Watlow E-Safe Hybrid Relay User Manual Rev B

E-SAFE Relay
User’s Manual

Safety Information

We use note, caution and warning symbols throughout this book to draw your attention to important operational and safety information.
A “NOTE” marks a short message to alert you to an important detail.
A “CAUTION” safety alert appears with information that is important for protecting your equipment and performance. Be especially careful to read and follow all cautions that apply to your application.
A “WARNING” safety alert appears with information that is important for protecting you, others and equipment from dam­age. Pay very close attention to all warnings that apply to your application.
The safety alert symbol, ç (an exclamation point in a trian­gle) precedes a general CAUTION or WARNING statement.
The electrical hazard symbol, Ó (a lightning bolt in a trian­gle) precedes an electric shock hazard CAUTION or WARN­ING safety statement.

Technical Assistance

If you encounter a problem with your Watlow controller, review your configuration information to verify that your selections are consistent with your application: inputs; out­puts; alarms; limits; etc. If the problem persists after checking the configuration of the controller, you can get technical assis­tance from your local Watlow representative (see back cover), or in the U.S., dial +1 (507) 454-5300. For technical support, ask for for an Applications Engineer.
Please have the following information available when calling:
• Complete model number • User’s Manual

Your Comments

We welcome your comments or suggestions on this user’s manual. Please send them to: Technical Writer, Watlow Winona, 1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota, USA 55987-5580; telephone: +1 (507) 454-5300; fax: +1 (507) 452-4507. © Copyright 2001 by Watlow Winona, Inc. (2143) All rights reserved.
1241 Bundy Boulevard, Winona, Minnesota USA 55987-5580
Phone: +1 (507) 454-5300 Fax: +1 (507) 452-4507
Internet: http://www.watlow.com
Hybrid Relay
English
Rev C February, 2004
ç
CAUTION or
WARNING
Ó
Electrical
Shock Hazard
CAUTION or
WARNING

About Watlow Winona

Watlow Winona is a U.S. division of Watlow Electric Mfg. Co., St. Louis, Missouri, a manufacturer of industrial electric heating products since 1922. Watlow products include electric heaters, sensors, controllers and switching devices. The Winona operation has been designing solid-state electronic control devices since 1962, and has earned the reputation as an excellent supplier to original equipment manufacturers. These OEMs and end users depend upon Watlow Winona to provide compatibly engineered controls that they can incorporate into their products with confidence. Watlow Winona resides in a 100,000-square-foot marketing, engineering and manufacturing facility in Winona, Minnesota.

Warranty

The Watlow E-Safe Relay is warranted to be free of defects in material and workmanship for 18 months after delivery to the first purchaser for use, providing that the units have not been misapplied. Since Watlow has no control over their use, and sometimes misuse, we cannot guarantee against failure. Watlow's obligations hereunder, at Watlow's option, are limited to replacement, repair or refund of purchase price, and parts which upon examination prove to be defective within the warranty period specified. This warranty does not apply to damage resulting from transportation, alteration, misuse, or abuse.

