Watts LF8 User Manual

For Health Hazard Applications
ES-LF8
Job Name
Job Location
Engineer
Approval
LEAD FREE
–––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
*
Series LF8
Hose Connection Vacuum Breakers
Size: 3⁄4" hose thread
Series LF8 can be used on a wide variety of installations, such as service sinks, swimming pools, photo developing tanks, laundry tubs, wash racks, dairy barns, marinas and general outside gar­dening uses.
Contractor
Approval
Contractor’s P.O. No.
Representative
––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––
LF8A
Non-Removable Model
LFNF8
Permits Manual Drain
8P
Tamper-Proof Feature
––––––––––––––––––––––––––––––––––
LF8
LF8B
Features
• Copper silion alloy body (all models except 8P, which is plastic)
• Stainless steel working parts for longevity
• Durable rubber diaphragm and disc for
consistent positive seating
Models
LF8A - Furnished with exclusive “Non-Removable” feature and
standardly equipped to allow sill cock to be drained.
NOTICE
Device should only be installed on approved sill cocks containing at least four full threads. Non-removable once installed.
LF8 - Similar to the 8A except it is furnished without the “Non-Removable” or draining feature. Secured with Allen
head set screw. LF8B - Furnished with break-away set screw to provide a
tamper-resistant installation. Standardly equipped to allow sill cock to be drained.
LFNF8 - Especially made for wall and yard hydrants. Permits man- ual draining for freezing conditions.
8P - Furnished with exclusive patented “Non-Removable” feature. Standardly equipped to allow sill cock to be drained. Constructed of durable, corrosion-resistant, reinforced thermoplastic. Tamper-proof feature.
LF8AC, LF8C or LF8BC - Same as above but furnished with chrome finish.
LF8FR - With freeze relief feature.
LF8FR
NOTICE
Series LF8 is tested and certified under ANSI A112.1.3 (ASSE 1011), which precludes use under continuous pressure.
This valve should only be used in areas where spillage of water will not cause damage.
3
Inlet Connection: Outlet Connection: Maximum Pressure: 125psi (8.6 bar) Maximum Temperature: 180°F (82°C)
For backflow preventers for tub and shower hand spray sets, request literature ES-S8.
4" standard female hose thread
3
4" standard male hose thread
Specifications
A hose connection type anti-siphon vacuum breaker shall be installed where indicated on the plans to prevent the backsiphon­age of contaminated water. Lead Free* hose connection vacuum breaker shall be constructed using Lead Free* materials. Lead Free vacuum breaker shall comply with state codes and standards, where applicable, requiring reduced lead content. This device is not to be used under continuous pressure or where there is a possibil­ity that a backpressure condition may develop. This device shall
meet the requirements of ANSI A112.1.3, ASSE Standard 1011.
Vacuum breaker shall be a Watts Series LF8.
*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with­out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Capacity
Installations
kPa psi
276 40
241 35
207 30
172 25
138 20
103 15
Supply Pressure
69 10
35 5
0 1 2 3 4 5 6 7 8 9 10 gpm
0 3.8 7.6 11.4 15.1 18.9 23 27 30 34 38 lpm
**Performance as established by an independent testing laboratory.
Performance** Curve
Flow
Approvals
1011 B64.2
Series LF8, LF8A, LF8B, 8P, LF8FR and LFNF8 are listed by IAPMO.
NOTICE
Inquire with governing authorities for local installation requirements
For Inside or Outside Use
Installation - Inside Service Sink
Hose Bibb
Vacuum Breaker
What is Backsiphonage?
A reversal of normal flow in the system caused by a negative pressure (vacuum or partial vacuum) in the supply piping.
Hose Bibb
Vacuum Breaker
Drainage Features to Prevent Freezing
Models LF8A, LF8B, LF8FR and 8P hose connection vacuum
breakers are constructed to allow sill cocks to be drained. Simply remove hose coupling and lightly pull knurled tip of stem at outlet of valve to allow drainage of collected water.
Dimensions – Weights
B
A
MODEL SIZE DIMENSIONS WEIGHT
A B
In. In. mm In. mm oz. gm.
LF8, LF8C, LF8B, LF8BC 3⁄4 HT 11⁄2 38 13⁄8 35 4.0 113.4 LF8A, LF8AC 3⁄4 HT 11⁄2 38 11⁄2 38 4.0 113.4 LFNF8 3⁄4 HT 2 51 11⁄2 38 5.3 151.2 8P 3⁄4 HT 13⁄4 38 13⁄8 35 1.5 42.5 LF8FR 3⁄4 HT 13⁄4 38 13⁄4 38 7.0 200.0
NOTICE
Do not use Models LF8, LF8A, LF8B, 8P, LF8FR Hose Bibb Vacuum Breakers on frost-free hydrants. Specify Model LFNF8.
Do not use where discharge of water is objectionable.
A Watts Water Technologies Company
ES-LF8 1331 © 2013 Watts
USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca