P OW E R S E R I E S C O N T R O L L E R S
M i c ro p ro c e s s o r- B a s e d
SCR Power Contro l l e r
Designed fo r
Application Flex i b i l i t y
Watlow has manufactured solid state power controllers for
over thirty years. Watlow’s POWER SERIES represents the
latest in SCR power controller technology.This microprocessor-based product offers features and application flexibility
unmatched by any other SCR power controller on the market
today.
Capabilities of Watlow’s POWER SERIES controllers include
single-phase and three-phase models from 65 to 250 amps.
Field configurable phase angle or zero cross firing improves
application flexibility on site where you need it.The 50/60Hz
independent operation allows utilization almost everywhere
in the world without special calibration considerations. Serial
communication utilizing Modbus™protocol provides remote
control setup and monitoring of load status from a nearby
computer station or control room.
On-board semiconductor fusing improves reliability by
protecting the SCRs from heater short circuits. Plus,
on-board heater bakeout and control diagnostics can help
eliminate initial start up problems. All these benefits are in a
touch-safe package that can be quickly and easily mounted
in your control cabinet.
Watlow’s POWER SERIES controllers are UL®and C-UL
recognized, so users can be assured that the controllers
meet world safety and operational standards.
®
Features and Benefits
Microprocessor-based technology
• Extremely versatile and field configurable
Snap-fit on a pre-mounted plate
• Simplifies installation
Models 65 through 250 amp ratings
• Handles a wide range of loads
Adjustable soft start
• Provides application flexibility
Heater and control diagnostics capability
• Monitors actual heater and controller performance
Electrically touch-safe package
• Enhances safety for installer and users
Serial communications with Modbus™RTU protocol
• Provides computer control and/or monitoring
Multizone capability
• Increases application flexibility and reduces panel space
UL®and C-UL®are registered trademarks of the Underwriter’s Laboratories, Inc.
Modbus™ is a trademark of Schneider Automation Inc.
1241 Bundy Boulevard
Winona, Minnesota 55987-5580 USA
Phone: 507-454-5300
Fax: 507-452-4507
Internet: www.watlow.com
e-mail: info@watlow.com
© 2003 Watlow Electric Manufacturing Company Printed in the USA on Recycled Paper, 15% Postconsumer Waste
WIN-PS-0403

Specifications
Power Bases
• Single phase, (2 SCRs)
• 3 phase, 2 leg control, (4 SCRs)
Resistive load only, zero cross firing only
• 3 phase, 3 leg control, (6 SCRs)
• 3 phase, 3 leg control, (6 SCRs) for 4-wire wye loads
• Multizone, two and three single-phase zones
Output Control Options
• Zero cross contactor, VÎ(dc) input
• Zero cross control, fixed time base
• Time base one or four seconds with digital programmer
• Zero cross control, variable time base
• Phase angle control and phase angle control with current limit
(not for 3-phase, 2-leg models)
• Soft start factory default four seconds upon power-up, and
adjustable from 0.0 to 120 seconds
• Soft start upon input signal change, output rate of change
adjustable to limit max rate of change from 0.1 to 100 percent
per 0.1 second. Factory default 10 percent
• Current transformer included when required
• Line voltage compensated (variable time base and phase angle
controllers only)
• Standby or non-operational mode
Output Voltage and Current Rating
• 24 to 120VÅ(ac) (+10 percent, -15 percent)
• 200 to 480VÅ(ac) (+10 percent, -15 percent)
• 200 to 600VÅ (ac) (+10 percent, -15 percent)
• 65 through 250 amps per pole, model dependent; see Output
Amperage Chart and Rating Curves
• Minimum load 1 amp rms ac
• Maximum leakage current 5mA
Alarms
• Single alarm relay
• Latching or non-latching
• Separate high and low values
• Alarm silencing (inhibit) on power up for alarm
• Alarm indication LEDs, shorted SCR, open heater, fuse
• Electromechanical relay, form C contact, software
configurable
• Minimum load current 10mA @ 5VÎ(dc)
• Rated resistive loads: 3 amps @ 250VÅ(ac) or 30VÎ(dc)
max., inductive load rating 1.5 amps with a power factor
≥ 0.4 without contact suppression
Heater Bakeout
• For single-phase (phase to neutral) and 3-phase 6 SCR
models only (not for 3-phase, 2-leg models)
• Soft start with over current trip, runs until programmed bakeout
time expires, then goes burst or phase angle firing. Factory
default of 24 hours
• Adjustable 0 - 9999 minutes with over current trip
• Internal current transformer included
Command Signal Input
Analog
• Field selectable linear voltage and current of low and high
points within 0-20mA and 0-10VÎ(dc)
• Manual control input through front panel
• Factory default 4-20mA input
• Voltage input impedance 11kW nominal
• Current input impedance 100W nominal
Digital
• On-board digital programmer/display and optional serial
communications
Retransmit
• Field selectable and scalable within 0-20mA,
800W maximum or 0-10VÎ(dc), load, 1KW minimum load.
