WAA-232-485 Converter Operation Manual
3 5 1 F E R R I E R S T R E E T • M AR K H A M , O N • L 3 R 5 Z 2
P HO N E : 4 1 6 - 410- 6 8 6 5 / TO LL F RE E : 1 -8 6 6 - 3 3 1 - 3 3 4 1 • F A X : 9 0 5 - 7 5 2- 01 86
W W W . W A T C H N E T A CC E S S . C O M / IN F O @ W A T C H N E T D V R . C O M
WAA-232-485 Converter
Operation Manual v1.0

WAA-232-485 Converter Operation Manual
3 5 1 F E R R I E R S T R E E T • M AR KH AM , O N • L 3R 5 Z 2
P HO N E : 4 1 6 - 410- 6 8 6 5 / TO LL F RE E : 1 -8 6 6 - 3 3 1 - 3 3 4 1 • F A X : 9 0 5 - 7 5 2- 01 86
W W W . W A T C H N E T A CC E S S . C O M / IN F O @ W A T C H N E T D V R . C O M
System Features
1. WAA-232-485 is converts the RS485 data format to RS232. It is essential for
exchanging data between the PC and the controllers.
2. The WAA-232-485 is powered up through a USB port, for easy connection.
3. 1 set of WAA-232-485 can be used to support 32 -128 controllers networked at
the same time.
Note: Do not use the same source of power supply for the WAA-232-485 and the
electrical door lock to avoid electrical sparkle interference.
Technical Specifications
Speed: 0-115200bps
Transmitting range: 1200m.
Support 1 to 127 nodes.
Power: 7-12AC/DC
Operating Current: 200mA
Operating temperature: -40℃ ~ +70℃.
Humidity: 5%~95%
Size: 63mm x 93mm x 20mm
3 LEDs to display the status.
Thunder Protection.
Pin definitions

WAA-232-485 Converter Operation Manual
3 5 1 F E R R I E R S T R E E T • M AR KH AM , O N • L 3R 5 Z 2
P HO N E : 4 1 6 - 410- 6 8 6 5 / TO LL F RE E : 1 -8 6 6 - 3 3 1 - 3 3 4 1 • F A X : 9 0 5 - 7 5 2- 01 86
W W W . W A T C H N E T A CC E S S . C O M / IN F O @ W A T C H N E T D V R . C O M
Switch setting and baud rate regulation
A) DIP 1-3: the switches 1, 2, 3 are used to set the baud rate. The baud rate is set
based on the controller that is connected to the converter WAA-232-485.
WAC-XDY controllers support 9,600 bps only.
B) DIP 4: It is used to set data bit when transmitting.
Standard 11 bits transmitting mode (8,1,1,n modes)
For WAC-XDY controllers the default is DIP1=ON, DIP2=OFF, DIP3=ON, DIP4=ON.
Connection method
RS-485 connection: