MODEL 2900s - Downflow & Upflow
Service Manual
IMPORTANT: Fill in pertinent information on page 4 for future reference.
MODEL 2900s
Table of Contents
Job Specification Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3200 Timer Setting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3210 Timer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Regeneration Cycle Program Setting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Environmental Power Head. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Lower Environmental Power Head. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Designer Power Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Lower Designer Power Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Control Valve Body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1600 Brine System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
1650 Brine System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1700 Brine System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1710 Brine System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Regulation Assembly 1600/1700 - Upflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
1600/1700 System Nozzle & Throat Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2” Brass Meter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2” Plastic Meter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2300 Safety Brine Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
2310 Safety Brine Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2350 Safety Brine Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Service Valve Operator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Control Valve Side Mount Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Service Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Service Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Service/Backwash/Brine Positions (Downflow) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Slow Rinse/Rapid Rinse/Brink Tank Fill Positions (Downflow). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Service/Brine/Slow Rinse Positions (Upflow) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Back Wash/Rapid Rinse/Brink Tank Fill Positions (Upflow) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Tank with Pressure Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Flow Data & Injector Draw Rates (Downflow) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Environmental Backplate Line Drawing/Distributor Cut Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Designer Backplate Line Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
System #4 - Typical Single Tank Installation with Optional Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
System #5 - Interlock - Typical Twin Tank Installation with Optional Meter Interlock
and No Hard Water Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
System #6 - Twin Series Regeneration System #7 - Twin Alternator Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
System #4 - Single Valve Regeneration Immediate and Delayed Valve Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
System #4 - With Remote Signal Start Valve Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
System #5 - Interlocked Regeneration Valve Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
System #6 - Series Regeneration Valve Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
System #7 - Alternating Regeneration Valve Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
System #7 - Alternating Regeneration Multi-Valve System Valve Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
IMPORTANT: The information, specifications and illustrations in this manual are based on the latest information available
at the time of printing. The manufacturer reserves the right to make changes at any time without notice.
MODEL 2900s
Job Specification Sheet
• JOB NO._________________________________________________________________
• MODEL NO. _____________________________________________________________
• WATER TEST ____________________________________________________________
• CAPACITY PER UNIT ______________ MAX. ____________ PER REGENERATION
• MINERAL TANK SIZE DIA. ________ HEIGHT __________
• BRINE TANK SIZE & SALT SETTING PER REGENERATION:
________________________________________________________________________
• 2900 CONTROL VALVE SPECIFICATIONS
1) Type of Timer (see pages 10-13)
A) 7 day or 12 day
B) * 1,250 to 21,250 gallon meter or
* 6,250 to 106,250 gallon meter
* Other ______________________________________________________
C) Meter Wiring Package
1) System #4 - 1 tank; 1 meter; immediate or delayed regeneration
2) System #5 - 2 tanks; 2 meters; interlock
3) System #6 - 2 tanks; 1 meter; series regeneration
4) System #7 - 2 tanks; 1 meter; alternator
2) Timer Program Settings (see pages 6-9)
A) Backwash ______________________________ min.
B) Brine & Slow Rinse ______________________ min.
C) Rapid Rinse ____________________________ min.
D) Brine Tank Refill_________________________ min.
3) Drain Line Flow Controller _________________________
4) Brine Line Flow Controller ___________________________
5) Injector Size # _____________________________________
6) A) Hard Water By-Pass
B) No Hard Water By-Pass
Page 4
MODEL 2900s
General Commercial Pre-Installation Check List
WATER PRESSURE: A minimum of 20 pounds of water pressure is required for regeneration valve to operate effectively.
ELECTRICAL FACILITIES: A continuous 110 volt, 60 Hertz current supply is required. Make certain the current supply is
always hot and cannot be turned off with another switch.
EXISTING PLUMBING: Condition of existing plumbing should be free from lime and iron buildup. Piping that is built up heavily with lime and/or iron should be replaced. If piping is clogged with iron, a separate iron filter unit should be installed ahead of the water softener.
LOCATION OF SOFTENER AND DRAIN: The softener should be located close to a drain.
BY-PASS VALVES: Always provide for the installation of a by-pass valve.
CAUTION: Water pressure is not to exceed 120 p.s.i., water temperature is not to exceed 100° F, and the unit cannot be subjected
to freezing conditions.
Installation Instructions
1. Place the softener tank where you want to install the unit making sure the unit is level and on a firm base.
2. All plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be the same size as the drain line flow control female connection. Water meters are to be installed on soft water outlets. Twin units with (1) one meter shall be installed on common soft water outlet of units.
3. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting. Leave at least 6” between the DLFC and solder joints when soldering when the pipes are connected on the DLFC. Failure to do this could cause interior damage to the DLFC.
4. Teflon tape is the only sealant to be used on the drain fitting. The drain from twin units may be run through a common line.
5. Make sure that the floor is clean beneath the salt storage tank and that it is level.
6. Place approximately 1 of water above the grid plate (if used) in your salt tank. Salt may be placed in the unit at this time.
7. On units with a by-pass, place in by-pass position. Turn on the main water supply. Open a cold soft water tap nearby and let run a few minutes or until the system is free from foreign material (usually solder) that may have resulted from the installation.
8. Place the by-pass in service position.
9. Manually index the softener control into “service” position and let water flow into the mineral tank. When water flow stops, open a cold water tap nearby and let run until air pressure is relieved.
10. Electrical: All electrical connections must be connected according to codes. Use electrical conduit if applicable. Remote meter systems and Twin meter system wiring diagrams can be found at the back of the service manual.
11. Plug into power supply.
Page 5
MODEL 2900s
3200 Timer Setting Procedure
How To Set Days On Which Water Conditioner Is To Regenerate:
Rotate the skipper wheel until the number “1” is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to expose trip fingers. Each tab is one day. Finger at red pointer is tonight. Moving clockwise from the red pointer, extend or retract fingers to obtain the desired regeneration schedule.
How To Set The Time Of Day:
Press and hold the red button in to disengage the drive gear.
Turn the large gear until the actual time of day is at the time of day pointer.
Release the red button to again engage the drive gear.
How To Manually Regenerate Your Water Conditioner At Any Time:
Turn the manual regeneration knob clockwise.
This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program.
The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing.
Even though it takes three hours for this center knob to complete one revolution, the regeneration cycle of your unit might be set only one half of this time.
In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line.
SERVICE POSITION INDICATOR
RED TIME SET BUTTON
24 HR. GEAR
MANUAL REGENERATION KNOB
SKIPPER WHEEL, 12 DAY (SHOWS EVERY OTHER DAY REGENERATION)
How to Adjust Regeneration Time:
1. Disconnect the power source.
2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration knob.
3. Loosen each screw slightly to release the pressure on the time plate from the 24 hour gear.
4. Locate the regeneration time pointer on the inside of the 24 hour dial in the cut out.
5. Turn the time plate so the desired regeneration time aligns next to the raised arrow.
6. Push the red button in and rotate the 24 hour dial. Tighten each of the three screws.
7. Push the red button and locate the pointer one more time to ensure the desired regeneration time is correct.
8. Reset the time of day and restore power to the unit.
Page 6
3200 ADJUSTABLE REGENERATION TIMER
MODEL 2900s
3210 Timer Settings
Typical Programming Procedure
Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the gallons available opposite the small white dot on the program wheel gear. Note, drawing shows 8,750 gallon setting. The capacity (gallons) arrow denotes remaining gallons exclusive of fixed reserve.
How To Set The Time Of Day:
Press and hold the red button in to disengage the drive gear.
Turn the large gear until the actual time of day is opposite the time of day pointer.
Release the red button to again engage the drive gear.
MANUAL REGENERATION
* 24 HOUR GEAR
KNOB
How To Manually Regenerate Your Water Conditioner At Any Time:
Turn the manual regeneration knob clockwise.
This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program.
The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing.
Even though it takes three hours for this center knob to complete one revolution, the regeneration cycle of your unit might be set for only one half of this time.
In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line.
Immediate Regeneration Timers:
These timers do not have a 24 hour gear. Setting the gallons on the program wheel and manual regeneration procedure are the same as previous instructions.
SERVICE POSITION INDICATOR
PROGRAM WHEEL
RED TIME SET BUTTON
WHITE DOT
* Immediate regeneration timers do not have 24 hour gear. No time of day can be set.
GALLONS LABEL
NOTE:
To set meter capacity rotate manual knob one
- 360° revolution to set gallonage.
Page 7
MODEL 3200 & 3210 TIMER SERIES
Regeneration Cycle Program Setting Procedure - Downflow
(Brine Tank Refill Separate From Rapid Rinse)
How To Set The Regeneration Cycle Program:
The regeneration cycle program on your water conditioner has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions.
3200 & 3210 Series Timers (Figure to Right)
To expose cycle program wheel, grasp timer in upper left-hand corner and pull, releasing snap retainer and swinging timer to the right
To change the regeneration cycle program, the program wheel must be removed. Grasp program wheel and squeeze protruding lugs toward center, lift program wheel off timer. (Switch arms may require movement to facilitate removal.)
