POWER ....................................................................................................................................................................... 5
SALT CAPACITY &EFFICIENCY ................................................................................................................................. 5
UNPACKING AND INSPECTION .................................................................................................................................... 6
WHERE TO INSTALL THE SOFTENER ........................................................................................................................... 6
4.BRINE FILL ........................................................................................................................................................... 11
SERVICE ................................................................................................................................................................... 12
CLEANING IRON OUT OF THE WATER SOFTENING SYSTEM ...................................................................................... 12
CHECKING FOR A SALT BRIDGE ............................................................................................................................... 12
BREAKING A SALT BRIDGE ...................................................................................................................................... 12
CLEANING THE INJECTOR AND SCREEN .................................................................................................................... 12
WATER SOFTENER SYSTEM PARTS LIST ...................................................................................................... 15
LIMITED WARRANTY ........................................................................... ERROR! BOOKMARK NOT DEFINED.
Tested and Certified by the WQA against NSF/ANSI Standard 44 & 372 & CSA B483.1.
Page 2 of 18
Water Softener
Important Safety Information – Read All
CAUTION: Read and follow the information in this manual to
minimize the risk of electric shock or personal injury.
IMPORTANT! If you are unsure about installing you’re WATER
!
Instructions Before Using
Before beginning installation, read these instructions completely. Then obtain all the materials
and tools needed for installation.
NOTE: Failure to install the WATER DOCTORS system correctly voids the warranty.
Perform installation according to state and local plumbing codes.
- Use only lead-free solder and flux for sweat-solder connections, as required by state and
federal codes.
Handle all components of the WATER DOCTORS system with care. Do not drop, drag o r turn
components upside down.
Be sure the floor under the water softening system is clean and level.
The WATER DOCTORS system uses 24 volt-60Hz electrical power. Always use the transformer
supplied.
- Plug transformer into an indoor 120 volt, grounded outlet.
- Properly ground WATER DOCTORS system to conform with all codes and ordinances.
Install WATER DOCTORS system in a protected area. Be sure electric outlet and transformer do
not come in contact with water. See Where to Install the Softener, in the installation section of the
manual.
- Do not attempt to treat water over 110°F with the WATER DOCTORS system. Always
connect the WATER DOCTORS system to the main water supply pipe before water
heater.
- Do not expose this WATER DOCTORS system to freezing temperatures. Water freezing
in the system will cause equipment damage.
- Do not install in direct sunlight. Heat from sun may cause damage.
Minimum inlet water pressure is 20 psi. Maximum inlet water pressure is 125 psi. Use pressure
reducing valve if necessary.
Sodium used in the water softening process should be considered as part of your overall dietary
salt intake. Contact physician if you are on a low sodium diet.
Use clean water softening salts only, at least 99.5% pure. Failure to use the correct salt may
create a health hazard or maintenance problems.
- Pellet or coarse solar salt are the preferred salt choice. Rock salt is acceptable but will require
more brine tank maintenance
- Do not use granulated or ice cream making salts.
Always keep the salt lid in place unless servicing the unit or replenishing salt.
Page 3 of 18
!
DOCTORS water softener, contact the Pentair Water Treatment helpline
or consult a professional plumber.
IMPORTANT! This system must be installed in compliance with
applicable state and local codes, law, and regulations.
CAUTION:
Do not use with water that is unsafe or of unknown quality.
Test water periodically to verify that the system is performing
satisfactorily.
Discard small parts remaining after the installation.
Water Softener
Softener Anatomy
1
2
3
4
5
1…………… Valve
2…………… Bypass
3…………… Resin Tank
4…………… Distributor
5…………… Resin
6…………… Salt/Brine Tank Lid
7…………… Salt/BrineTank
8…………… Faceplate/Controls
Not Shown Brine Valve Assembly
8
6
7
Figure 1
Page 4 of 18
Water Softener
Specifications
Feedwater
! Do not use this system on water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. !
Minimum inlet pressure: 20 psig
Maximum outlet pressure: 125 psig
Minimum water temperature: 34 degrees F
Maximum water temperature: 110 degrees F
Power
Voltage: 120VAC
Frequency: 60Hz
Power consumption: 7 Watts Maximum
Installation
Location: In or outdoors (Protect from direct sunlight if installed outdoors)
Minimum ambient temperature: 34 degrees F
Maximum ambient temperature: 120 degrees F
Salt Capacity & Efficiency
All Models 400 lbs (181 Kg)
The Efficiency Rating of these systems is only valid at the stated salt dosage and maximum service flow rate.
The Efficiency was determined in accordance with NSF/ANSI 44
This unit conforms to NSF/ANSI-44 for specific performance claims as verified
and substantiated by test data. Refer to NSF Compliance Data Insert for
further information. Contact
WATER DOCTORSfor additional copies.
Page 5 of 18
Water Softener
Setup
Unpacking and Inspection
Check the WATER DOCTORS system compone nts for damage or missing parts.
Where to Install the Softener
Consider the following points when determining where to install the water softener:
Place the WATER DOCTORS system as close as possible to a sewer drain.
Do not install the softener where it would block access to the water heater, or access to the main water
shutoff, water meter, or electrical panels.
Keep outside faucets on hard water to save soft water and salt.
Install the softener in a place where water damage is least likely to occur if a leak develops.
A 120V electrical outlet is needed to plug in the transformer. If the outlet is remote (up to 100 feet), use 18
gauge wire to connect.
Always connect the WATER DOCTORSsystem to the main water sup ply pipe before the water heater.
Install the WATER DOCTORS system where it will not be subject to temperatures out side of the limits
stated in the Specification section or to direct sunlight.
Hardness Setting
Municipal Water
WATER DOCTORS recommends that you call your local water company to determine your water hardne ss in
grains per gallon and iron in mg/l (or ppm).
Well Water
WATER DOCTORS recommends that you have your water tested professionally for accurate hardness and iron
content.
Page 6 of 18