Returns

• Call or fax your distributor or the nearest Watlow sales office for best information about returns. (See outside back cover.)
• To return directly to Watlow Winona in the U.S., first call or fax Customer Service for a Return Material Authorization (RMA) number (telephone: +1 (507) 454-5300; fax: +1 (507) 452-4507).
• Put the RMA number on the shipping label, along with on a written description of the problem.
• A restocking charge of 20% of the net price is charged for all standard units returned to stock.
United States ( headquarters)
Watlow Electric Manufacturing Co. 12001 Lackland Road St. Louis, Missouri, USA 63146 Telephone: +1 (314) 878-4600 Fax: +1 (314) 878-6814
Europe:
Watlow GmbH Lauchwasenstr. 1, Postfach 1165, Kronau 76709 Germany Telephone: +49 (0) 7253-9400-0 Fax: +49 (0) 7253-9400-44
Watlow France S.A.R.L. Immeuble Somag,16 Rue Ampère, Cergy Pontoise Cedex 95307 France Telephone: +33 (01) 3073-2425 Fax: +33 (01) 3073-2875
Watlow Italy S.r.l. Via Meucci 14, 20094 Corsico, Milano, Italy Telephone: +39 (02) 458-8841 Fax: +39 (02) 458-69954
Watlow Limited Robey Close, Linby Industrial Estate, Linby, Nottingham NG15 8AA England Telephone: +44 (0) 115-964-0777 Fax: +44 (0) 115-964-0071
Latin America:
Watlow Mexico Avenue Fundición #5, Col. Parques Industriales, Querétaro, Qro. México CP-76130 Telephone: +52 (42) 17-6235 Fax: +52 (42) 17-6403
Asia/Pacific:
Watlow Australia Pty., Ltd. 3 Belmont Place, Gladstone Park, Tullamarine, Victoria 3043 Australia Telephone: +61 (3) 9335-6449 Fax: +61 (3) 9330-3566
Watlow China Shanghai Representative Office 179, Zhong Shan Hong Qiao Cointek Bldg, Fl. 4, Unit P Shanghai 200051 China Telephone: +86 (21) 6229-8917 Fax: +86 (21) 6228-4654
Watlow Japan Ltd. K.K. Azabu Embassy Heights 106, 1-11-12 Akasaka, Minato-ku, Tokyo 107-0052 Japan Telephone: +81 (3) 5403-4688 Fax: +81 (3) 3 5575-3373
Watlow Korea 3rd Fl. Han-il Bldg. 210-5 YangJae-dong, SeoCho-ku Seoul, 137-893 Korea Telephone: +82 (02) 575-9804 Fax: +82 (02) 575-9831
Watlow Malaysia Sdn Bhd 38-B Jalan Tun Dr. Awang Bayan Lepas Penang, Malaysia 11900 Telephone: +60 (4) 641-5977 Fax: +60 (4) 641-5979
Watlow Asia Engineering Pte. Ltd. 16, Ayer Rajah Crescent, #06-05A, Ayer Rajah Industrial Estate, Singapore 139965 Telephone: +65 6777-1266 Fax: +65 6777-7662
Watlow Electric Taiwan Corp. 10F-1 No. 189, Chi-Shen 2nd Road, Kaohsiung, Taiwan Telephone: +886 (07) 288-5168 Fax: +886 (07) 288-5568

How to Reach Us

For other product information:
Watlow FAX REPLY: +1 (732) 885-6344, outside the U.S.; or +1 (800) 367-0430, inside the U.S.
6 0 9 4 7
S i d e
F r o n t
Top & Bottom

Unit Dimensions

ç
CAUTION: Provide proper enclosure ventilation to maintain an operating environment <55°C maximum ambient rating. Failure to do so could cause damage to equipment and property.

E-SAFE Relay in Operation

Off
On
Off
Conduction Path
ç
WARNING: Wiring must conform to National Electric Code (NEC) safety standards, as well as locally applicable codes. Failure to do so could result in per­sonal injury or death.
W A R N I N G : Only authorized and qualified personnel should install and service the E-SAFE relay. Failure to comply with these r e c o m m e n d a t i o n s may result in damage to equipment and property and injury to p e r s o n n e l .
System Wiring Example

