For Industrial Process Applications
ES-LF560_LFH560
Job Name
Job Location
Engineer
Approval
–––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
LEAD FREE
*
Contractor
Approval
Contractor’s P.O. No.
Representative
Series LF560, LFH560
Mini Water Pressure Reducing
Valves**
Sizes: 1⁄8", 1⁄4" & 3⁄4" Male x 3⁄4" Female
(3, 8 & 20 x 20mm) Hose Connection
Series LF560, LFH560 Mini Water Pressure Reducing Valves are
designed to reduce incoming water pressure to a sensible level
to protect plumbing system components and reduce water consumption. This series is ideal where a small economical package is
required such as on special industrial process applications, miscellaneous plumbing applications and OEM equipment. Series LF560
and LFH560 are suitable for water supply pressures up to 300psi
(21 bar). The LF560, LFH560 features Lead Free* construction to
comply with Lead Free* installation requirements.
––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––
A
C
D
LF560
B
Features
• Rugged Lead Free* brass body
• Stainless steel stem and spring
• Oversized orifices
• Comes standard with 1⁄8" (3mm) gauge port (plugged)
• Heavy duty adjusting screw. Adjusting screw is both
slotted and knurled.
Models
LF560 Female threaded inlet x female threaded outlet
LFH560 Female hose connection inlet x male hose connection
outlet for grid systems. Also used on recreational vehicles.
Options
G gauge
Specifications
A Mini Water Pressure Reducing Valve shall be installed where
indicated on the plans. Lead Free* Mini Water Pressure Reducing
Valves shall be constructed using Lead Free* materials. Lead
Free valves shall comply with state codes and standards, where
applicable, requiring reduced lead content. Valve shall have a
Lead Free* brass body and stainless steel stem and spring. Valve
shall come standard with a
Series LF560 (threaded), LFH560 (hose connection).
*The wetted surface of this product contacted by consumable
water contains less than 0.25% of lead by weight.
** A water saving test program concluded that reducing the
supply pressure from 80 – 50psi (551 – 346 kPa) resulted in a
water savings of 30%.
1
⁄8" gauge port. Valve shall be a Watts
A
LFH560G
Dimensions – Weights
MODEL DIMENSIONS WEIGHTS
A B C D
in. mm in. mm in. mm in. mm oz. kgs.
LF560 11⁄2 38 1⁄8 3 2 51 1⁄2 12.7 4.75 .14
LF560G 1
LFH560 3 76
LFH560G 3 76
1
⁄2 38 1⁄8 3 2 51 1⁄2 12.7 6.50 .18
1
⁄8 3 2 51 1⁄2 12.7 5.50 .16
1
⁄8 3 2 51 1⁄2 12.7 7.25 .21
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials
without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Materials
Body: Lead Free* brass
Seat: Buna-N
Diaphragm: Buna-N
Stem: Stainless Steel
Spring: Stainless Steel
Capacity
Reduced pressure range: 0 – 25psi (0 – 1.7 bar)
Initial pressure: 100psi (6.9 bar)
bar psi
4.1 60
3.4 50
Pressure – Temperature
LF560
Temperature Range: 33°F – 140°F (.6°C – 60°C)
Maximum Working Pressure: 300psi (21 bar)
Reduced Pressure Range:
Range Std. set at
Suffix psi bar psi bar
A 0 – 25 0 – 1.7 15 1.0
B 0 – 60 0 – 4.1 40 2.8
C 0 – 125 0 – 8.6 80 5.6
LFH560
Temperature Range: 33°F – 140°F (.6°C – 60°C)
Maximum Working Pressure: 150psi (10.3 bar)
Adjustable Reduced Pressure Range: 10 – 60psi
(68.9 – 413.7 kPa)
Standard Reduced Pressure Setting: 40psi (276 kPa)
Delivery Capacity up to 250 gallons per hour
2.8 40
2.1 30
1.4 20
Reduced Pressure
.7 10
.0 0
Flow
1
3.8
Reduced pressure range: 0 – 60psi (0 – 4.1 bar)
Initial pressure: 100psi (6.9 bar)
bar psi
4.1 60
3.4 50
2.8 40
2.1 30
1.4 20
Reduced Pressure
.7 10
7.6
2
gpm
lpm
.0 0
Flow
1
3.8
Reduced pressure range: 0 – 125psi
Initial pressure:
bar psi
8.6 125
6.9 100
5.2 75
3.4 50
Reduced Pressure
1.7 25
.0 0
100 – 150psi (6.9 – 10.3 bar)
I.P. 150psi
I.P. 150/100psi
I.P. 150/100psi
Flow
1
3.8
(0 – 8.6 bar)
I.P. 150psi
I.P. 150/100psi
2
7.6
7.6
2
gpm
lpm
gpm
lpm
A Watts Water Technologies Company
ES-LF560_LFH560 1323 © 2013 Watts
USA: Tel. (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com