Return timer to closed position engaging snap retainer in back plate. Make certain all electrical wires locate above snap retainer post
Timer Setting Procedure for 3200 & 3210 Timer
How To Change The Length Of The Backwash Time:
The program wheel as shown in the drawing is in the service position. As you look at the numbered side of the program wheel, the group of pins starting at zero determines the length of time your unit will backwash.
FOR EXAMPLE: If there are six pins in this section, the time of backwash will be 12 min. (2 min. per pin). To change the length of backwash time, add or remove pins as required. The number of pins times two equals the backwash time in minutes.
How To Change The Length Of Brine And Rinse Time:
The group of holes between the last pin in the backwash section and the second group of pins determines the length of time that your unit will brine and rinse (2 min. per hole.)
To change the length of brine and rinse time, move the rapid rinse group of pins to give more or fewer holes in the brine and rinse section. Number of holes times two equals brine and rinse time in minutes.
How To Change The Length Of Rapid Rinse:
The second group of pins on the program wheel determines the length of time that your water conditioner will rapid rinse. (2 min. per pin.)
BRINE & RINSE SECTION (2 MIN. PER HOLE)
PIN STORAGE
BACKWASH SECTION (2 MIN. PER PIN)
PROGRAM WHEEL FOR CONTROL OF REGENERATION CYCLE
RAPID RINSE SECTION (2 MIN. PER PIN)
BRINE TANK
REFILL SECTION
(2 MIN.
PER HOLE)
To change the length of rapid rinse time, add or remove pins at the higher numbered end of this section as required. The number of pins times two equals the rapid rinse time in minutes.
How To Change The Length Of Brine Tank Refill Time:
The second group of holes in the program wheel determines the length of time that your water conditioner will refill the brine tank (2 min. per hole.)
To change the length of refill time, move the two pins at the end of the second group of holes as required.
The regeneration cycle is complete when the outer microswitch is tripped by the two pin set at end of the brine tank refill section.
The program wheel, however, will continue to rotate until the inner micro-switch drops into the notch on the program wheel.
Page 8
MODEL 3200 & 3210 TIMER SERIES
Regenerating Cycle Program Setting Procedure - Upflow
(Brine Draw First)
How To Set The Regeneration Cycle Program:
The regeneration cycle program on your water conditioner has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions.
3200 & 3210 Series Timers (Figure to Right)
To expose cycle program wheel, grasp timer in upper left-hand corner and pull, releasing snap retainer and swinging timer to the right
To change the regeneration cycle program, the program wheel must be removed. Grasp program wheel and squeeze protruding lugs toward center, lift program wheel off timer. (Switch arms may require movement to facilitate removal.)
Return timer to closed position engaging snap retainer in back plate. Make certain all electrical wires locate above snap retainer post
Timer Setting Procedure for 3200 & 3210 Timer
How To Change The Length Of The Backwash Time:
The program wheel as shown in the drawing is in the service position. As you look at the numbered side of the program wheel, the group of pins starting at zero determines the length of time your unit will backwash.
How To Change The Length Of Rapid Rinse:
The second group of pins on the program wheel determines the length of time that your water conditioner will rapid rinse. (2 min. per pin.)
To change the length of rapid rinse time, add or remove pins at the higher numbered end of this section as required. The number of pins times two equals the rapid rinse time in minutes.
How To Change The Length Of Brine Tank Refill Time:
The second group of holes in the program wheel determines the length of time that your water conditioner will refill the brine tank (2 min. per hole.)
To change the length of refill time, move the two pins at the end of the second group of holes as required.
The regeneration cycle is complete when the outer microswitch is tripped by the two pin set at end of the brine tank refill section. The program wheel, however, will continue to rotate until the inner micro-switch drops into the notch on the program wheel.
FOR EXAMPLE: If there are six pins in this section, the time of backwash will be 12 min. (2 min. per pin). To change the length of backwash time, add or remove pins as required. The number of pins times two equals the backwash time in minutes.
How To Change The Length Of Brine And Rinse Time:
The group of holes between the last pin in the backwash section and the second group of pins determines the length of time that your unit will brine and rinse (2 min. per hole.)
To change the length of brine and rinse time, move the rapid rinse group of pins to give more or fewer holes in the brine and rinse section. Number of holes times two equals brine and rinse time in minutes.
