Water Inc BG-3000S, BG-3000R User Manual

Cartridge Change Instructions:
BG-3000S/BG-3000R
Homeowner: Please retain for operation and future maintenance instructions.
Approximate edge of paper shown here. Final size is 78% smaller than shown, booklet format.
Internationally Distributed by Water, Inc.
Carson, CA 90746
1-800-322-WATER (9283)
http://bodyglove.waterinc.com
W-861 Rev 08/08
SAFETY INFORMATION
Please read and follow all safety information contained in these instructions prior to use of the Body Glove BG-3000R Replacement Cartridge. Retain these instructions for future reference.
Intended use: The BG-3000R Cartridge is intended for use in filtering potable water in homes and has not been evaluated for
other uses.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
CAUTION
To reduce the risk associated with ingestion of contaminants due to use with water that is microbiologically unsafe or of unknown quality:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
To reduce the risk associated with property damage due to water leakage:
Read Instructions before use of this cartridge.
• Installation and use MUST comply with all state and local plumbing codes.
Protect from freezing, remove filter cartridge when ambient temperatures are expected to drop below 40° F (4.4° C).
Do not install replacement cartridge if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa),
you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
Do not use pliers or a pipe wrench to tighten when installing replacement cartridge.
• Ensure that the location and fasteners will support the weight of the system with water when installed.
• Ensure all tubing and ttings are secure and free of leaks.
• For the cartridge to be properly installed on metal ring models and to prevent accidental cartridge disengagement from head unit, the
valve handle MUST engage the lock lug on the metal ring.
• The disposable lter cartridge MUST be replaced every twelve months, at the rated capacity or if there is a noticeable reduction in
flow rate, whichever occurs first.
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
WARNING
IMPORTANT NOTES
• Failure to follow instructions may void warranty.
FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
To maximize effectiveness and to help reduce the possibility of service related issues, the disposable, environmentally friendly & recyclable filter cartridge must be replaced every twelve months. Water, Inc values your choice in the highest quality water treatment. Failure to follow these instructions may void your warranty and increase the risk of incidental water or property damage.
Filter Cartridge Removal Instructions (Ringless Models)
1. Place towel under filter to collect any residual water during cartridge change-out.
2. Locate shut-off. Some models have the valve on top of head unit and shut off water source by rotating valve handle fully counter-clockwise. Others have a shut-off upstream before the filter.
3. Open drinking water faucet at sink to relieve pressure and affirm water source is shut off. Close drinking water faucet.
4. Grasp head firmly. Turn cartridge to the left until cartridge stops.
5. Gently pull cartridge downward and away from the head to remove.
Cartridge Installation (Ringless Models)
6. Remove RED sanitary protective cap from new cartridge.
7. Ensure that o-rings are present on the cartridge and are seated into grooves; moisten o-rings with water. DO NOT use any
petroleum products to lubricate the o-rings.
8. Again grasp head firmly.
9. Line-up the cartridge arrow indicated in red with the label on the head unit and push upward. (line-up either cartridge lugs with the head label and push upward).
10. Turn the cartridge to the right 90 degrees until cartridge stops.
11. Turn on water inlet valve and inspect for any leaks. Turn on water by rotating the valve handle clockwise until it stops.
12. Open faucet and run water for a minimum of 4 gallons (approximately 5 minutes) to flush system of carbon fines and release trapped air. Flush water into a bucket or pail and reuse the water for garden or landscape watering. While system is flushing, check for leaks. Repair any leaks as needed before continuing.
13. Close filter system faucet. System is now under pressure and can be inspected for leaks. Repair any leaks as needed before continuing. The system is now ready for use.
14. Please review section “Water Filter Replacement Indicator” for instructions on how to activate and/or test this device.