Waterco GRAVITY Operating Manual

www.waterco.com
WARNING
!
GRAVITY WATER PURIFIER
Operating Manual
Restoring the Fresh Natural Taste
Gravity Water Purier
This simple unit does not require plumbing or electrical connections.
It is able to signicantly reduce suspended solid, microorganisms, chlorine, organic pesticides and offending tastes/ odours.
How the system should be rst used
A polyethylene container located at the top of the unit is tted with Waterco Ceramic cartridge. Water is poured into the container and is ltered through the ceramic cartridge as it makes its way to the lower chamber. Before the Gravity Water Purier is used, allow approximately 4 litres of water to pass through the system to remove any ne granular activated carbon particles.
These particles are harmless.
CZR canister preparation
Remove the CZR canister from its packaging. Soak the CZR canister in water overnight. Pour water into the canister and then stand it in water that is as deep as the height of the canister. This process will help wet the surface of the CZR and remove trapped air. Screw the CZR canister onto the container. Do not over screw the CZR canister, as the thread may break. The CZR canister, once activated, must not be allowed to dry out.
Important information
1. Gravity Water Purifier should filter approximately 1 Litre per hour. If you are experiencing an unusually slow ow rate; soak the Waterco Ceramic Cartridge in a mug of water for 30 - 45 minutes with the plastic nozzle pointing upwards and above the water level. This procedure will remove trapped air in the cartridge.
2. Ensure that the ltered water is turned over at least once a day. To prevent algae, wipe the Gravity Water Purier’s inner walls once a week.
3. The CZR media should never be allowed to dry out. There are two reasons for this:
a) The bacteriostatic effect ( of the CZR ) will be “ switched off “
if the ltered water is not physically kept in contact with the CZR.
b) The drying process will cause the CZR particles to adhere together.
It will be difcult to pass water through such media as it has become “ blocked up “.
For these reasons, always top up the water in the lter.
Waterco G ravity Water Pu ri fier
How To Clean The Ceramic Cartridge
Low Maintenance
These cartridges require special attention. Please read this section carefully.
1
2
4a
4b
3
The purifying process ensures
Clean, Healthy, Tasty Water.
Step 1
Fill the upper reservoir with ordinary tap water.
Step 2 Ceramic Cartridge
The ceramic layer lters suspended solids and
microorganisms.
(e.g. E.Coli, Giardia & Cryptosporidium).
Step 3 Activated Carbon
The lter’s core of activated carbon adsorbs offending organic chemicals, tastes, odour and
chlorine.
Step 4 CZR Canister (optional)
a) The extra bed of activated carbon extends the
replacement interval of the ceramic cartridge.
b) The CZR electrochemically removes dissolved
metals plus its bacteriostatic properties keep the water in the lower reservoir sanitised.
NOTE : CZR canisters are only supplied with Stoneware Plus and Clearware Plus Water Purifiers and available for separate purchase.
8L - Ceramic Cartridge [58mm(W) x 100mm(H)]
Waterco Ceramic Cartridges are made of micro-porous ceramic material, internally coated with an antibacterial treatment of Silver Nitrate. Within the Waterco Ceramic Cartridge is a Granular Activated Carbon Core.
The ceramic media and
Granular Activated Carbon work together to signicantly reduce :
Suspended Solids, Chlorine, Offending Taste/ Odour, Microorganisms and Organic Pesticides ( e.g. Lindane ).
Ceramic Cartridge
Dome Cartridge
D
o
m
e
C
e
r
a
m
i
c
C
a
r
t
r
i
d
g
e
• Waterco Gravity Water Purier
The Gravity Water Purier is virtually maintenance free.The only component that requires attention is
the ceramic cartridge.
The ceramic cartridge must be cleaned regularly and replaced periodically.
• Cleaning the Ceramic Cartridge
Cleaning simply involves scraping the cartridge under running water. Once the surface is white, the cartridge is ready for use again.
• Replacement Periods
For optimal performance, replace the ceramic cartridges every 4 months. If used in combination with the CZR canister, extend the replacement period to 12 months. For optimal performance, replace the CZR canister every
12 months.
Waterco Limited ABN 62 002 070 733
OFFICES - AUSTRALIA
NSW - Sydney (HEAD OFFICE) Tel : +61 2 9898 8686
VIC/ TAS - Melbourne Tel : +61 3 9764 1211
WA - Perth Tel : +61 8 9273 1900
QLD - Brisbane Tel : +61 7 3299 9900
SA/ NT - Adelaide Tel : +61 8 8244 6000
ACT Distributor Tel : +61 2 6280 6476
OFFICES - OVERSEAS
Waterco USA Augusta, USA Tel : +1 706 793 7291
Waterco Canada St-Hyacinthe, QC, Canada Tel : +1 450 796 1421
Waterco (Europe) Limited Radfield, Kent, UK Tel : +44(0) 1795 521 733
Waterco (NZ) Limited Auckland, New Zealand Tel : +64 9 525 7570
Waterco (GZ) Limited Guangzhou, China Tel : +8620 3222 2180
Waterco (Far East) Sdn. Bhd. Selangor, Malaysia Tel : +60 3 6145 6000
PT Waterco Indonesia Jakarta, Indonesia Tel : +62 21 4585 1481
(7743807) 08/2008