Input and Output Wiring

Torque Guidelines :
• Properly torgued line & load terminals to 3.95 nm (35 in-lbs)
• Retorque after 48 hours to minimize wire cold flow.
• Re-torque line & load terminals every 36 months.
Declaration of Conformity
Series E-Safe Relay
Watlow Winona, Inc. 1241 Bundy Blvd. Winona, MN 55987 USA
Declares that the following product:
Designation: Series E-Safe Model Numbers: ES (20 or 40) - 3 (024, 120, 220) - ACCE Classification: Mechanical Relay, AC-51 Utilization
Category for Resistive Loads. Installation Category II, Pollution degree 2
Rated Voltage and Frequency: Load 24-240 V~(ac) 50/60 Hz,
Control Signal 24 V~, 120 V~ or 200-240V~
Rated Power Consumption: Load 20 A or 40 A depending on model.
Control Signal 15 VA Max.
Meets the essential requirements of the following European Union Directives by using the relevant standards show below to indicate compliance.
89/336/EEC Electromagnetic Compatibility Directive
EN 60947-4-3 2000 Low-voltage switchgear and controlgear - Contactors and
motor-starters - AC semiconductor controllers and contactors for non-motor loads. Industrial Immunity, Class B emissions.
EN 61000-4-2 1995 Electrostatic Discharge Immunity EN 61000-4-3 1996 Radiated Field Immunity EN 61000-4-4 1995 Electrical Fast-Transient / Burst Immunity EN 61000-4-5 1 9 9 5 , A 1 : 1 9 9 6 Surge Immunity EN 61000-4-6 1996 Conducted Immunity EN 61000-4-11 1994 Voltage Dips, Short Interruptions and Voltage Variations Immunity EN 61000-3-2 2000 ED.2. Harmonic Current Emissions
73/23/EEC Low-Voltage Directive
EN 60947-4-3 2000 Low-voltage switchgear and controlgear- Contactors and
motor-starters - AC semiconductor controllers and contactors for non-motor loads.
Raymond D. Feller III Winona, Minnesota, USA Name of Authorized Representative Place of Issue
General Manager February 2004 Title of Authorized Representative Date of Issue
Signature of Authorized Representative

Ordering Information

(2145)
Part Number E S _ _ - _ _ _ _ - _ _ _ _
Amperage
20 = 20 amp 40 = 40 amp
Number of Poles
3 = 3-pole
Control Voltage
024 AC = 24 V~ 120 AC = 120 V~ 220 AC = 220 V~
Label Options
00 = Standard Product CE = With CE mark

Specifications

(2146)
Control Mode
• Zero cross switching output
• Form A outputs, without arcing
• Cycle rate: 30 cycles per minute, maximum
Input Command Signal
• 24V~ (+10% / -10%) @ 0.375 Amperes
• 120V~ (+10% / -10%) @ 0.075 Amperes
• 220V~ (+15% / -20%) @ 0.041 Amperes
• 50/60 Hz
• Input Surge current and pulse characteristics 24 volt input = 24 Amp surge, less than 10VA required (0.41 A) 120 volt input = 16 Amp surge, less than 12VA required (0.101 A) 220 volt input = 8 Amp surge, less than 14VA required (0.063 A)
• Power factor approximate 0.58, 100 uSec pulse width or surge.
Note: Do not use a RC snubber on the Esafe input or the temperature con­trol command signal output
Output Rating
• 20A to 40A max. per pole into a resistive load,
model number dependent
• 208/240V, 50/60 Hz, phase to phase
• 3-pole
• Leakage current: 0.5mA max.
Operating Life
• 1,000,000 switching cycles at maximum rating
Weight/Dimensions
• Weight: 0.560 Kg (1.25 lb)
• 96.0 mm (3.78 in) high x 82.3 mm (3.24 in) wide
x 90.2 mm (3.55 in) deep
Terminals
• Control input: Compression, accept 0.2 to 6 mm2(# 22 -10 AWG)
wire, torque to 0.8 Nm (7 in-lbs) maximum
• Output: Compression, accept 2.5 to 16 mm2(# 14- 6 AWG) wire,
torque to 3.95 Nm (35 in-lbs) maximum
Operating Environment
• Operating temperature, -30 to 55°C/-22 to 130°F
• 5 to 85% RH, non-condensing
• Storage temperature, -40 to 85°C/-40 to 185°F
Mounting
• Fits footprint of definite purpose relays and most 30 to 50 amp
mercury relays
Agency Approvals
• UL® 508 listed, C-UL, File #E213822
Quality and Mission Statement:
Watlow Winona will be the world’s best supplier of superior thermal solu­tions by exceeding the expectations of our customers, shareholders, and employees.
Your Authorized Watlow Distributor:
Loading...