The default is 4-20mA
• Resolution:
mA ranges = ±5µA
VÎ(dc) = ranges 2.5mV nominal
• Calibration accuracy:
mA ranges = ±20µA
VÎ(dc) ranges = 10mV nominal
• Temperature stability: 100ppm°C
Digital Programmer/Display and Communications
Capabilities
• Programming functions
• Adjust input and output control type, alarms and soft start,
heater bakeout and current limit prompts
• Monitoring functions
• Display input and output values along with actual
output current
• Data retention of digital programmer/display upon power failure
via nonvolatile memory
Serial Communications
• RS-232 for single drop control
• EIA-485 for single or multidrop control
• 32 units maximum can be connected.With additional
485 repeater hardware, up to 247 units may be connected
• Isolated
• Modbus™RTU protocol
• 1200, 2400, 4800, 9600, 19200 baud rates
Controller Power Supply
• Universal line voltage input range 100 to 240VÅ(ac)
(+10 percent, -15 percent) at 55VA max
• 50/60Hz ± 5 percent line frequency independent
• Controller line voltage for electronic power supply can be run
on separate line voltage
Natural Convection and Fan Cooled Models
• Cabinet venting may be required
• See Amperage chart on the back page for all models.
Power Dissipation (Watts)
• Approximately 1.25 watts/amp per controlled leg
Isolation
• Command signal to load and line/load to ground
2200VÅ(ac) minimum
• On-board semiconductor fuses provide SCR protection
Mounting
• Mounts on a removable subplate
• Heat sink fins must be mounted in vertical orientation
High Current Terminals
• Touch safe
• 10 mm (3⁄8in.) Allen head compression terminals will accept
#6 AWG to 350 MCM wire. Allen wrench adapter (included) for
10 mm (3⁄8in.) socket, 6 point only
• Torque to 180 in.-lbs (20.3 Nm)
• Wire strip to 30 mm (11⁄8 in.)
Controller Terminals
• Touch safe
• 2.5 mm (1⁄8 in.) blade screwdriver, accepts 12-22 AWG or
2 No. 22-18 AWG wires
• Torque to 8 in.-lbs (0.9 Nm)
• Wire strip to 6 mm (0.24 in.)
Operating Environment
• 50°C (122°F) base rating
• 0 to 60°C (32 to 140°F) fan cooled
• 0 to 65°C (32 to 149°F) natural convection cooled
• 0 to 90 percent RH, non-condensing
• Meets EN50178, Pollution degree three
Storage Temperature
• -40 to 85°C (-40 to 185°F)
Shipping Weight
• 10.3 kg (23 lbs)
Agency Approvals
• UL®508 listed, File #E73741, Vol. three, Sec.two
• C-UL®listed to C22.2 NO. 14
• VDE EN 50178 License 115054
• CE 89/336/EEC (EN61326), Class A with filter,
CE 73/23/EEC (EN50178)
Modbus™ is a trademark of Schneider Automation, Inc.

Ordering Information
POWER SERIES P C _ _ - _ _ _ _ - _ _ _ _
Microprocessor-based,
solid state power controller
Package Style
C = 65 to 250 amps
Phase
1 = 1 phase
2 = 3-phase/2-leg control, (4 SCRs)
3 = 3-phase/3-leg control, (6 SCRs)
4 = 3-phase/4-wire, wye
connected load
8 = 2 single-phase zones
9 = 3 single-phase zones
Heater Diagnostics
0 = None
1 = Heater diagnostics (required for any
heater current monitoring or current
limiting).
Output Amperage Rating
(See amperage chart to the right)
Output Voltage Rating
A = 24 to 120V
B = 200 to 480V
C = 200 to 600V
Communications
0 = None
1 = EIA/TIA-232/485 communications,
opto-isolated (field selectable)
Feedback/Retransmit
0 = None
1 = Load current feedback (0-10V or 0-20mA scalable
retransmit output) (Must have heater
diagnostics selected)
Custom
00 = None
AA = No Watlow logo with agency approval marks
XX = Custom, consult factory for options
Your Authorized Watlow Distributor Is:
Single Phase Configuration
This configuration can be purchased with any or all the
features available on the POWER SERIES, based on
customer preference. It is intended for resistive heaters,
but can also be used on transformer connected loads in
the phase angle firing mode.
