RMA PLUS Remote Access Module
Watlow’s New
RMA PLUS Remote
Access Module Offers
Plug and Play Access to
Powerful EZ-ZONE® RM
Family
SPECIFICATION SHEET
Watlow’s new RMA PLUS remote access module supports
Watlow’s powerful EZ-ZONE® RM temperature controller
family by communicating with and providing access to all
EZ-ZONE RM modules in a system.
EZ-ZONE RMA users have had to spend more time than
desired to connect their entire system. Now the RMA PLUS
offers standard state-of-the-art connectivity from the device
to the entire system. Real-time communication is possible via
a built-in Ethernet switch or USB. Users can also connect to
third-party and legacy devices because the RMA PLUS acts as
a gateway between Modbus® TCP and Modbus® RTU.
The device comes standard with a built-in managed Ethernet
switch with two Ethernet jacks. Up to three Modbus® TCP
sessions, three Watbus over Ethernet sessions and one
Watbus over USB session is available in a single device.
Users can also log up to 16 gigabytes of data standard or
upgrade to a maximum of 32 gigabytes. Configuration and
data logs are available as Windows® files so they can be easily
accessed. In addition, discovery and transfer speeds have
gone from minutes with the legacy EZ-ZONE RMA to just
seconds with the RMA PLUS.
Because the RMA PLUS is an essential component of the
EZ-ZONE RM family, users receive all the benefits and support
of working with Watlow®.
Features and Benefits
Plug and play access to EZ-ZONE RM family
• Integrates easily into existing systems
Built-in Ethernet switch
• Eliminates the need to provide a switch for small systems
• Offers port mirroring for troubleshooting
• Protects from broadcast and multicast storms
Integrated USB connection
• Provides easy connection from PC with no converter
• Ensures real-time communication from software packages
Modbus® TCP and Modbus® RTU
• Allows users to build tables based on individual needs
• Connects to third-party and legacy devices
Data logging
• Offers users the opportunity to log any data point in the
system
Specifications
(Select a RMA PLUS module for communication protocol
options, data logging and system conguration)
Interoperable with:
• EZ-ZONE RM (C, E, H, L, S) version 9.0+ (high-speed Watbus)
• EZ-ZONE RM (A, C, E, H, L, S) (low-speed Watbus)
• EZ-ZONE PM, RUI, ST (low-speed Watbus)
• EZ-ZONE RM (F, G, UH, Z)
• POWERGLIDE™
Line Voltage/Power
• Power consumption: 4 W, 9VA
• Any external power supply used should comply with a
Class 2 or SELV rating
Isolated Serial Communications
• All modules ship with standard bus protocol (Watbus)
for conguration and communication connection to all
EZ-ZONE products
Standard Communication
• Watbus over Ethernet (gateway to high-speed Watbus)
• Watbus over USB (gateway to high-speed Watbus)
• Watbus via Serial (‘C’ connector)
• Modbus® TCP
Additional Communication Options
• EIA 232/485, Modbus® RTU
• DeviceNet™ (future option)
• EtherNet/IP™ (future option)
USB
• USB 2.0 device
• Mini USB connector type
• Recognized as a composite device: vendor specic and mass
storage classes
• USB host (future option)
Real Time Clock with Battery Backup
• Accuracy (typical): +/- 30ppm at 77°F (25°C)
• +30/-100ppm overtemperature operating range
• Battery type and typical lifetime rating: 10 years at
77°F (25°C)
• Lithium battery used, recycle properly
Data Logging
• Maximum of 2000 valid records
• Maximum of 500 unique data points per Watbus bus
and zone
• File storage on embedded micro SD memory
• Comma separated value (CSV) le type
• Access log les via USB device port
Memory Card
• Micro SDHC (4-32GB)
• 4GB class 4 SDHC on standard models (operating
temperature: -25 to 85°C)
• 16GB class 10 SDHC on data log models (operating
temperature: -40 to 85°C)
• -4 to 185°F (-20 to 85°C) ambient rating, non-volatile
memory
Note: All module parameters are backed up in memory.
Configuration Code
Module for communications, data logging and storage. Comes standard with Modbus® TCP, standard bus over Ethernet, USB device,
internal storage and SD card.
① ② ③ ④
Rail Mount
Access Module
RMAP
⑤
A =
None
2 =
Modbus® RTU 232/485
5 =
DeviceNet™ (future option)
⑥
A =
None
1 =
18 T/C scanner inputs (future option)
2 =
18 T/C limit inputs with one global relay output (future option)
⑦
A =
None
D =
Data logging to 16G SD card
⑧
A =
None
B =
Bluetooth® (future option)
W =
Wi-Fi (future option)
–
Additional Communication Protocols
Ultra High Density T/C Input Card
⑤
Additional
Communication
Protocols
Data Logging
Wireless Connectivity
⑥
Ultra High Density
Thermocouple
Input Card
⑦
Data
Logging
⑧
Wireless
Connectivity
⑨
A =
⑩
A =
⑪ ⑫
AA =
XX =
Watlow® and EZ-ZONE® are registered trademarks of Watlow Electric
Manufacturing Company.
Modbus® is a registered trademark of Schneider Automation Incorporated.
Windows® is a registered trademark of the Microsoft Corporation.
Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.
POWERGLIDE™ is a trademark of Watlow Electric Manufacturing Company.
DeviceNet™ and EtherNet/IP™ are trademarks of Open DeviceNet Vendors Association.
⑨
Future
Option
A
–
Future option
Future option
Standard
Custom/locked code application specic
⑩
Future
Option
A
⑪ ⑫
Additional
Options
Future Option
Future Option
Additional Options
Powered by Possibility
To be automatically connected to the nearest
North American Technical Sales Oce:
1-800-WATLOW2 • www.watlow.com
inquiry@watlow.com
©2019 Watlow Electric Manufacturing Company all rights reserved.
International Technical Sales Offices:
Austria +43 6244 20129 0
China +86 21 3532 8532
France +33 1 41 32 79 70
Germany +49 7253 9400 0
India +91 40 6661 2700
Italy +39 02 458 8841
Japan +81 3 3518 6630
Korea +82 2 2169 2600
Mexico +52 442 256 2200
Singapore +65 6773 9488
Spain +34 91 675 1292
Taiwan +886 7 288 5168
UK +44 115 964 0777
WIN-RMAPLUS-0419