DIN-A-MITE® A
The DIN-A-MITE® A power controller provides a low-cost, highly compact and versatile solid state option for controlling electric heat. This controller is designed and manufactured with the quality features expected from Watlow®. DIN-rail and panel mounting is standard on every controller. There is no need to worry about mercury, the DIN-A-MITE controller is mercury free.
Features include single-phase zero cross switching up to 25 amperes at 600VAC (see rating curve). A unique integrated design removes the guesswork associated with selecting a proper heat sink and adequate terminations for the application.
Variable time-base, 4-20mA process control and VAC/VDC input contactor versions are available. All options are model number dependent and factory configurable. This power controller also includes 200KA short circuit current rating (SCCR) tested up to 480VAC to minimize damage in the event of a short circuit when used with required fusing.

Features and Benefits

200KA SCCR with proper fusing
Minimizes damage in the event of a short circuit
DIN-rail and panel mounting
Provides versatility and quick, low-cost installation
Compact size
Reduces panel space and cost
Touch-safe terminals
Increases safety for installer and user
Mercury free
Assures environmental safety
Faster switching with solid state
Saves energy and extends heater life
UL® 508 listed, C-UL®, RoHS 2 and CE with filter
Meets applications requiring agency approval
Reduces end product documentation cost
Back-to-back SCR design
Ensures a rugged design
Watlow® and DIN-A-MITE® are registered trademarks of Watlow Electric Manufacturing Company.
UL® and C-UL® are registered trademarks of the Underwriter’s Laboratories, Inc.
Powered by Possibility
To be automatically connected to the nearest North American Technical Sales Oce:
1-800-WATLOW2 • www.watlow.com
©2016 Watlow Electric Manufacturing Company all rights reserved.
inquiry@watlow.com
International Technical Sales Offices:
China +86 21 3532 8532 France +33 1 41 32 79 70 Germany +49 7253 9400 0 India +91 40 6661 2700
Italy +39 02 4588841 Japan +81 3 3518 6630 Korea +82 2 2169 2600 Mexico +52 442 256 2200
Singapore +65 6773 9488 Spain +34 91 675 1292 Taiwan +886 7 288 5168 UK +44 115 964 0777
WIN-DMA-1216
Current (Amperes) into

Specifications

Operator Interface
• Control input
• Input indication LED
Amperage
• Single-phase, see the output rating curve
• Max. I2t for fusing: 4000A2sec
• Latching current: 400mA max.
• Holding current: 200mA max.
• Power dissipation is 1.2 watts per ampere switched
• 200KA SCCR, Type 1 and 2 approved with the recommended fusing; see user manual.
Line Voltage
• 24 to 660VAC model number dependent; see ordering information
• Off-state leakage: 1mA at 77°F (25°C) max.
• 50/60Hz independent
Control Mode, Zero Cross
• Control option C: VDC input, contactor output
• Control option K: VAC input, contactor output
• To increase service life on contactor models, the cycle time should be less than three seconds
• Control option F: 4 to 20mA DC input, variable time-base control output (3 cycles on, 3 cycles off at 50% power)
Control Input
• AC contactor: 24VAC ±10%, 120VAC +10/-25%, 240VAC +10/-25% @ 25mA max.
DC contactor: 4.5 to 32VDC: max. current @ 4.5VDC is 8mA
Loop powered linear current 4 to 20mA DC: loop-powered, control option F0 only (requires current source with 8.0VDC available, no more than two DIN-A-MITE inputs can be connected in series)
Agency Approvals
• CE with proper filter:
204/108/EC Electromagnetic Compatibility Directive EN 61326-1: Industrial Immunity Class A Emissions 2006/95/EC Low Voltage Directive EN 50178 Safety Requirements Installation category III, pollution degree 2
UL® 508 listed and C-UL® File E73741
• 2011/65/EU RoHS 2
Control Input Terminals
• Compression: will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire
Line and Load Terminals
• Compression: will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire
Operating Environment
• -4 to 176°F (-20 to 80°C); see the output rating curve chart for your application
• 0 to 90% RH (relative humidity), non-conden sing
• Insulation tested to 3,000 meters
• Units are suitable for “Pollution degree 2”
Mounting
Options include DIN-rail or standard back panel mounting
• DIN EN 50022, 35 mm by 7.5 mm
• Mount cooling fins vertically
Dimensions
• 3.7 in. (94 mm) high x 2.0 in. (50 mm) wide x 3.9 in. (98 mm) deep
• Weight: 0.71 lb (0.32kg)
Specifications are subject to change without notice.

Output Rating Curve

30
25
20
a Resistive Load
15
10
5
0
DIN-A-MITE Style A Ratings at 100% On
25 30 35 40 45 50 55 60 65 70 75 80 85
Max. Internal Enclosure Ambient Temperature (°C)

Ordering Information

Part Number
D
1 = 1-phase, 1 controlled leg
0 = Natural convection current rating 18A @50°C
⑤ ⑥
02 = 24 = 60 =
⑦ ⑧
C0 = F0 = K1 = K2 = K3 =
A
Cooling and Current Rating (see rating curve)
24 to 48VAC 120 to 240VAC 277 to 600VAC
4.5 to 32VDC input, contactor output 4 to 20mA DC input, variable time-base output 22 to 26VAC input, contactor output 100 to 120VAC input, contactor output 200 to 240VAC input, contactor output
Phase
1
Line and Load Voltage
Cooling &
Current
Rating
0
Phase
Control
⑤ ⑥
Line &
Load
Voltage
⑦ ⑧
Control
0
⑪ ⑫
00 = XX =
User
Manual
0 =
English
1 =
German
2 =
Spanish
3 =
French
Standard part Any letter or number, custom options
⑪ ⑫
Custom Options
User Manual
Custom Options
Recommended Fuses and Fuse Holders
Semiconductor Fuses and Holders
Part Nbr. Description
17-8025 25A fuse 17-5110 10-25A holder
DFJ Combination Fuses and Holders
Part Nbr. Description
0808-0325-0020 0808-0325-0030 0808-0326-1530
20A fuse 30A fuse
15-30A holder
Loading...