Page 9
MODEL 2900s
3200 Timer Assembly
(See opposite page for parts list)
29
12
31
32
1
30
10
9
2
3
4
5
6
7
8
5
11
13
23
24
25
26
25
16
27
17
25
14
15
5
18
19
20
28
21
22
Page 10
MODEL 2900s
3200 Timer Assembly
Parts List
Item No. Quantity Part No. Description
1 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 13870. . . . . . . . . . . . . . . . . . Housing, Timer, 3200
2 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 13011. . . . . . . . . . . . . . . . . . Arm, Cycle Actuator
3 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 40096-24 . . . . . . . . . . . . . . . Dial 12AM Regen Assy, Black
40096-02 . . . . . . . . . . . . . . . Dial 2AM Regen Assy, Black
4 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 13886. . . . . . . . . . . . . . . . . . Knob, 3200
5 . . . . . . . . . . . . 5 . . . . . . . . . . . . . 13296. . . . . . . . . . . . . . . . . . Screw, Hex Wsh, 6-20 x 1/2 Type 25 Steel Zinc
6 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 11999. . . . . . . . . . . . . . . . . . Label, Button
7 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 14381. . . . . . . . . . . . . . . . . . Skipper Wheel Assy, 12 Day
14860. . . . . . . . . . . . . . . . . . Skipper Wheel Assy, 7 Day
8 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 13014. . . . . . . . . . . . . . . . . . Pointer, Regeneration
9 . . . . . . . . . . . . 1 . . . . . . . . . . . . . 14265. . . . . . . . . . . . . . . . . . Clip, Spring
10 . . . . . . . . . . . 2 . . . . . . . . . . . . . 13311. . . . . . . . . . . . . . . . . . Spring, Detent, Timer
11. . . . . . . . . . . . 2 . . . . . . . . . . . . . 13300. . . . . . . . . . . . . . . . . . Ball, 1/4” SS
12 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15424. . . . . . . . . . . . . . . . . . Spring, Detent, Timer
13 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13911. . . . . . . . . . . . . . . . . . Gear, Main Drive, Timer
14 . . . . . . . . . . . 1 . . . . . . . . . . . . . 19210. . . . . . . . . . . . . . . . . . Program Wheel Assy, 3200
15 . . . . . . . . . . . 21 . . . . . . . . . . . . 15493 . . . . . . . . . . . . . . . . . . Pin, Spring, 1/16 x 5/8 SS
16 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13018. . . . . . . . . . . . . . . . . . Pinion, Idler
17 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13312. . . . . . . . . . . . . . . . . . Spring, Idler Shaft
18 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13017. . . . . . . . . . . . . . . . . . Gear, Idler
19 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13164. . . . . . . . . . . . . . . . . . Gear, Drive
20 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13887. . . . . . . . . . . . . . . . . . Plate, Motor Mounting
21 . . . . . . . . . . . 1 . . . . . . . . . . . . . 18743-1 . . . . . . . . . . . . . . . . Motor, 120V, 60Hz 1/30 RPM, 5600
19659-1 . . . . . . . . . . . . . . . . Motor, 24V, 60 Hz 1/30 RPM
22 . . . . . . . . . . . 2 . . . . . . . . . . . . . 13278. . . . . . . . . . . . . . . . . . Screw, Phil Hd Mach, 6-32 x 1/8 Steel Zinc
23 . . . . . . . . . . . 3 . . . . . . . . . . . . . 11384. . . . . . . . . . . . . . . . . . Screw, Phil, 6-32 x 1/4 Zinc
24 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13881. . . . . . . . . . . . . . . . . . Bracket, Hinge Timer
25 . . . . . . . . . . . 3 . . . . . . . . . . . . . 14087. . . . . . . . . . . . . . . . . . Insulator
26 . . . . . . . . . . . 1 . . . . . . . . . . . . . 10896. . . . . . . . . . . . . . . . . . Switch, Micro
27 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15320. . . . . . . . . . . . . . . . . . Switch, Micro, Timer
28 . . . . . . . . . . . 2 . . . . . . . . . . . . . 11413. . . . . . . . . . . . . . . . . . Screw, Pan Hd Mach, 4-40 x 1 1/8 MS Steel Zinc
29 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14007. . . . . . . . . . . . . . . . . . Label, Time of Day
30 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14045. . . . . . . . . . . . . . . . . . Label, Instruction
31 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13864. . . . . . . . . . . . . . . . . . Ring, Skipper Wheel
32 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15066. . . . . . . . . . . . . . . . . . Ball, 1/4” Delrin
Not Shown . . . . 1 . . . . . . . . . . . . . 13902. . . . . . . . . . . . . . . . . . Harness, 3200
Not Shown . . . . 2 . . . . . . . . . . . . . 40422. . . . . . . . . . . . . . . . . . Nut, Wire, Tan
Not Shown . . . . 1 . . . . . . . . . . . . . 15354-01 . . . . . . . . . . . . . . . Wire, Ground 4”
