Watlow FLUENT Specifications

High Performance Fluid Heating Solution Featuring Watlow’s Thermal Spray Technology Improves System Performance
SPECIFICATION SHEET
FLUENT® In-line Heater

Features and Benefits

Small, lightweight, robust heater construction
Replaces multiple components in a system
Reduces overall system size
Lowers total cost of ownership
Unique circuit patterning process
Facilitates customizable heating profiles
Enables distributed wattage and/or multiple zones
Assures precise and repeatable power distribution
High watt density, low mass heater
Contributes to fast response time
Allows for efficient heat transfer
Enables on-demand process start-up

Typical Applications

Hemodialysis fluid heating
Food cooking equipment
Semiconductor purge gas heating
Ink preheating systems
On demand fluid heating
Watlow® and FLUENT® are registered trademarks of Watlow Electric Manufacturing Company. UL® and cUL® are registered trademarks of Underwriter’s Laboratories, Inc.
Powered by Possibility
To be automatically connected to the nearest North American Technical Sales Oce:
1-800-WATLOW2 • www.watlow.com
inquiry@watlow.com
©2017 Watlow Electric Manufacturing Company all rights reserved.
International Technical Sales Offices:
China +86 21 3532 8532 France +33 1 41 32 79 70 Germany +49 7253 9400 0 India +91 40 6661 2700
Italy +39 02 4588841 Japan +81 3 3518 6630 Korea +82 2 2169 2600 Mexico +52 442 256 2200
Singapore +65 6773 9488 Spain +34 91 675 1292 Taiwan +886 7 288 5168 UK +44 115 964 0777
STL-FIH-0517

Specifications

Substrate tube material: 444 SS
Fitting and baffle material: 316L SS
Voltage up to 240V
Amperage up to 15A per zone
Resistance tolerance +10%, -5%
Typical maximum watt densities
Air 150 W/in2 (23 W/cm2)
Water 450 W/in2 (70 W/cm2)
Maximum pressure: 150psi (10.2 bar)
Maximum heater temperature: 250°C as measured by
internal Type K T/C
UL®/cUL® (pending) and CE
Optional internal bae to promote turbulent ow and high eciency
Fast responding, high watt density layered heater circuit
Low prole axial lead exit
Standard Product Oering — (5 Day Lead Time)
Protection Tube
Length
Volts Watts
240
500 3.00 (76) 1 210
in. (mm)
120 250 4.25 (108) 1 57 240 1,000 4.25 (108) 1 228 120 375 5.25 (133) 1 62 240 1,500 5.25 (133) 1 247 120 500 6.50 (165) 1 63 240 2,000 6.50 (165) 1 250 120 750 6.50 (165) 2 94 240 3,000 6.50 (165) 2 375 120 1,000 7.75 (197) 2 100 240 4,000 7.75 (197) 2 400 240 500 6.50 (165) 1 63
Note: Go to www.watlow.com/uent for the latest list of standard designs and product information.
Number of
Heating
Circuits
20 AWG UL® 1199 PTFE Insulated Lead Wire
Watt
Density
(W/in2)

Application Orientation

Gas Heating— (Any orientation)
Inlet
Liquid Heating—
(Heater must be vertical with inlet at the bottom)
Outlet

Inlet/Outlet Fitting Options

Ø 0.520 in.
1 in.
0.375 in.
0.520 in.
1
/8 in. Female NPT
Outlet
Inlet
3
Ø
/8 in.
Ø 0.520 in.
Ø
1 in.
1
/4 in.
Inlet Fitting
INLET
Standard Lead Length 12 in.
FLOW DIRECTION
Protection Tube Length
24 AWG Type K T/C Wire
Protection Tube
Outlet Fitting
OUTLET