Watlow QPAC Specifications

Page 1
QPAC
TOTAL
3 Year Warranty
CUSTOMER
SATISFACTION
Modular SCR Power Controller for Custom Tailoring to the Application
The QPAC SERIES from Watlow® is a modular Silicon Controlled Rectifier (SCR) power controller with plug-in features for flexibility. Bases are rated from 150 to 1000 amperes in one-phase, three-phase, two leg and three-phase, three leg.
A variety of transformers from 120 to 575VAC along with 50/60Hz operation enable the QPAC to operate in applications anywhere. Plug-in control cards set the QPAC’s SCR firing modes; solid state contactor, burst firing (zero cross) or phase-angle models are available with a wide variety of options. This power controller includes 200KA short circuit current rating (SCCR) and high speed fuses to minimize damage in the event of a short circuit.
Typical Applications
Furnace and ovens
Petrochemical
Heat treating
Duct heating
Environmental chambers
Kilns

Features and Benefits

200KA short circuit current rating (SCCR)
Minimizes damage in the event of a short circuit
Modular power controller
Unit base can be fitted with a variety of plug-in
transformers and control cards
Available in 150 to 1000 ampere ratings
Handles large or small loads
Available in solid state contactor, burst firing (zero cross) or phase-angle fired mode
Meets most application requirements
Rugged design for 122°F (50°C) ambient operation
Full rating of the power controller can be used in
industrial applications
Semiconductor fuses and snubber protection included
Protects the SCR from voltage or current surges or spikes
Open heater or shorted SCR detector option
Diagnostic capabilities
UL® 508 listed and C-UL® up to 1000 amperes
For applications requiring agency approvals
© 2013 Watlow Electric Manufacturing Company all rights reserved.
®
WIN-QPAC-0613
Page 2

Specifications

Operation Modular controller base with plug-in card and
transformer
• Plug-in control cards Solid state contactor, dc input Burst fire control, fixed or variable time base Phase-angle fire control Phase-angle control with soft start and current limiting
• Plug-in transformers (50/60Hz)
• 120, 208, 240, 380, 415, 480, 575VAC operation
Power bases
• 1-phase (Q01), 1 pair of SCRs
• 3-phase (Q32), 2 leg control, 2 pair SCRs Resistive load only, burst firing only
• 3-phase (Q33), 3 pair hybrid SCRs/diodes Recommended for phase-angle only with balanced load
Agency Approvals
• UL® 508 and C-UL® listed, 150 to 300A all configurations, File #E73741
• UL® 508 and C-UL® listed, 400 to 1,000A on Q01 and Q32, up to 480VAC
Control Card Inputs (CD) Solid state contactor, dc input
• On, 4-32VDC; off, 0.5VDC
• Built-in noise reduction network
(BF) Burst firing control fixed time base
• Process input factory set @ 4-20mA DC
• Input impedance 250Ω (clip resistor for 5kΩ impedance voltage input), or manual control input
• Time base 4 seconds (clip resistor for 1 sec)
(BV) Burst firing control, variable time base
• Process input factory set @ 4-20mA DC
• Input impedance 250Ω (clip resistor for 5kΩ impedance voltage input), or manual control input. Requires an accessory bias and gain card to calibrate for 0-5VDC input
(AF) Phase-angle control
• Process input factory set @ 4-20mA DC
• Input impedance 250Ω (clip resistor for 5kΩ impedance voltage input), or manual control input
• Soft start approximately 6 seconds upon power-up, 1 second upon set point change
(AL) Phase-angle control with current limit
• Process input factory set @ 4-20mA DC
• Input impedance 250Ω (clip resistor for 5kΩ impedance voltage input), or manual control input
• Soft start approximately 10 seconds upon power-up, 1 to 2 seconds upon set point change
• Current transformer included
Open Heater/Shorted SCR Detector
• Zero cross/burst fire models only
• Triac output
• 24 to 240VAC, 300mA @ 77°F (25°C), 125mA @ 176°F (80°C)
• Energizes on alarm
• Holding current 200µA min.
• Latching current 5mA typical
Outputs
• 120 through 575VAC
• 1, 2 or 3 pole
• 150 to 1000A per pole
• SCCR, 200KA with original equipment specified semiconductor fusing
Line Voltage / Power
• 50/60Hz ac line frequency, Q32 and Q33 models are 50/60Hz calibration dependent
• Voltage: ±10%, 120, 208, 240, 277, 380, 415, 480, 575VAC
Line Voltage Compensation
• 10% ∆ in line, 2% ∆ in load in the 30 to 70% power region (AF, AL and BV)
Power Dissipation (Watts)
• 1.5 W/A per controlled leg
Isolation
• Command signal to load 1250VAC min.
Linearity
• 2%, 30 to 70% power region (All units except CD)
Off-State Leakage Current
• 20mA @ 480VAC
SCR Protection
• Semiconductor fuses provided dv/dt 200V/µsec min.
• MOV1 and RC snubber network standard
• (Q32) 3rd leg fuse kit may be used, but not required, with 3-phase, 2 leg models
Mounting
• Heat sink fins must be mounted in vertical orientation
Operating Environment
• 32 to 122°F (0 to 50°C)
• 0 to 90% RH, non-condensing
• 2,000 meters altitude
Storage Temperature
• -40 to 185°F (-40 to 85°C)
Options
• Manual Control Kit for process input cards (1kΩ potentiometer) #08-5362
• 240VAC and 120VAC cooling fans
1
MOV comes only on Q33 (3-phase, 3 leg).
QPAC Weight Chart
Phase
Amps
150 15 (6.8) 36 (16.3) 50 (22.7)
200 15 (6.8) 36 (16.3) 50 (22.7)
300 15 (6.8) 36 (16.3) 50 (22.7)
400-600 44 (20.0) 85 (38.5) 100 (45.4)
800-1000 49 (22.2) 120 (54.4) 135 (61.2)
1Ø/Q01
lb (kg)
3Ø, 2-leg/Q32 lb (kg)
3Ø, 3-wire/Q33 lb (kg)
Page 3