Page 11
MODEL 2900s
3210 Timer Assembly
(See opposite page for parts list)
1
38
2
3
5
6
7
31
32
33
34
26
35
27
37
36
28
8
9
10
18
19
20
29
7
11
12
13
14
15
16
6
23
21
24
25
Page 12
MODEL 2900s
3210 Timer Assembly
Parts List
Item No. Quantity Part No. Description
1. . . . . . . . . . . . 1 . . . . . . . . . . . . . 13870-01 . . . . . . . . . . . . . . . Housing Assy, Timer, 3210
2. . . . . . . . . . . . 1 . . . . . . . . . . . . . 13802 . . . . . . . . . . . . . . . . . . Gear, Cycle Actuator
3. . . . . . . . . . . . 1 . . . . . . . . . . . . . 40096-24 . . . . . . . . . . . . . . . Dial 12 AM Regen Assy, Black
40096-02 . . . . . . . . . . . . . . . Dial 2 AM Regen Assy, Black
5. . . . . . . . . . . . 1 . . . . . . . . . . . . . 13886 . . . . . . . . . . . . . . . . . . Knob, 3200
6. . . . . . . . . . . . 4 . . . . . . . . . . . . . 13296 . . . . . . . . . . . . . . . . . . Screw, Hex Wsh, 6-20 x 1/2 Type 25 Steel Zinc
7. . . . . . . . . . . . 2 . . . . . . . . . . . . . 11999 . . . . . . . . . . . . . . . . . . Label, Button
8. . . . . . . . . . . . 1 . . . . . . . . . . . . . 60405-50 . . . . . . . . . . . . . . . Program Wheel, w/2” Std Label
9. . . . . . . . . . . . 1 . . . . . . . . . . . . . 13806 . . . . . . . . . . . . . . . . . . Retainer, Program Wheel
10 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13748. . . . . . . . . . . . . . . . . . Screw, Flt Hd St, 6-20 x 1/2 Type 25 316 S.S.
11. . . . . . . . . . . . 1 . . . . . . . . . . . . . 14265. . . . . . . . . . . . . . . . . . Clip, Spring
12 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15424. . . . . . . . . . . . . . . . . . Spring, Detent, Timer
13 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15066. . . . . . . . . . . . . . . . . . Ball, 1/4” Delrin
14 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13911. . . . . . . . . . . . . . . . . . Gear, Main Drive, Timer
15 . . . . . . . . . . . 1 . . . . . . . . . . . . . 19210. . . . . . . . . . . . . . . . . . Program Wheel Assy, 3200
16 . . . . . . . . . . . 21 . . . . . . . . . . . . 15493 . . . . . . . . . . . . . . . . . . Pin, Spring, 1/16 x 5/8 SS
17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
18 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13018. . . . . . . . . . . . . . . . . . Pinion, Idler
19 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13312. . . . . . . . . . . . . . . . . . Spring, Idler Shaft
20 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13017. . . . . . . . . . . . . . . . . . Gear, Idler
21 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13164. . . . . . . . . . . . . . . . . . Gear, Drive
23 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13887. . . . . . . . . . . . . . . . . . Plate, Motor Mounting
24 . . . . . . . . . . . 1 . . . . . . . . . . . . . 18743. . . . . . . . . . . . . . . . . . Motor, 120V, 60 Hz 1/30 RPM, 5600
19659-1 . . . . . . . . . . . . . . . . Motor, 24V, 60 Hz 1/30 RPM
25 . . . . . . . . . . . 2 . . . . . . . . . . . . . 13278. . . . . . . . . . . . . . . . . . Screw, Phil Hd Mach, 6-32 x 1/8 Steel Zinc
26 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13830. . . . . . . . . . . . . . . . . . Pinion, Program Wheel Drive
27 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13831. . . . . . . . . . . . . . . . . . Clutch, Drive Pinion
28 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14276. . . . . . . . . . . . . . . . . . Spring, Meter Clutch
29 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14253. . . . . . . . . . . . . . . . . . Retainer, Clutch Spring
30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
31 . . . . . . . . . . . 3 . . . . . . . . . . . . . 11384. . . . . . . . . . . . . . . . . . Screw, Phil, 6-32 x 1/4 Zinc Rolling Screw
32 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13881. . . . . . . . . . . . . . . . . . Bracket, Hinge Timer
33 . . . . . . . . . . . 3 . . . . . . . . . . . . . 14087. . . . . . . . . . . . . . . . . . Insulator
34 . . . . . . . . . . . 1 . . . . . . . . . . . . . 10896. . . . . . . . . . . . . . . . . . Switch, Micro
35 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15320. . . . . . . . . . . . . . . . . . Switch, Micro, Timer
36 . . . . . . . . . . . 2 . . . . . . . . . . . . . 11413. . . . . . . . . . . . . . . . . . Screw, Pan Hd Mach, 4-40 x 1 1/8 MS Steel Zinc
37 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14007. . . . . . . . . . . . . . . . . . Label, Time of Day
