Watlow Electric 1100, 1120 User Manual

RAYMAX®1120—
Lightweight, Sturdy
Radiant Heater
Panel
The RAYMAX®1120 is a lightweight, yet sturdy and durable radiant heater panel.The emitter sheath is stainless steel with a black coating that makes it a highly efficient radiating surface. In addition, the heater's low mass allows rapid start-up and fast response to controls.
The patented RAYMAX heater features one-inch (25 mm) wide emitter strips that are individually replaceable for lower maintenance costs.Weighing only 5.5 lbs/ft
2
(26.8 kg/m2), the
heater is easy to mount.

Applications

• Thermoforming
• Textile drying
• Paint curing
• Powder coating fusing
• Shrink wrapping
• Circuit board soldering
FAX-1120-1100
12001 Lackland Road St. Louis, Missouri 63146 USA Phone: 314-878-4600 FAX: 314-878-6814 Internet: www.watlow.com e-mail: info@watlow.com
RAYMAX 1120
Features and Benefits
Replaceable emitters
• Reduce your costs
High temperature mica
• Electrically insulates nickel chromium resistance wire, permitting longer heater life
High emissivity coating on emitter strips
• Improves radiant heating efficiency
One-inch thick thermal insulation
• Backs the emitter strips to reduce backside losses
Uniform full surface heat source
• Provides better, more even heat
Special requirements easily met
• Custom sizes and ratings available
Next day shipment
• Available on stock sizes
Aluminized Steel Case
High Temperature Mica
Sinuated Element Wire
1" Wide Replaceable Stainless Steel
Emitter With High Emissivity Coating
1" (25 mm) Thermal Blanket Insulation
© 2001 Watlow Electric Manufacturing Company
RAYMAX 1120

How to Order

To order your stock RAYMAX heater, specify:
• RAYMAX 1120
• Quantity
• Watlow code number (from Watlow Heater's Catalog) If our stock units do not meet your application needs,
Watlow can manufacture RAYMAX heaters to your special requirements. For made-to-order heaters, specify the following:
• Heated width and length.Three-phase panels must have width divisible by three.
• Total wattage of each panel.
• Exact voltage and phase.A five percent variation in voltage at the oven will cause a 10 percent variation in power.
• Zoning. Indicate dimensions and wattage of each zone.
• Mounting legs or mounting studs, if desired. For studs, give number and location, or indicate standard location.
• Terminal location if non-standard.
• Terminal box or wire raceway, if required.
Supplying a drawing with an order or request for quotation can be very helpful in clarifying design information.
Availability Stock: Next day shipment.
Made-to-Order: Consult Watlow.
Applications and Technical Data
Face T emperature: 1100°F maximum (595°C) Wattage:Watt densities up to 20 W/in
2
(3 W/cm2)
Standard V oltage:120, 240, 480VÅ(ac), 1-phase. Balanced 3-phase available on unit widths divisible by three. Other voltages are available.
Terminals:Non-standard locations are also available. Please specify.
Standard Dimensions1⁄16 inch (0.0625 mm) Typical Peak Energy Wavelength: 3-3.5 microns

Specifications

1
9
/16
"
(39 mm)
Overall Width =
Heated Width
+
3
/8
"
(9.5 mm)
Overall Length =
Heated Length
+ 1
1
/4
"
(31.75 mm)
A B
3
/8
"
(9 mm)
3
/8
"
(9 mm)
7
/8
"
(22 mm)
1
1
/2
"
(38 mm)
1
3
/16
"
(30 mm)
1
1
/2
"
(38 mm)
Width: inches (mm) 1 (25.4) 36 (914.4) 1 (25.4) Length: inches (mm) 6 (152.4) 70 (1778) any Area: in2(cm2) 6 (38.7) 864 (5574.2) any
Note: Less than maximum length X width may exceed maximum area.
Heater Dimensions Min. Max. Increments
Loading...