Case Styles

Depth
Width
Style C
Width
Style E
Height
Depth
Height

QPAC Dimensions

Q01
Height (H)
Style Amps
C 150 13 (330) 6.9 (175) 10.25 (260)
C 200 13 (330) 6.9 (175) 10.25 (260)
C 300 13 (330) 6.9 (175) 10.25 (260)
E 400-600 27 (685) 17 (430) 11.7 (300)
E 800-1K 27 (685) 17 (430) 13.3 (340)
Style Amps
C 150 13 (330) 13.7 (350) 10.25 (260)
C 200 13 (330) 13.7 (350) 10.25 (260)
C 300 13 (330) 13.7 (350) 10.25 (260)
E 400-600 27 (685) 21 (535) 11.7 (300)
E 800-1K 33 (840) 21 (535) 13.3 (340)
Style Amps
C 150 13 (330) 20.7 (525) 10.25 (260)
C 200 13 (330) 20.7 (525) 10.25 (260)
C 300 13 (330) 20.7 (525) 10.25 (260)
E 400-600 33 (840) 27 (685) 11.7 (300)
E 800-1K 33 (840) 27 (685) 13.3 (340)
in. (mm)
Q32
Height (H) in. (mm)
Q33
Height (H) in. (mm)
Width (W) in. (mm)
Width (W) in. (mm)
Width (W) in. (mm)
Depth (D) in. (mm)
Depth (D) in. (mm)
Depth (D) in. (mm)

Applications Sketch

In heat treating applications, the QPAC offers modular flexibility. Different heater elements require different control firing modes: i.e., tungsten elements need phase-angle firing, while Nichrome
Shipping the furnace to different countries could require different voltage sources (and thus transformers): i.e., U.S. 240 or 480 volt, Australia 415 volt; Europe 380 or 400 volt. By simply changing plug-in transformers, the OEM can ship anywhere in the world.
®
elements use burst (zero cross) firing.
Plug-in Transformer
Plug-in Control Card
Power Base
Page 4