38 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14045. . . . . . . . . . . . . . . . . . Label, Instruction
39 . . . . . . . . . . . 1 . . . . . . . . . . . . . 13902. . . . . . . . . . . . . . . . . . Harness, 3200 - Not Shown
41 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15354-01 . . . . . . . . . . . . . . . Wire, Ground 4” - Not Shown
42 . . . . . . . . . . . 1 . . . . . . . . . . . . . 15465. . . . . . . . . . . . . . . . . . Label, Caution - Not Shown
43 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14198. . . . . . . . . . . . . . . . . . Label, Indicator - Not Shown
Page 13
MODEL 2900s
30
Environmental Power Head
(See opposite page for parts list)
22
21
20
17
19
23
24
25
26
28
29
27
32
33 34
35
31
36
37
1
16
14
18
13
15
12
11
40
42
2
10
9
8
38
39
7
6
5
15
4
3
61501-29002
Page 14
MODEL 2900s
Environmental Power Head
Item No. Quantity Part No. Description
1 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .18697-15 . . . . . . . . . . . . . . . . . . . . . Backplate, Hinged
2 . . . . . . . . . . . . . . . .- . . . . . . . . . . . . . . . . .3200 Clock Timer Assy . . . . . . . . . . 3200 Clock Timer Assy
1 . . . . . . . . . . . . . . . . .3200 Meter Timer Assy . . . . . . . . . . 3200 Meter Timer Assy
3 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .40384 . . . . . . . . . . . . . . . . . . . . . . . . Motor, Drive, 115V, 60 Hz, SP, Fam 1
4 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .10774 . . . . . . . . . . . . . . . . . . . . . . . . Bracket, Motor Mounting
5 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .60160-10 . . . . . . . . . . . . . . . . . . . . . Drive Cam Assy, STF, Black
6 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .17904 . . . . . . . . . . . . . . . . . . . . . . . . Bushing, Heyco 1/2, Heyco #2073
7 . . . . . . . . . . . . . . . .5 . . . . . . . . . . . . . . . . .10872 . . . . . . . . . . . . . . . . . . . . . . . . Screw, Hex Wsh, 8-32 X 17/64 18-8 S.S.
8 . . . . . . . . . . . . . . . .3 . . . . . . . . . . . . . . . . .10302 . . . . . . . . . . . . . . . . . . . . . . . . Insulator, Limit Switch
9 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .10218 . . . . . . . . . . . . . . . . . . . . . . . . Switch, Micro
10 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .14923 . . . . . . . . . . . . . . . . . . . . . . . . Screw, Pan Hd Mach, 4-40 X 1 MS Steel Zinc
11. . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .11826-02 . . . . . . . . . . . . . . . . . . . . . Bracket, Motor, Aux Switch Brine Valve Side
12 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .10896 . . . . . . . . . . . . . . . . . . . . . . . . Switch, Micro
13 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .11805 . . . . . . . . . . . . . . . . . . . . . . . . Screw, Rd Hd, 4-40 X 5/8 Type 1 Steel Zinc
14 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .12472 . . . . . . . . . . . . . . . . . . . . . . . . Cam Assy, Tri-Stack, After RR
15 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .10338 . . . . . . . . . . . . . . . . . . . . . . . . Pin, Roll 3/32
16 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .10269 . . . . . . . . . . . . . . . . . . . . . . . . Nut, Jam, 3/4-16
17 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .10712 . . . . . . . . . . . . . . . . . . . . . . . . Fitting, Brine Valve
18 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .14822 . . . . . . . . . . . . . . . . . . . . . . . . Harness, 2900
19 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .19691 . . . . . . . . . . . . . . . . . . . . . . . . Plug, .750 Dia Recessed, Black
20 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .15806 . . . . . . . . . . . . . . . . . . . . . . . . Plug, Hole, Heyco #2693
21 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .19801 . . . . . . . . . . . . . . . . . . . . . . . . Plug, .190 Dia, White Heyco 0307
22 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .18693 . . . . . . . . . . . . . . . . . . . . . . . . Conduit, Interdrive
23 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .18691-01 . . . . . . . . . . . . . . . . . . . . . Fitting, Conduit
24 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .18692 . . . . . . . . . . . . . . . . . . . . . . . . Washer, 3/8”, Sealing
25 . . . . . . . . . . . . . . . .7 . . . . . . . . . . . . . . . . .19800 . . . . . . . . . . . . . . . . . . . . . . . . Plug, .140 Dia, White Heyco 0304
