Waterco MultiCyclone 70XL User Manual

www.waterco.com
Notice to Installer
This manual contains important information about the installation, operation and safe use of this product. Once the product has been installed this manual
must be given to the owner / operator of this equipment.
This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could result in property damage, serious injury or death. Improper installation will void the warranty.
WARNING
!
70XL
Manual
SAFETY INFORMATION ------------------------------------------- 00
INTRODUCTION -------------------------------------------------- 01
INSTALLATION ---------------------------------------------------- 02
PLUMBING CONNECTION --------------------------------------- 02
FILTER MAINTENANCE ------------------------------------------- 03
FLUSHING OUT THE SEDIMENT CHAMBER ------------------- 03
WARRANTY -------------------------------------------------------- 03
TECHNICAL SPECIFICATION ------------------------------------- 04
DIMENSIONS ------------------------------------------------------ 04
EXPLODED DIAGRAM -------------------------------------------- 05
SAFETY INFORMATION
1. MultiCyclone 70XL is designed to work with water at temperatures greater than 0º C and less than 45ºC. The lter should never be operated outside of these temperatures or damage may occur.
2. The installation should be carried out in accordance to the safety and the specic instructions for each facility.
3. Any modication of the lter requires the prior consent from Waterco. Original replacement parts and accessories authorized by the manufacturer ensure a high level of safety. Waterco assumes no liability for the damage and injuries caused by unauthorised replacement parts and accessories.
4. The user should make sure that the installation is carried out by qualied authorised persons and that these persons have rst carefully read the following instructions.
5. The operating safety of the lter is only guaranteed if the installation and operation instructions are correctly followed.
6. In the event of defective operation or fault, contact Waterco or its nearest authorised service agent.
7. To reduce the risk of injury, do not permit children to use this product unless they are closely upervised at all times.
8. Incorrectly installed equipment may fail, causing severe injury or property damage.
Waterco Multicyclone 70XL
I pg 01
INTRODUCTION
MultiCyclone 70XL is capable of saving water and reducing lter maintenance.
The MultiCyclone 70XL works on the basis of centrifugal water ltration. There are no moving parts to wear and tear, and no lter media to clean or replace.
EXIT PIPE
CYCLONE RH
CYCLONE LH
TOP SHELL
WATER OUTLET 4” PORT
MAINFOLD PLATE
CYCLONE HOLDER
BOTTOM SHELL
WATER INLET 4” PORT
CLEAR PIPE
STAND
DRAIN / FLUSH VALVE
Incoming water is guided by a diverter plate so that it enters multiple hydro cyclones tangentially generating a strong centrifugal effect. This spins the sediment out to the hydro cyclone’s wall and then spirals it down to the sediment chamber, while the cleansed water spirals upwards.
The accumulation of sediment can be visibly monitored through the MultiCyclone 70XL’s clear sight glass. The MultiCyclone 70XL is cleaned by simply opening the purge valve.
MultiCyclone 70XL is ideal as a pre-lter to extend the life of your existing lter.
• Save Water
• Reduce backwash frequency.
Please Note: The MultiCyclone 70XL is designed to filter sediment that is heavier than water; floating debris cannot be filtered out by centrifugal filtration.
INSTALLATION
Be sure to comply with the local plumbing codes. The lter may be plumbed into a drinking water system and would, therefore be subject to whichever local regulations that may apply.
Be sure that all provisions for wastewater disposal meet local, state or national codes. Do not discharge water where it will cause ooding or damage.
If the incoming water pressure is higher than the maximum operating pressure of 250kPa /2.5Bar /36 psi, a Pressure Regulating Valve (PRV) must be installed upstream of the lter inlet.
The PRV should be set to 90% of the maximum operating pressure of the tank.
If the incoming water ow is less than the lter’s minimum ow requirements, the lter’s ltration efciency will be affected, please consult Waterco.
MultiCyclone 70XL Recommended Operational Flow Rates
Minimum ow rate: 36m3/hr (158.5 GPM)
Maximum ow rate: 96 m3/hr (422.7 GPM)
PLUMBING CONNECTION
1. Connect the outlet from your pump to the inlet of the MultiCyclone 70XL.
Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure
solvents are not excessively applied to ttings as this could run into o’rings and create sealing problems. Screw the barrel union on to the inlet of your MultiCyclone 70XL and hand tighten.
2. Connect from the outlet of the MultiCyclone 70XL to the inlet of your filter.
Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure
solvents are not excessively applied to ttings as this could run into o’rings and create sealing problems. Screw the barrel union on to the outlet of your MultiCyclone 70XL and hand tighten.
