing speed
control, which restricts the speed at which fluid and pressure evacuate the power chamber. The valve
remains closed during the pumping cycle.
Pump shutdown: When the pump is signaled to shut-off, the 4-Way Solenoid is de-energized, and directs
fluid and pressure into the power chamber (below the diaphragm), and relieves fluid and pressure from the
cover chamber (above the diaphragm). The fluid and pressure relieved from the cover chamber is vented
to atmosphere or available floor drain. The valve opens at an adjustable rate, gradually reducing pumping
pressure, allowing the system check valve to slowly close. Rate of valve opening is controlled by the
adjustable opening speed control, which restricts the speed at which fluid and pressure evacuate the cover
chamber. When the valve reaches the full open position, the limit switch is actuated, turning the pump off.
M513-6 or M6513-6 (Globe)
Manual Operation: Engaging the Solenoid Manual operator simulates power to the solenoid, manually
closing the main valve. Disengaging the Solenoid Manual operator returns the valve to the open position.
8550 Hansen Road • Houston, Texas 77075 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.wattsacv.com
DEEP WELL PUMP
CONTROL VALVE
01/05
Mustang Series
M1513-6 or M61513-6 (Angle)
Installation Guidelines
M513-6 or M6513-6 (Globe)
• Prior to installation, flush line to remove debris.
• Install valve horizontally “in line” (cover facing UP), so flow arrow matches flow through the line. Avoid
installing valves 6” and larger vertically. Consult factory prior to ordering if installation is other than
described.
• Install inlet and outlet isolation valves. NOTE: When using butterfly valves, insure disc does not contact
control valve. Damage or improper valve seating may occur.
• Provide adequate clearance for valve servicing and maintenance.
• Provide adequate drain for cover chamber and power chamber discharge. Consult “Valve Cover
Capacity” chart on appropriate main valve Engineering Bulletin.
• Install pressure gauges to monitor valve inlet and outlet pressure.
• Connect Solenoid and Limit Switch to appropriate pump control panel locations and power source in
compliance with local electrical codes.
Other Watts ACV Pump Control Valves
M113-21 / M6113-21 Pump Control Valve
M113-19 / M6113-19 Pump Control Valve with Backpressure Feature
M113-29 / M6113-29 Pump Control Valve with Pressure Reducing Feature
M113-41 / M6113-41 Pump Control Valve with Rate-of-Flow Feature
M513-5 / M6513-5 Pump Control Valve
M513-AK / M6513-AK Pump Control Valve with High Capacity Pilot System
M513-14 / M6513-14 Deep Well Pump Control Valve with Pressure Relief Feature
8550 Hansen Road • Houston, Texas 77075 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.wattsacv.com