Three-Phase,Two Leg Configuration
This configuration is intended for zero cross firing only into
a stable resistive heater.Typically, a three-phase delta or
ungrounded wye connected heater is used and only two of
the three V~ line phases are switched.The third phase
is a direct connection through a bussbar on board the
POWER SERIES. Heater current monitoring and kVA options
are available via the heater diagnostics option.
Three-Phase,Three Leg Configuration
All POWER SERIES options are ava i l a ble with this
c o n fig u ra t i o n . It wo rks well with phase angle firing into a
t h r e e - p h a s e, three-wire wye or delta connected heater.In this
c o n fig u ration, the more common applications are tra n s fo rm e r
connected loads with heaters requiring a soft start and/or
current limiting.
The three-phase, four-wire configuration is intended for zero
cross firing into a three-phase grounded wye/star heater (This
is a separate hardware option, model number dependent.)
Single-Phase, Multizone Configuration
This configuration is available in two and three single-phase
zones and all the features of a single-phase unit are
available.(Note that there is only one alarm relay and all
zones in the controller must use the same control method.)
Heater Diagnostics
Heater diagnostics may include some or all of the
features that require heater current monitoring, depending
on the model selected. Heater current monitoring is only
available with heater diagnostics installed on the controller.
The features dependent on heater current monitoring are
heater bakeout, current limiting, heater kVA monitoring,
retransmit and heater monitoring alarms such as open heater,
heater out of tolerance, load balance and shorted SCR
detection/error.Heater diagnostics must also be installed
if you need phase angle control with current limit.
Amperage Chart—50˚C (122˚F)
Non-Fan Cooled
2 Zone and 3 Zone and
Single Phase 3 Phase, 2 Leg 3 Phase, 3 Leg
Code Amperage Code Amperage Code Amperage
N20 100A N20 80A N20 65A
N25 140A N25 105A N25 85A
N30 165A N30 120A N30 105A
Fan Cooled
Single Phase 3 Phase, 2 Leg 3 Phase, 3 Leg
Code Amperage Code Amperage Code Amperage
F20 125A F20 120A F20 90A
F25 200A F25 160A F25 140A
F30 250A F30 185A F30 155A
North American Sales Offices: Atlanta, (770)972-4948 • Austin, (512)249-1900 • Birmingham, (205)678-2358 • Charlotte, (704)573-8446 •
Chicago, (847)458-1500 • Cincinnati, (513)398-5500 • Cleveland, (330)467-1423 • Dallas, (972)620-6030 • Denver, (303)798-7778 •
Detroit, (248)651-0500 • Eastern Canada, (450)433-1309 • Houston, (281)440-3074 • Indianapolis, (317)575-8932 • Kansas City, (913)897-3973 •
Los Angeles, (714)935-2999 • Louisiana, (318)864-2864 • Maryland/Virginia, (215)345-8130 • Minneapolis/Manitoba, (952)892-9222 •
Nashville, (615)264-6148 • New England, (603)882-1330 • NewYork/New Jersey/Philadelphia, (215)345-8130 • New York,Upstate, (716)438-0454 •
Ontario, (905)979-3507 • Orlando, (407)351-0737 • Phoenix, (602)298-6960 • Pittsburgh, (412)322-5004 • Portland, (503)245-9037 •
Raleigh/Greensboro, (336)766-9659 • St.Louis, (314)878-4600 • Sacramento, (707)425-1155 • San Diego, (714)935-2999 •
San Francisco, (408)434-1894 • Seattle, (425)222-4090 • Tampa/St. Petersburg, (407)647-9052 • Tulsa, (918)496-2826 •
Western Canada, (604)444-4881 • Wisconsin, North (920)993-2161 • Wisconsin, South (262)723-5990
Asian Sales Offices: Australia, +61 (3) 9335-6449 • China, +86 (21) 6277-2138 • Japan, +81 (03) 5403-4688 • Korea, +82 (02) 575-9804 •
Malaysia, +60 (4) 641-5977 • Singapore, +65 777-9488 • Taiwan, +886 (0) 7-288-5168 European Sales Offices: France, +33 (01) 3073-2425 •
Germany, +49 (0) 7253-9400-0 • Italy, +39 (02) 458-8841 • Sweden, +46 31 7014959 • United Kingdom, +44 (0) 115-964-0777
Latin American Sales Office: Mexico, +52 (442) 217-6235