26 . . . . . . . . . . . . . . . .4 . . . . . . . . . . . . . . . . .10300 . . . . . . . . . . . . . . . . . . . . . . . . Screw, Slot Hex Wsh, 8-18 X 3/8 Type “B” RC 44-47
27 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .18691-02 . . . . . . . . . . . . . . . . . . . . . Nut, Conduit Fitting,1/2”
28 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .40038-03 . . . . . . . . . . . . . . . . . . . . . Label, Voltage, 120V, 3200ET
29 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .17421 . . . . . . . . . . . . . . . . . . . . . . . . Plug, 1.20 Hole Heyco #2733
30 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .60219-02 . . . . . . . . . . . . . . . . . . . . . Cover Assy, Environmental,Black W/Clear Window
31 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .19772 . . . . . . . . . . . . . . . . . . . . . . . . Bracket, Terminal Block
32 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .40174 . . . . . . . . . . . . . . . . . . . . . . . . Terminal Block, Green/Yellow commercial, 809-260/141
33 . . . . . . . . . . . . . . . .6 . . . . . . . . . . . . . . . . .41084 . . . . . . . . . . . . . . . . . . . . . . . . Terminal Block, Segment, Gray
34 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .41085 . . . . . . . . . . . . . . . . . . . . . . . . Endplate, Terminal Block, Gray
35 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .15250 . . . . . . . . . . . . . . . . . . . . . . . . Label, Terminal Strip
36 . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . .13296 . . . . . . . . . . . . . . . . . . . . . . . . Screw, Hex Wsh, 6-20 6-20 x 1/2 Type 25 Steel Zinc
37 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .40400 . . . . . . . . . . . . . . . . . . . . . . . . Harness, Drive, Designer/Environmental
38 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .40370 . . . . . . . . . . . . . . . . . . . . . . . . Label, Seriel Number, with Bar Code
39 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .40175-01 . . . . . . . . . . . . . . . . . . . . . Wire, Ground, Commercial Valves
40 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .13547 . . . . . . . . . . . . . . . . . . . . . . . . Strain Relief, Flat Cord Heyco #30-1
41 . . . . . . . . . . . . . . . .- . . . . . . . . . . . . . . . . .17967 (Not Shown) . . . . . . . . . . . . . Fitting Assy, Liquid-Tight, Black
42 . . . . . . . . . . . . . . . .1 . . . . . . . . . . . . . . . . .11545 . . . . . . . . . . . . . . . . . . . . . . . . Powercord, 4’ European, Black
40385 . . . . . . . . . . . . . . . . . . . . . . . . Motor, Drive, 24V, 50/60 Hz, SP Fam 1
40386 . . . . . . . . . . . . . . . . . . . . . . . . Motor, Drive, 220V, 50/60 Hz, Sp Fam 1
60160-30 . . . . . . . . . . . . . . . . . . . . . Drive Cam Assy, Upflow
60160-31 . . . . . . . . . . . . . . . . . . . . . Drive Cam Assy, Upflow, Variable
12777 . . . . . . . . . . . . . . . . . . . . . . . . Cam, Shut-Off Valve
15770 . . . . . . . . . . . . . . . . . . . . . . . . Cam Assy, Special Tri-Stack, After Brine Fill
15805 . . . . . . . . . . . . . . . . . . . . . . . . Cam, SVO
19887 . . . . . . . . . . . . . . . . . . . . . . . . Cam, Brine, 2750 U/F, Std
19749 . . . . . . . . . . . . . . . . . . . . . . . . Cam, Brine, 2750, U/F, Variable
X 7/8
13547-01 . . . . . . . . . . . . . . . . . . . . . Strain Relief, Euro Round Cord
13547-02 . . . . . . . . . . . . . . . . . . . . . Strain Relief, U.S. Round
14924 . . . . . . . . . . . . . . . . . . . . . . . . Strain Relief, Heyco #1247
19303 . . . . . . . . . . . . . . . . . . . . . . . . Powercord, 8’, Australian
19885 . . . . . . . . . . . . . . . . . . . . . . . . Powercord, Japanese, 110V/120V
40084-12 . . . . . . . . . . . . . . . . . . . . . Powercord, 12’ US, Round, 120V, Sys 5, 6, 7 & 2900/3150/3900
40085-12 . . . . . . . . . . . . . . . . . . . . . Powercord, 12’ US, Round, 240V
Parts List
*Part Numbers Printed in Bold and Italic are for Upflow Only*
Page 15
MODEL 2900s
Lower Environmental Power Head
(See opposite page for parts list)
19
3
5
4
1
7
13
16
18
14
17
15
12
6
8
2
10
20
9
11
22
61501-29003
Page 16
MODEL 2900s
Lower Environmental Power Head
Item No. Quantity Part No. Description
1. . . . . . . . . . . . 1 . . . . . . . . . . . . . 18709 . . . . . . . . . . . . . . Backplate, Lower
2. . . . . . . . . . . . 2 . . . . . . . . . . . . . 11224 . . . . . . . . . . . . . . Screw, Hex Hd, 5/16 - 18 x 5/8
3. . . . . . . . . . . . 2 . . . . . . . . . . . . . 16346 . . . . . . . . . . . . . . Nut, Hex, Jam, 5/16-18, 18-8 S.S.
