Watlow Thermocouples Data sheet

W A T L O W
63
Thermocouples
Mineral Insulated
Watlow’s mineral insulated thermo­couples are fast-responding, durable, and capable of handling high temperatures.
These thermocouples are manu­factured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material. XACTPAK responds fast because the protective metal outer sheath allows the use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperforms bare wire thermocouples in most applications.
Performance Capabilities
• Easily handles temperatures up to 1200°C (2200°F)
• Meets or exceeds initial calibration tolerances per ASTM E 230
Features and Benefits
Special mineral insulation
Protects thermocouple from
moisture and thermal shock
• Permits operation in high temperature, high pressure environments
Diameters as small as 0.010 in. (0.25 mm)
Ideal when physical space or
extremely fast response are critical
Flexibility of the XACTPAK material
Allows you to form and bend the
thermocouple, without risk of cracking, to meet your design requirements
Outer sheath
Protects the wires from oxidation
and hostile environments
Wide range of sheath materials, diameters, and calibrations
Meet specific requirements In-house manufacturing of
XACTPAK material
Rigid quality control procedures
Assures high standards are met
Single source reliability Custom capabilities
Include options such as special
lead lengths, lead wires and terminations
Applications
• Heat treating
• Furnaces/kilns
• Turbines
• Bearing temperature
• Power stations
• Steam generators
• Diesel engines
• Nuclear reactors
• Atomic research
• Jet engines and test cells
• Rocket engines
• Semiconductor manufacturing
• Refineries/oil processing
• Catalytic reformers
• Food processing
Thermocouples
66
Rapid Ship sensors come with standard male thermocouple connector directly attached to sheath, Type J or K, ungrounded junction, 0.125, 0.188 or 0.250 inch diameter and six or 12 inch sheath length.
Rapid Ship Sensors
3. Sheath O.D. (inch)
D = 0.040 H = 0.188
E = 0.063 J = 0.250 G = 0.125
4. Connector Type
Standard Plugs and Jacks 218°C (425°F)
A = Standard plug
B = Standard jack C = Standard plug with mating connector
High Temperature Plugs and Jacks 540°C (1000°F) (0.250 inch maximum O.D.) L = High temperature plug M = High temperature jack N = High temperature plug with mating connector
5. Fittings, Weld Pads
If required, enter order code from pages 39-40. If none, enter “0’’.
6. Enter “0’’
7. Sheath Material
A = 304 SS Q = Alloy 600 (Type K)
F = 316 SS
C = PFA coated over SS (available on G, H, J diameters)
8-9. Sheath Length “L’’ (whole inches)
04, 06, 12, 18, 24
Available lengths: 01 to 99, over 99 consult factory Maximum length for PFA coating is 48 inches.
10. Sheath Length “L’’ (fractional inch)
0 = 0 2 = 1⁄4 4 = 1⁄2 6 = 3⁄4
1 = 1⁄8 3 = 3⁄8 5 = 5⁄8 7= 7⁄8
11. Junction
Grounded Ungrounded Exposed Single GUE Dual H W (isolated) D (isolated)
12. Calibration
EJKNT Standard limits E JKN T Special limits 2 3 4 8
13-14. Enter “00’’
15. Special Requirements
0 = None
X = Special requirements, consult factory
Thermocouples
Mineral Insulated
Standard Plug or Jack Termination
Style AC
L
AC 0 0
123456789101112131415
0
Custom Ordering InformationItems in Bolded Green Type are preferred
with shorter lead times.
Sheath Sheath Length
Sheath Diameter in. (mm)
Calibration Material in. (mm) 6 (152) 12 (305)
0.125 (3.2) ACGA00F060UJ000 ACGA00F120UJ000
J 316 SS 0.188 (4.8) ACHA00F060UJ000 ACHA00F120UJ000
0.250 (6.4) ACJA00F060UJ000 ACJA00F120UJ000
0.125 (3.2) ACGA00Q060UK000 ACGA00Q120UK000
K Alloy 600 0.188 (4.8) ACHA00Q060UK000 ACHA00Q120UK000
0.250 (6.4) ACJA00Q060UK000 ACJA00Q120UK000
Loading...