2) DC driven iris lens
The pin configuration of a DC driven iris lens is standardized to EIAJ specifications.
If the DC driven iris lens does not work, check the wiring configuration, referring to the table below.
NOTE: Check the configuration of the iris plug before it is connected to ⑤Auto iris on the WAT-535EX.
After connection, adjust ③Iris level (for auto iris) placed above the iris connector by turning clockwise or
anti-clockwise as shown above.
*The WAT-535EX is compatible with both a Video iris lens and a DC driven iris lens. (Patent pending)
3. Connect ⑦VIDEO OUT on the WAT-535EX with the monitor, using a coaxial cable with 75Ωimpedance, such as an
RG-58/U or an RG-6/U.
IMPORTANT NOTE: Select a monitor with the same transmission mode as the WAT-535EX, there are two versions, NTSC
and PAL. A monitor with more than 700TV lines is recommended.
CAUTION: Do not use a monitor which uses a video signal/power coaxial transmission cable.
4. Insert the power jack of the power adaptor to ⑧POWER IN on the back panel of the WAT-535EX.
NOTE: Confirm that the power adaptor is not connected before insertion of the power jack into ⑧POWER IN.
The optional Watec power adaptor, AD-901 (DC 12V, 250mA) is recommended.
IMPORTANT NOTE: When not using a recommended Watec Power Adaptor:
A. Use a stabilized power adaptor with a voltage range of 12V DC, ±10% and a current capacity of
more than 250mA.
B. Use the additional DC power jack, when the shape or polarity of the power jack of the DC power
adaptor can not be inserted into ⑧POWER IN on the WAT-535EX.
C. Wire the DC Power jack as appropriate. Use the drawing on the right to guide you.
5. Switch on the WAT-535EX, monitor and all other allied equipment.
Remove the power jack of the AD-901, AC adaptor at once whenever the picture does not appear on the monitor.
6. Focusing the lens of the WAT-535EX is achieved by adjusting the lens while looking at the monitor screen.
N.B. In cases when the WAT-535EX can not be focused manually, use the focusing adjustment method set out below.
・Attach the required lens on the WAT-535EX and loosen the three hexagonal focusing adjustment screws.
*Be extremely careful not to drop the lens.
・Set the focus ring to the infinitive position, and while looking at the monitor screen, move the lens forwards or
backwards to focus.
・Tighten ④Hexagonal focusing adjustment screws when focusing is completed.
7. GAIN CONTROL: Turn according to your requirements.
The optimal picture can be obtained under various environments when GAIN CONTROL on the back panel is turned
clockwise or anti-clockwise as shown below on the left;
・Gain corresponding to the brightness of an object is automatically adjusted in a range between 5dB - 32dB when GAIN
CONTROL is locked in the AGC position.
*When AGC is set at AGC LO, brightness of an object is automatically adjusted to a range between 5dB - 20dB.
・When using the MGC function (after unlocking GAIN CONTROL clockwise ), the gain can be manually fixed in a range
between 5 - 32dB.
・When a high S/N is required in low fluctuating brightness situations, lower the gain by
turning GAIN CONTROL anti-clockwise so as to be able to obtain the best optical
picture, then adjust the iris function on the lens to the lighting conditions.
・When there is a dark environment, in low fluctuating brightness situations, increase
the gain by turning GAIN CONTROL clockwise.
・When a wide depth of field is required, first turn the lens iris towards the closed
position, then adjust the gain using GAIN CONTROL.
8. Select any required shutter speed by the Sutter speed selector to one of its 9 positions when required.
*When an object with high brightness is focussed upon (especially on shutter operation), smearing phenomena may appear on
the monitor. This does not mean damage has occurred to the WAT-535EX.
9. Select any required functions by setting four Function Switches at upper or lower positions.
Note: How to dismount the lower housing cover of the WAT-535EX
・Switch off the power.
・Remove the four fixing screws from the housing cover.
・Slowly side the housing cover away downwards from the main unit.
・For replacement, repeat the above procedure in reverse.
CAUTION: Change any required switch setting firmly to avoid any operational or functional instability of the camera.
How to set
Function SW:
・For producing the best possible results, adjust the switches to meet your requirements while taking
into consideration the use of the WAT-535EX, the environment and the desired picture quality.
