Watts LFCS User Manual

For Mixing Tempering Valve Applications
ES-LFCS
Job Name
Job Location
Engineer
Approval
LEAD FREE
–––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
*
Model LFCS
Check Stop Valves
Sizes: 1⁄2"
Model LFCS check stop valves are designed for use at the hot and cold water inlet sup plies for mixing and tem per ing valves. Model LFCS valves perform triple duty as: 1) iso la tion valves,
Model LFCS valve protects against cross flow of hot and cold water in the system and provide isolation of the mixing or tem per ing valve during ser vic ing and main te nance of the valve and strain er. The integral fine strainer protects the valve from dam ag ing dirt and other debris.The Model LFCS valve features Lead Free* construction to comply with Lead Free* installation requirements.
Contractor
Approval
Contractor’s P.O. No.
Representative
––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––
LFCS-T-UT
Features
• Performs triple duty as: 1) check valve, 2) shutoff valve, and 3) strainer
• Check valve function protects against hot and cold water supply cross flow
• Shut-off function facilitates mixing valve ser vice and strainer maintenance
• Strainer protects mixing valves from dirt and other debris
• Universal design eliminates left-hand/right-hand confusion
Materials
Body: Lead Free* Copper Silicon Alloy O-rings: EPDM Strainer: Stainless steel Spring: Stainless steel Disc: EPDM Stem: Lead Free* Brass
Specifications
LFCS combination check/stop/strain er valve shall be used at the
hot and cold wa ter inlets to the Watts LFL111 and LFMMV mix ing valves. The combination check stop valve(s) shall be a Watts model LFCS, as in di cat ed on the installation plans. The combination check stop valve shall be of lead free con struc tion. Lead Free* check stop shall comply with state codes and standards, where applicable, requiring reduced lead content. The check stop valve shall be fit ted with a strainer to pre vent large par tic u late mat ter from entering the valve. The check stop valve shall be fitted with a union con nec tion to fa cil i tate the re mov al of the mixing valve and the ser vic ing of the strain er. The check stop valve inlet connection shall be threaded
(-T). The outlet connection shall be threaded (-UT). The check/stop/
strainer valve(s) used shall be the Watts LFCS Check Stop valve.
Pressure – Temperature
Maximum Working Pressure: 150psi (10.3 bar) at 225°F (107°C)
*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with­out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Installation
Alternate
Model LFCS (2 required)
Cold W
ater
Supply
Hot Supply
Piping
Strainer
Check
Valve
Isolation Ball Valve
Hot
Isolation Ball Valve (optional)
To Fixture
LFL111
Model LFCS (2 required)
Cold
Hot
To Fixture
LFMMV
Cold
Hot Water
Supply
Watts LF1170F
or LFN170
mixing valve
(optional)
Isolation Ball Valve (optional)
Dimensions – Weight
B
D
LFCS-T-UT
SizE (DN) moDEl iNlEt outlEt DimENSioNS WEightS uNioN
A B D E Inlet Outlet
in. in. mm in. mm in. mm in. mm in. mm oz. gr.
CS-T-UT
1
1
2
2 15 27⁄8 73 15⁄16 59 13⁄16 30 21⁄4 57 12 340 FNPT MNPT
E
A
A Watts Water Technologies Company
USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca
ES-LFCS 1335 © 2013 Watts