For Water Heater and Hot Water Storage Tank Applications
ES-10L/100XL
Job Name
––––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––––––––
Engineer
––––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
–––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
Representative
–––––––––––––––––––––––––––––––––––––––––
IMPORTANT: INQUIRE WITH GOVERNING AUTHORITIES
FOR LOCAL INSTALLATION REQUIREMENTS
10L
Series 1L, 1XL, 10L and 100XL
Temperature and Pressure Relief Valves
A.S.M.E Rated*, CSA Listed. Self-closing T&P Relief Valves for Water Heaters up to 105,000 BTU/Hr.
The combined 2 in 1 T&P relief valve provides the least expen­sive and proven means for protection against both excessive temperature and pressure emergency conditions.
Provides fully automatic temperature and pressure relief protec­tion for hot water storage tanks and heaters up to 105,000 BTU/HR. Series 10L furnished with test lever and short ther­mostat for installation directly in tank tapping. Series 100XL furnished with test lever and extension thermostat for installa­tion in the hot water outlet line or directly in the tank tapping. Temperature sensing element must be immersed in the water within the top 6" (152mm) of the tank. Male inlet and female outlet. Temperature relief 210°F (99°C). Standard settings 75, 100, 125, 150psi (5.3, 7.0, 8.8, 10.6 bar).
Features
• Series 1L, 1XL Size 1⁄2" (15mm) 10L, 100XL Size
3
4" (20mm)
• A.S.M.E. Rated*, CSA Listed
• Features a unique thermostat with special thermo-bonded coating
• An all bronze body
• Stainless steel spring
• Thermostat is accurate and proven. Exclusively designed and manufactured by Watts
Options
• For tanks and heaters with extra thick insulation, send for literature ES-SL100XL/L100XL/LL100XL/LLL100XL
• Series 100XL-8 with 8" (200mm) extension thermostat
• SOLAR - Series 100XL or 1XL; specify Model Z9 for stainless steel lever and pin for outside solar applications. Model Z11 for 180°F (82°C) thermostat
• Series 1L, 1XL Size
1
2" (15mm): For both temperature and pressure relief protection. Series 1L has short thermostat and test lever. Series 1XL has extension thermostat with thermo­bonded coating. Also available with 8" (200mm) extension thermostat
Specifications
T&P valves
Each water heater and hot water storage tank shall be equipped with a CSA and A.S.M.E. Rated* automatic tempera­ture and pressure relief valve to protect the heater from exces­sive pressure and temperature. The device shall be ANSI Z21.22 certified. The BTU discharge capacity of the device shall be in excess of the BTU input rating of the heater. Watts Regulator Company No. 1L, 1XL, 10L or 100XL.
WARNING: Following installation, The valve lever MUST be operated AT LEAST ONCE A YEAR to ensure that the water-ways are clear. Certain naturally occurring mineral
deposits may adhere to the valve, rendering it inoperative. When manually operating the lever, water will discharge and precautions must be taken to avoid contact with hot water and to avoid water damage. BEFORE operating lever, check to see that a discharge line is connected to this valve directing the flow of hot water from the valve to a proper place of dis­posal otherwise personal injury may result. If no water flows, valve is inoperative. TURN OFF THE WATER HEATER AND
CALL A PLUMBER IMMEDIATELY.
This device is designed for emergency safety relief and shall not be used as an operating control.
100XL
* Series 1L and 1XL Valves are not A.S.M.E. Listed or Rated.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
MODEL SIZE DIMENSIONS CSA
Ordering (DN) A B D T Weight Temp. Steam
Code* in. mm in. mm in. mm in. mm in. mm oz. gm. Rating BTU/hr.
1L2 M7 00022681⁄2 15 13⁄4 43 31⁄2 89
7
8 22 2 50 10 284 15,000
1XL-4 M7 0004494
1
2 15 13⁄4 43 31⁄2 89
7
8 22 4 100 12 340 15,000
1XL-8 M7 00044971⁄2 15 13⁄4 43 31⁄2 89
7
8 22 8 203 16 454 15,000
10L-2 M7 0064014
3
4 20 13⁄4 43 31⁄2 89 11⁄8 29 2 50 10 284 80,000 100XL-4 M7 00661003⁄4 20 13⁄4 43 31⁄2 89 11⁄8 29 4 100 12 340 105,000 100XL-8 M7 0066110
3
4 20 13⁄4 43 31⁄2 89 11⁄8 29 8 203 14 397 105,000
A = overall width of the valve. B = overall height of the valve, with lever closed, not including thermostat element length. D = length of shank , from shoulder under outlet orifice overhang to inlet orifice edge. T = length of thermostat element, measured from inlet orifice edge to end of thermostat. * 150psi set pressure
Dimensions/Weights
Series 1L, 1XL, 10L and 100XL
Direct Side Tapping
For External Flue Heaters
Use extra length extension thermo­stat to extend into water storage tank.
For Internal Flue Heaters
Use short or standard length ther­mostat. Vertical discharge line must be installed with its direction down­ward.
T
B
A
D
WARNING: REINSPECTION OF T&P RELIEF VALVE: Temperature and Pressure Relief Valves should be reinspected AT LEAST ONCE EVERY THREE YEARS by a licensed plumbing contractor or authorized inspection agency, to insure that the product has not been affected by corrosive water conditions
and to insure that the valve and discharge line have not been altered or tampered with illegally. Certain naturally occurring conditions may corrode the valve or its components over time, rendering the valve inoperative. Such conditions are not detectable unless the valve and its components are physically removed and inspected. Do not attempt to conduct this inspection on your own. Contact your plumbing contractor for a reinspection to assure continuing safety. FAILURE TO REINSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD-UP WHICH CAN RESULT
IN SERIOUS INJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE.
IMPORTANT: A relief valve functions in an emergency by discharging water. Therefore, it is essential that a discharge line be piped from the valve in order
to carry the overflow to a safe place of disposal. The discharge line must be the same size as the valve outlet and must pitch downward from the valve and terminate at least 6"(152mm) above the floor drain where any discharge will be clearly visible. For 100DT discharge line consult your Watts agent.
Direct Top Tapping
For Heaters
Use standard or extra length extension thermostat.
Alternate
Only when the tappings are not provided
Use standard or extra length extension thermostat.
ES-10L/100XL 0828 © Watts, 2008
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
Water Safety & Flow Control Products