Watlow RTD Data sheet

W A T L O W
99
RTDs and Thermistors
RTDs and Thermistors
Resistance Temperature Sensing
Watlow’s platinum resistance elements are specially designed to ensure precise and repeatable temperature versus resistance characteristics. The sensors are made with controlled purity platinum, have high purity ceramic components and constructed in a unique strain­free manner.
Performance Capabilities
• Ceramic elements are extremely precise and stable within the wide temperature range of -200 to 650°C (-328 to1200°F).
Features and Benefits
Patented, strain-free construction
• Provides dependable, accurate readings
• Allows elements from different lots to be substituted without recalibration
High signal-to-noise output
• Increases accuracy of data transmission
• Permits greater distances between sensor and measuring equipment
Temperature coefficient (alpha) carefully controlled while insulation resistance values exceed DIN-IEC-751 standards
• Ensures sensor sensitivity
• Minimizes self heating
• Allows precise measurement
• Repeatable
Highly controlled manufacturing process
Ensures wide temperature range
• Stabilizes physical and chemical attributes
Metric diameters and fittings are available, please consult factory
Applications
• Air conditioning and refrigeration servicing
• Furnace servicing
• Stoves and grills
• Textile production
• Plastics processing
• Petrochemical processing
• Micro electronics
• Air, gas and liquid temperature measurement
• Exhaust gas temperature measurement
W A T L O W
101
RTDs and Thermistors
RTD Style RC
Plug or Jack Termination
Features and Benefits
Durable rigid sheath
• 316 stainless steel -50 to 260°C (-58 to 500°F)
Durable connectors with copper pins
• 200°C (400°F) temperature rating
• Provide simple connection to extension leads
Brazed adapter
• Provides superior connector attachment
High accuracy
• Dependable readings
3. Sheath O.D. (inch)
G = 0.125
H = 0.188
J = 0.250
4. Cold End Termination
Standard plugs and jacks 200°C (400°F) A = Standard plug
C = Standard plug with mating connector
5. Fittings
If required, enter order code from pages 39 to 40.
If none, enter “0”.
6. Enter “0”
7. Sheath Construction
A = 316SS
8-9. Sheath Length “L” (inch)
02, 04 and 06
Whole inches: 02 to 36
10. Sheath Length “L” (fractional inch)
0 = No fraction, whole inches
1=1⁄8 3=3⁄8 5=5⁄8 7=7⁄8 2=1⁄4 4=1⁄2 6=3⁄4
11. Element
2-wire 3-wire
100Single A B
12. Temperature Coefficient
DIN 0.00385
A = Class A B = Class B
13-14. Enter “00”
15. Special Requirements
0 = None X = Special requirements, consult factory
RC 000
123456789101112131415
L
RTDs and Thermistors
Custom Ordering InformationItems in Bolded Green Type are preferred
with shorter lead times.
A