EZware-5000 Software
Product Enhancement: Versi o n 4. 65.11

Date: March 26, 2014 Product Description

The EZware-5000 software suite is used to create, edit and manage projects for Silver Series operator interface terminals (OIT). The suite includes the EasyConverter, EasyBuilder5000, Project Manager and Recipe Editor programs.

EZware-5000 Software Version 4.65.11 Update

This new version replaces the previous version (4.65.07) and is compatible with these Silver Series OITs offered by Watlow
®
:
TS00-0043-0000: 4.3 inch touchscreen with USB device and 2 serial ports
TS00-0043-E000: 4.3 inch touchscreen with Ethernet and 2 serial ports
TS00-0070-0000: 7 inch touchscreen with USB device and host ports, Ethernet and 3 serial ports
TS00-0100-0000: 10 inch touchscreen with USB device and host ports, Ethernet and 3 serial ports
For a full list of updates see What’s New in EZware-5000’s on-line help.

New Program and Screen Object Features

®
The Modbus
RTU/TCP driver provides a slave gateway allowing the OIT to automatically route Modbus® data to any controller or OIT address used in the OIT project. Note: tag-based PLC projects are not supported by the gateway.
Objects on Underlay Windows can be shown or hidden while editing a project using an option on the Preferences dialog (from the Option menu, choose Preferences…)
Added a new system register, LB12050. Bit is on when an SD card is present.
®
The Allen-Bradley
Tools utility programs, ABAddressImporter and Structure Editor are now included.

New Communications Driver

Mitsubishi
®
L6ADP

New Communications Driver Features

The BACnet
®
driver now supports user-specified settings for Maximum Number of Segments Accepted,
Maximum ADPU Length Accepted, and Ultimate Destination MAC Layer Address.

Program Fixes

®
Macros: The SetData() function works properly with the Allen-Bradley
Compact/ControlLogix® Free Tags
(EthernetIP-CIP Preferred) driver and tags in the processor main task.
Pass-through Virtual Com Port works properly under 64-bit Windows.
The error message, "The text will exceed the size", can now be closed when the specified text does not fit in
a 'pinned' object.
The Binary Access feature in the Structure Editor now works properly.
The (sequence of events) SOE Display object data is properly retained after changing to another window.
An extra menu is no longer displayed after right-clicking a window thumbnail in the Window Tree.
Extra dots (.) in the project filename no longer cause the compiler to generate incorrect font filenames.
/CONTINUED/
Watlow • 1241 Bundy Boulevard • Winona, MN 55987 USA • Phone: 507-454-5300 • Fax: 507-452-4507
Doc. 7250-003 Rev. E
Page 2 of 3
The message, “Windows® 8 (Storage Space Insufficient)”, no longer appears when the USB or SD device is not present, and Data Sampling or Event Logging is started within 5 seconds of the HMI starting up.

Communications Driver Fixes

®
The Allen-Bradley
DH485 driver now works properly with the SLC5/03 processor.
The Animatics SMC driver no longer behaves erratically for a few seconds after the HMI writes data to the smartmotor.
®
The Omron EasyBuilder project.
Ethernet/IP driver now works properly when a large number of PLC addresses is used in the
The address type of an imported Beckhoff® Twincat® 3 tag is now mapped correctly.
How to Upgrade: EZware-5000 is available as a free-of-charge download from the Watlow website (see Collateral below) and is also available on the Controller Support Tools DVD-ROM (see List Prices below).
Regarding Projects Made with Earlier Versions: Projects created with previous versions must be compiled and downloaded with the new version of EasyBuilder5000 to benefit from any of the listed updates. To make sure the OIT has the latest firmware, select the firmware option the first time you download the project.

Operating System Compatibility

®
Microsoft
Windows® 7, 8, Vista and XP
List Price: $1.00 0600-0001-0000 Controller Support Tools DVD-ROM (see Effective Dates) Effective Dates: Available at www.watlow.com: March 26, 2014

Controller Support Tools DVD-ROM: est. June, 2014 Collateral

Data Sheet: http://www.watlow.com/downloads/en/specsheets/winoit0214.pdf
Updated: EZware-5000 software download: http://www.watlow.com/downloads/en/software/ezware.cfm
Updated: Silver Series Installation and Operation Manual: http://www.watlow.com/downloads/en/manuals/ssoime_c.pdf
Silver Series OIT Installation G ui de: http://www.watlow.com/downloads/en/manuals/ssig_d.pdf
Watlow Addendum to Installation and Operation Manual: http://www.watlow.com/downloads/en/manuals/ssae_d.pdf
Sample EZ-ZONE® PM Project (800 x 480): http://www.watlow.com/downloads/en/software/ssapp01_c.zip
Sample EZ-ZONE RM Project (800 x 480): http://www.watlow.com/downloads/en/software/ssapp02_d.zip
Sample EZ-ZONE ST Project (800 x 480): http://www.watlow.com/downloads/en/software/ssapp03_d.zip
Sample Barcode Reader Project (800 x 480): http://www.watlow.com/downloads/en/software/ssapp04_c.zip
Sample EZ-ZONE RM Sample Project (480 x 272) 485: http://www.watlow.com/downloads/en/software/ssapp05_a.zip
Sample EZ-ZONE RM Sample Project (480 x 272) Ethernet: http://www.watlow.com/downloads/en/software/ssapp06_a.zip
Frequently Asked Questions: http://www.watlow.com/downloads/en/training/ssfaqe_c.pdf
Silver Series Secrets 1: Using a Sample Project: http://www.watlow.com/downloads/en/training/ss01b.wmv
Silver Series Secrets 2: Modbus® TCP via an EZ-ZONE Gateway: http://www.watlow.com/downloads/en/training/ss02_a.wmv
Silver Series Secrets 3: Modbus® RTU via an EZ-ZONE Gateway: http://www.watlow.com/downloads/en/training/ss03_b.wmv
Silver Series Secrets 4: Modbus® TCP Communications w/o a Gateway: http://www.watlow.com/downloads/en/training/ss04_a.wmv
Silver Series Secrets 5: Modbus® RTU Communications w/o a Gateway: http://www.watlow.com/downloads/en/training/ss05_a.wmv
Silver Series Secrets 6: Logging Data from EZ-ZONE Products: http://www.watlow.com/downloads/en/training/ss06_a.wmv
Silver Series Secrets 7: Graphing Data from EZ-ZONE Products: http://www.watlow.com/downloads/en/training/ss07_a.wmv
Instructions for remotely monitoring a Silver Series OITs over a network or over the internet:
http://www.watlow.com/downloads/en/whitepapers/remote%20oit.pdf
/CONTINUED/
Watlow • 1241 Bundy Boulevard • Winona, MN 55987 USA • Phone: 507-454-5300 • Fax: 507-452-4507
Loading...
+ 1 hidden pages