Watlow FLUENT Quick Start Guide

FLUENT® INSTALLATION
Mounting Orientation
QUICK START GUIDE
FLUENT
Flow direction must always start at the inlet (lead exit) and
®
heater orientation must be vertical for liquids.
flow to the outlet. When mounted vertically, the inlet side should be on the bottom.
Application Orientation
outlet
inlet
GAS
outlet
inlet
GAS
Vertical ApplicationHorizontal Application
Electrical Connection
Temperature Control
The FLUENT heater should not be powered unless fluid
flow is present.
The integrated Type K thermocouple is mounted on the
heating element and should only be used as a high limit sensor with a latching limit control.
The maximum limit temperature setting is 350°C. A lower
setting may be applicable and provide improved product protection.
Fluid temperature sensing must be accomplished by a
downstream sensor.
Minimum High Limit Circuit Requirements
NO
COM
NC
Do not apply more than the recommended voltage
marked on the FLUENT heater.
Grounding to any of the exterior metal components is
recommended.
A heater with multiple heating circuits should have the
circuits connected in parallel and must be powered simultaneously.
SUPPLY VOLTAGE
L1 L2
ELEMENT 2
2-Circuit Wiring Diagram
FUSES
HEAT SHRINK LABELS
ELEMENT 1
MASS FLOW
EARTHING
Contact us at www.watlow.com
thermocouple
INLET OUTLET
FLOW DIRECTION
Other Specifications
Maximum pressure rating: 150 PSI (10.3 bar)
This is intended to be used as a quick start guide. Full
documentation on these and other topics can be found in the product guide at http://fluent.watlow.com/
Loading...