10. When external synchronization is required, insert the synchronization signal jack into the ⑨SYNC IN, BNC terminal.
*The signal required for input is C.SYNC or C. Video using 0.2 to 4Vp-p.
*The input resistance of the WAT-535EX is 10K Ω, but when 75Ω is required, the external synchronization signal
cable must be terminated to earth. In this case, the input voltage is the same as the above.
*The WAT-535EX is set at internal synchronization. When a synchronized signal is received by the camera it will
adjust automatically to external synchronization.
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
Important:
The camera mentioned above does not comply with this regulation, if it is modified at your disposal.
Design and specifications are subject to change without notice.
Watec is not responsible for any inconvenience or the attendant damages to the video, audio and monitoring recording
equipment, caused by misuse, mis-operation or improper wiring of our equipment.
If for any reason the WAT-535EX does not work properly, or if you have any questions regarding installation or operation,
please contact the distributor or dealer from which it was purchased.
Watec Co., Ltd.
Address: 254-2, Nihonkoku, Daihoji, Tsuruoka-Shi, Yamagata-Ken, 997-0017 Japan
Phone: +81-235-25-7164 Fax: +81-235-23-4409
E-mail: info@watec.net
SPECIFICATIONS:
Model No.
CCD
Number of total pixels
Number of effective pixels
Unit cell size
Scanning system
Sync. System
External sync. System
External sync. Signal
Video output
Resolution
Minimum illumination
Gamma characteristic
AGC ON
OFF
Back light AGC
compensation EI
S/N ratio
Auto iris
AE EI
ES
FL
OFF
Lens mount
Power supply
Current
Storage temperature
Operating temperature
Dimensions
Weight
WAT-535EX (EIA) WAT-535EX (CCIR)
1/3 inch Interline transfer CCD image sensor
811 (H)×508 (V) 795 (H)×596 (V)
768 (H)×494 (V) 752 (H)×582 (V)
6.35um (H)×7.40um (V) 6.50um (H)×6.25um (V)
2:1 interlace
Internal/External
C.Sync/C.Video
Signal: 0.2〜4.0Vp-p
Composite Video, 1Vp-p, 75ΩUnbalanced
550TV lines (center)
0.003 lx F1.4 (AGC 32dB)
0.45/OFF
HI: 5〜32dB (AGC) LO: 5〜20dB (AGC)
5〜32dB (Manual)
ON/OFF
ON/OFF
50dB (GAIN 5dB)
DC/VIDEO
1/60sec. 〜1/100000sec. 1/50sec. 〜1/100000sec.
1/250sec., 1/500sec., 1/1000sec., 1/2000sec., 1/5000sec.,1/10000sec.,
1/100000sec.
1/100sec. 1/120sec.
1/60sec. 1/50sec.
CS-mount
DC+10.8〜13.2V (12V±10%)
Max. 150mA
−10℃〜+40℃
−30℃〜+70℃
44mm (W)×43.5mm (H)×53mm (D)
Approx. 130g
Switch
1:ΓON/OFF
2:AGC HI/LO
3:AGC B/L
4:EI B/L
Setting
ON
OFF
HI
LO
ON
OFF
ON
OFF
Upon shipment
CAUTION: Be careful not to create a short circuit during the wiring process. It may cause damage or even fire to
the WAT-535EX and power adaptor, if the above care and attention is not adhered to when the power
supply is resumed.
Pin No.
①
②
③
④
DC driven iris lens arrangement (EIAJ)
Control − (DUMP−)
Control + (DUMP+)
Drive + (DRIVE+)
Drive + (DRIVE−)
Effect (Example)
・Applicable to general surveillance monitoring system
・When gamma correction function is harmful when storing or
downloading pictures onto a computer.
・When gamma correction is not required.
・When minimum illumination is more important than the S/N ratio.
Surveillance in low light environments. Useful in the AGC
position using
GAIN CONTROL on the back panel.
・When a clear picture is required in standard lighting conditions.
・When the object monitored on the screen disappears due to being
illuminated brightly from behind. (useful in the AGC position
by using
GAIN CONTROL on the back panel)
・Normally used in this position.
・Effective at EI position by operation of 11 (EI) rotary switch when
the object monitored on the screen appears black due to being
illuminated from behind.
・Normally used in this position.