Waterco Multicyclone 70XL
I pg 03
3. Connect to Waste Line.
Glue the plumbing from the Sediment Purge Valve to your waste line.
4. Turn on pump.
Be sure to check that there are no leaks from the connectors. If required, tighten by hand.
FILTER MAINTENANCE
Filter maintenance determined by the following conditions:
1. The ow rate through the MultiCyclone 70XL is insufcient to meet the demand.
2. The sediment chamber is half lled with sediment.
The accumulation of sediment can be visibly monitored through the MultiCyclone 70XL’s clear sight glass. The MultiCyclone 70XL is cleaned by simply opening the purge valve
FLUSHING OUT THE SEDIMENT CHAMBER
Whilst the water pump is running simply open the sediment purge valve until the sediment has been ushed out. This is visible through the clear sight glass.
Once the sediment has been ushed out, close the sediment purge valve.
WARRANTY
MultiCyclone 70XL is covered by a 2 warranty.
For more information please refer to the Waterco “Warranty Terms & Conditions” booklet. With our on going commitment to quality products and service Waterco Limited reserves the right to alter the product in any manner and at any time without prior warning.
This information is to the best of our knowledge, accurate at the time of printing. Any recommendations or suggestions are made without warranty and without prejudice, since the use of our product is beyond our control.
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00
MultiCyclone 70XL
Total Head Loss Curve
Head Loss (m)
Flow Rate (m3/hr)
TECHNICAL SPECIFICATION
Pressure Rating: 250 kPa / 2.5 bar /36 psi
Minimum Flow Rate: 36m3/hr (158.5 GPM)
Maximum Flow Rate: 108 m3/hr (475.6 GPM)
DIMENSIONS
1359
730
71
654
478,5
740
542,5
Waterco Multicyclone 70XL
I pg 05
EXPLODED DIAGRAM
NO DESCRIPTION QTY
34 Nut M6 (Not Shown) 40 33 Rubber Washer (Not Shown) 1 32 O Ring BS 112 1 31 Air Relief Valve 1 30 Bolt M10 48 29 Bolt M6 40 28 Washer M6 40 27 O Ring BS 009 40 26 O Ring BS 018 70 25 O Ring BS 025 14 24 O Ring BS 392 1 23 O Ring Special 2 22 Washer BH 100mm 2 21 O Ring BS 474 2 20 Washer M10 96 19 Nut M10 48 18 Clear Pipe 50mm 1 17 2 Way Valve 50mm 1 16 Base 1 15 Elbow 50mm 1 14 Half Union 50mm 1 13 Male Valve Socket 1 12 Lower Shell 1 11 Pipe 100mm 1 10 Elbow 90˚ 100mm 1
9 Pipe 100mm 1 8 Bulkhead 100mm 1 7 Cyclone Holder 1 6 Cyclone Cone RH 35 5 Cyclone Cone LH 35 4 Mainfold Plate 1 3 Exit Pipe / Vortex Tube 70 2 Half Union 100mm 2 1 Top Shell 1
Waterco Limited ABN 62 002 070 733
(W99302 / ZZM1449) 07/2013
OFFICES - AUSTRALIA
NSW - SYDNEY (HEAD OFFICE) Tel: +61 2 9898 8600
QLD - BRISBANE Tel: +61 7 3299 9900
VIC/TAS - MELBOURNE Tel: +61 3 9764 1211
WA - PERTH Tel: +61 8 9273 1900
SA/NT - ADELAIDE Tel: +61 8 8244 6000
ACT DISTRIBUTION Tel: +61 2 6280 6476
OFFICES - OVERSEAS
WATERCO (EUROPE) LIMITED Sittingbourne, Kent, UK Tel: +44 (0) 1795 521 733
WATERCO FRANCE Saint Priest, France Tel: +33 4 72 79 33 30
WATERCO (USA) INC Augusta, Georgia, USA Tel: +1 706 793 7291
WATERCO CANADA Longueuil, Quebec, Canada Tel: +1 450 748 1421
WATERCO (NZ) LIMITED Auckland, New Zealand Tel: +64 9 525 7570
WATERCO © LIMITED Guangzhou, China Tel: +86 20 3222 2180
WATERCO (FAR EAST) SDN BHD Selangor, Malaysia Tel: +60 3 6145 6000
PT WATERCO INDONESIA Jakarta, Indonesia Tel: +62 21 4585 1481
WATERCO SINGAPORE INTL PTE LTD Nehsons Building, Singapore Tel: +65 6344 2378
Loading...