INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure.
Save manual for future reference
Whole House Filtration
Model: 500221
Watts Premier • 8716 West Ludlow Drive • Peoria AZ • 85381
1-800-752-5582 • www.premierH2o.com
Rev. Date 04/08/2011 Manual # 199031
Watts Premier’s Whole House Filtration with pressure relieve valve
Watts Premier’s Whole House Filtration system should be installed on the main cold water line servicing the house and installed in location that is protected of the environment.
Watts Premier does not take any responsibility for the plumbing of the system into the
water line. Install accordingly to your local plumbing codes.
Watts Premier’s Whole House Filtration system comes with one inch ttings. If your
water line is smaller than one inch you will need to use proper reducers for the installation
(not included).
Note: Only Teon tape should be used on threaded ttings, do not use pipe dope as it may
cause damage to the plastic threads.
Operational Parameters:
1. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
2. Operating Temperatures:
Maximum 100F (37.8C)
Minimum 40F (04.4C)
3. Operating Pressures:
Maximum 85 PSIG (5.95 kg/cm2)
Minimum 5 PSIG (0.35 kg/cm2)
4. Maximum Flow Rate:
22 GPM @ 60 psig
83.27 LPM @ 4.20 kg/cm2
Installation Tools & Materials Recommended:
For Typical Installation:
- Pipe Cutter or Hack Saw
- 1/2” Open-end Wrench & Adjustable Pipe Wrench
- Variable Speed Drill
- Teon Tape (Supplied)