Ordering Information

QPAC - Modular power controller; phase, burst or solid state contactor, fuse(s) and holder(s) included.
Part Number
Q
④ ⑤
Phase
- - -
Operating
& Output
Voltage
Cooling
Fan
Voltage
⑧ ⑨
Output
Control
(Amps)
Input
Control
Card
Open Heater/
Shorted SCR
Detector
② ③ Phase
01 =
1-phase
32 = 3-phase, 2-leg (Optional 3rd leg fuse kit extra)
33 = 3-phase, 3-leg
④ ⑤ Operating and Output Voltage
12 =
120VAC
20= 208VAC
24 = 240VAC
27= 277VAC
38= 380VAC
41 = 415VAC
48 = 480VAC
57 = 575VAC
Cooling Fan Voltage
1 =
120VAC; required on all 3-phase models
2 =
240VAC; required on all 3-phase models
Notes:
• Customer to supply wiring and hook-up.
• All cooling fans rated at 20 W each, must be wired by customer.
⑦ ⑧ ⑨ Output Control (Amps)
150 =
150A
200 = 200A
300 = 300A
400 = 400A
500 = 500A
600 = 600A
800 = 800A
01k = 1000A
⑩ ⑪ Input Control Card
CD = Solid state dc input (08-5286) contactor 4-32VDC
BF = Burst fired, fixed time base (08-5289) 4-20mA dc
BV = Burst fired, variable time base (08-5342) 4-20mA dc
AF = Phase-angle fired, not available on Q32 (08-5288) 4-20mA dc
Phase-angle fired w/current limit (08-5411) 4-20mA, not
AL =
available on Q32. AL option includes one current transformer. Add second CT for 3-phase, 3-leg
Open Heater/Shorted SCR Detector
0 =
None
1 = 1-phase operation
2 = 3-phase operation
Notes:
• The open heater/shorted SCR detector is for burst fire operation only.
• Includes one current transformer for 1-phase and two current transformers for 3-phase.

Wiring Example

Fuse
L1 L2
Fuse
Fuse
L3
Control Card
Command Signal
L1 T1 L2
Fan Fan Fan
T2 L3 T3
Q33-481-150-BFO
Transformer
Fan Must Be Wired to 120VAC

Accessories

Manual Control Kit 08-5362 150A : 5A Current Transformer 16-0008 200A : 5A Current Transformer 16-0045 300A : 5A Current Transformer 16-0073 400A : 5A Current Transformer 0004-0286-0400
®
Watlow® and DIN-A-MITE Electric Manufacturing Company.
®
UL
and C-UL® are registered trademarks of the Underwriter’s
Laboratories, Inc. Nichrome
®
is a registered trademark of Driver-Harris Company.
are registered trademarks of Watlow
500A : 5A Current Transformer 0004-0286-0500 600A : 5A Current Transformer 0004-0286-0600 800A : 5A Current Transformer 0004-0286-0800 1,000A : 5A Current Transformer 0004-0288-1000 5A : 20mA Interstage Transformer 16-0176
To be automatically connected to the nearest North American Technical Sales Office:
1-800-WATLOW2 • www.watlow.com • inquiry@watlow.com
International Technical Sales Offices: Australia, +61 3 9335 6449China, +86 21 3532 8532France, +33 1 41 32 79 70
Germany, +49 (0) 72 53 / 94 00-0 • India, +91 40 6661 2700 • Italy, +39 024588841 • Japan, +81 3 3518 6630 • Korea, +82 2 2628 5770
Malaysia, +60 3 8076 8745Mexico, +52 442 217 6235Singapore, +65 6773 9488 Spain, +34 91 675 12 92
Taiwan, +886 7 288 5168United Kingdom, +44 (0) 115 964 0777
Loading...