4. . . . . . . . . . . . 1 . . . . . . . . . . . . . 18692 . . . . . . . . . . . . . . Washer, 3/8, Sealing
5. . . . . . . . . . . . 1 . . . . . . . . . . . . . 18691-01 . . . . . . . . . . . Fitting, Conduit
6. . . . . . . . . . . . 1 . . . . . . . . . . . . . 18691-02 . . . . . . . . . . . Nut, Conduit Fitting,1/2”
7. . . . . . . . . . . . 1 . . . . . . . . . . . . . 40387 . . . . . . . . . . . . . . Motor, Drive, 115v, 60 Hz, SP, Fam 2
7. . . . . . . . . . . . 1 . . . . . . . . . . . . . 40388 . . . . . . . . . . . . . . Motor, Drive, 24V, 50/60 Hz, SP, Fam 2
7. . . . . . . . . . . . 1 . . . . . . . . . . . . . 40389 . . . . . . . . . . . . . . Motor, Drive, 220V, 50/60 Hz, SP, Fam 2
8. . . . . . . . . . . . 1 . . . . . . . . . . . . . 14769 . . . . . . . . . . . . . . Bracket, Motor, 2900
9. . . . . . . . . . . . 1 . . . . . . . . . . . . . 40405 . . . . . . . . . . . . . . Harness, Lower Drive, Sys4, Env
10 . . . . . . . . . . . 1 . . . . . . . . . . . . . 10302. . . . . . . . . . . . . . Insulator, Limit Switch
11. . . . . . . . . . . . 1 . . . . . . . . . . . . . 10218. . . . . . . . . . . . . . Switch, Micro
12 . . . . . . . . . . . 2 . . . . . . . . . . . . . 19849. . . . . . . . . . . . . . Screw, Pan Hd, 4-40 X 5/8
13 . . . . . . . . . . . 1 . . . . . . . . . . . . . 18746. . . . . . . . . . . . . . Bearing, Connecting Rod
14 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14775. . . . . . . . . . . . . . Cam, Drive, 2900
15 . . . . . . . . . . . 1 . . . . . . . . . . . . . 41022. . . . . . . . . . . . . . Pin, Roll, 2900 Lower
16 . . . . . . . . . . . 1 . . . . . . . . . . . . . 14759. . . . . . . . . . . . . . Link, Piston Rod
17 . . . . . . . . . . . 1 . . . . . . . . . . . . . 10250. . . . . . . . . . . . . . Ring, Retaining
18 . . . . . . . . . . . 1 . . . . . . . . . . . . . 18725. . . . . . . . . . . . . . Indicator, Service/Standby
19 . . . . . . . . . . . 1 . . . . . . . . . . . . . 18726. . . . . . . . . . . . . . Spacer, Indicator
20 . . . . . . . . . . . 6 . . . . . . . . . . . . . 10872. . . . . . . . . . . . . . Screw, Hex Wsh,8-32 X 17/64 18-8 S.S.
21 . . . . . . . . . . . 6 . . . . . . . . . . . . . 14044 (Not Shown) . . . Tie, Cable, Heyco, Vnt#4-18
22 . . . . . . . . . . . 1 . . . . . . . . . . . . . 60217-02 . . . . . . . . . . . Cover Assy, 2900, Lower, Black, Environmental
Parts List
Page 17
MODEL 2900s
Designer Power Head
(See opposite page for parts list)
23
20
24
17
22
30
29
28
27
21
26
25
1
35
31
32
2
11
19
18
13
Page 18
14
15
12
10
9
8
7
6
5
15
4
16
3
61501-29001