Watlow RTDs and Thermistors Data sheet

Page 1
W A T L O W
99
RTDs and Thermistors
RTDs and Thermistors
Resistance Temperature Sensing
Watlow’s platinum resistance elements are specially designed to ensure precise and repeatable temperature versus resistance characteristics. The sensors are made with controlled purity platinum, have high purity ceramic components and constructed in a unique strain­free manner.
Performance Capabilities
• Ceramic elements are extremely precise and stable within the wide temperature range of -200 to 650°C (-328 to1200°F).
Features and Benefits
Patented, strain-free construction
• Provides dependable, accurate readings
• Allows elements from different lots to be substituted without recalibration
High signal-to-noise output
• Increases accuracy of data transmission
• Permits greater distances between sensor and measuring equipment
Temperature coefficient (alpha) carefully controlled while insulation resistance values exceed DIN-IEC-751 standards
• Ensures sensor sensitivity
• Minimizes self heating
• Allows precise measurement
• Repeatable
Highly controlled manufacturing process
Ensures wide temperature range
• Stabilizes physical and chemical attributes
Metric diameters and fittings are available, please consult factory
Applications
• Air conditioning and refrigeration servicing
• Furnace servicing
• Stoves and grills
• Textile production
• Plastics processing
• Petrochemical processing
• Micro electronics
• Air, gas and liquid temperature measurement
• Exhaust gas temperature measurement
Page 2
RTDs and Thermistors
Speciality RTDs and Thermistors
Construction Styles
10 = 6 in. Adjustable Spring Style 11 = 12 in. Adjustable Spring Style
12 = Adjustable Armor Style
50 = Open Air
80 = Surface Mount55 = Open Air with Flange
25 = Cartridge with Flange
0.265 in. (6.7 mm)
O.D.
L
E
0.
3125 in.
(7.9 mm)
0.625 in.
(15.9 mm)
Stainless Steel Sheath
and Flange
Flange
0.648 in.
(16.5 mm)
0.324 in. (8.2 mm)
0.187 in. (4.7 mm)
0.373 in. (9.5 mm)
0.156 in.
(4 mm) Dia.
(3) Holes
L
E
0.625 in.
(15.9 mm)
Stainless Steel Sheath
and Flange
0.187 in. (4.7 mm)
L
E
Flange
0.648 in.
(16.5 mm)
0.324 in. (8.2 mm)
0.373 in. (9.5 mm)
0.156 in.
(4 mm) Dia.
(3) Holes
4.7 mm (0.187 in.)
0.875 in.
(22.2 mm)
0.101 in. (2.6 mm) Dia. (4) Holes
1.375 in.
(34.9 mm)
0.250 in. (6.3 mm)
0.343 in. (8.7 mm)
E
Aluminum Body
0.531 in.
(13.5 mm)
0.250 in. (6.3 mm)
See next page for Rapid Ship sensors and ordering instructions.
W A T L O W
107
RTDs and Thermistors
0.3125 in. (7.9 mm)
L
(Spring O.D. = 0.250 in. (6.4 mm)
E Spring Length
L
0.187 in. (4.7 mm)
E
Page 3
108
Construction 10 with Fiberglass and S10DDN4C048A S10DDN4C072A SS overbraid leads Construction 80 with Teflon®leads S80ADT2A048A S80ADT2A072A
RTDs and Thermistors
Speciality RTDs and Thermistors
Specifications: RTD
• Two- or three-wire
• Resistance: 100at 0°C
• Alpha curve: 0.00385Ω/Ω/°C
• Tolerance at 0°C: ±0.12% (±0.25°C)
• Range: -50 to 260°C (-58 to 500°F)
Specifications: Thermistor
• Metal oxide, sintered and encapsulated
• Negative temperature coefficient
• Non-linear temperature/resistance curve
• Resistance at 25°C (77°F) and ranges:
2-3. Construction
10 = 6 inch adjustable spring style
11 = 12 inch adjustable spring style 12 = Adjustable armor style 25 = Cartridge with flange 50 = Open air 55 = Open air with flange
80 = Surface mount
4. Diameter (inch)
D = 0.188
A = Not applicable: surface mount
5. Element Type
C = RTD 2-wire No. 3850 N = Thermistor No. 12
D = RTD 3-wire No. 3850 P = Thermistor No. 16
M = Thermistor No. 11
6-7. Lead Type
L4 = Fiberglass and SS armor M4= Fiberglass N4 = Fiberglass and SS overbraid
T2 = PFA or TFE
8. Sheath Length “L” (inches)
A = Not applicable C = 1.5 (required for VAT construction: No. 10, 11, 12)
D = 2.0 L = 5.5 T =9.0
E = 2.5 M = 6.0 U =9.5 F = 3.0 N = 6.5 W =10.0 G = 3.5 P = 7.0 Y =11.0
H = 4.0 Q = 7.5 Z =12.0
J = 4.5 R = 8.0 K = 5.0 S = 8.5
9-11. Lead Wire Length “E” (foot)
012 = 1 084 = 7
024 = 2 096 = 8
036 = 3 108 = 9
048 = 4 120 = 10
060 = 5 180 = 15 072 = 6
12. Terminations
A = 1.5 inch stripped split leads, no terminals
B = No. 8 spade terminals H = 0.25 inch female quick connect terminals
S
123456789101112
*Other thermistors available on request.
Consult factory. See Style TB thermistor on page 109.
#11 1000 -60 to 150°C (-76 to 302°F) #12 3000 -60 to 150°C (-76 to 302°F)
Epoxy Bead Tolerance
±1%+0.3°C (37°F)
#16 100,000-60 to 260°C (-76 to 500°F)
Glass Bead Tolerance
±15%+0.3°C (37°F)
*
Custom Ordering Information—Items in Bolded Green Type are preferred
with shorter lead times.
Part Number
4 Foot (102 mm) Leads 6 Foot (152 mm) Leads
Rapid Ship sensors come with 100DIN 0.00385 curve RTD sensor, 24 AWG stranded three­wire leads, temperature rating -50 to 260°C (-58 to 500°F), standard split end lead termination and no mounting fittings.
Rapid Ship Sensors
Loading...