WatchGuard AP327X quick start Guide

Page 1
WatchGuard® AP
AP327X
HW Model: O-105E
Quick Start Guide
WatchGuard® Technologies, Inc.
Page 2
Pole Mount Accessories
Wall m oun t
Dri ll loca tion Ins ert fou r ancho rs
Ground Wire
ACTIVATE YOUR APCONTENTS
1
GO TO:
watchguard.com/activate
English
Pole mount clamps
Ground Wire Ground Wire Screw
Wall Mount Accessories
50.00 m m
84.00 m m
Wall mount stencil Wall mount
Optional Accessories
Antenna Options
WG9004 Dual-Band Omni Antennas (5/7 dBi)
Power Options
WG8599 (US) WatchGuard 802.3at PoE+ Injector with AC cord (US)
WG8600 (EU) WatchGuard 802.3at PoE+ Injector with AC cord (EU)
WG8601 (UK) WatchGuard 802.3at PoE+ Injector with AC cord (UK)
WG8602 (AU) WatchGuard 802.3at PoE+ Injector with AC cord (AU)
4x
Anchors
4x
Anchor Screws
4x
Wall Mount
Screws
AP327X
Model: O-105E
Input:PoE (802.3at): 48V , 400mA
SN: 37AP0007A-XXXX
Eth. MAC: 00:90:7F:13:02:DF
2 3
Page 3
Wall m oun t
Po l e moun t
1 2 3
2
MOUNT YOUR AP
Pole Mount
Wall Mount
1 2 3
1
1 32
84.00 m m
Dri ll loca tion Ins ert fou r ancho rs
50.00 m m
4
4
2
5
5 6
3
6
4 5
Page 4
Ground Wire
To protect your outdoor AP from electrical events, we recommend you ground the AP with the included ground wire based on your local regulations.
Um Ihren AP im Außenbereich vor elektrischen Problemen zu schützen, empfehlen wir, den AP gemäß den lokalen
Vorschriften mit dem bereitgestellten Erdungskabel zu erden.
Para proteger su PA exterior de eventos eléctricos, recomendamos que lo conecte a tierra con el cable de conexión a
tierra incluido, según sus regulaciones locales.
A m de proteger seu AP para ambientes externos contra eventos elétricos, recomendamos aterrá-lo com o o de ater-
ramento incluído conforme a regulamentação local.
Per proteggere l’AP da fenomeni elettrici, si raccomanda di collegarlo a terra con l’apposito cavo incluso nella confezi-
one ai sensi delle normative locali.
Pour protéger votre point d’accès extérieur des événements électriques, nous vous recommandons de le raccorder à la
terre à l’aide du câble de terre fourni, conformément aux réglementations locales.
 為了保護室外AP不受電氣事件影響,建議您根據當地法規使用內含的接地線對AP進行接地。
야외AP를전기사고발생위험으로부터보호하려면지역별규정에따라AP를동봉된접지와이어로접지하는 것이좋습니다.
 屋外用APを落雷や感電などの事故から守るために、地元の規制に従って、付属の接地線を使用してAPの接
地を行うことをお勧めします。
 为了保护您的户外AP免受电气活动的影响,我们建议您根据当地的法规,使用随附的地线将AP接地。
ATTACH ANTENNAS (Sold separately)
3
6 7
Page 5
4
CONNECT YOUR AP
PoE+ power (injector or switch)
OR
LAN1 (PoE)
This device supports PoE+ (802.3at) only. The use of PoE (802.3af) power may result in limited functionality and device instability.
Dieses Gerät unterstützt nur PoE+ (802.3at). Die Verwendung von PoE (802.3af) kann in eingeschränkter Funk­tionalität und Geräteinstabilität resultieren.
Este dispositivo solo admite PoE+ (802.3at). El uso de PoE (802.3af) puede generar una funcionalidad limitada e inestabilidad del dispositivo.
O dispositivo é compatível apenas com PoE+ (802.3at). O uso de alimentação PoE (802.3af) pode limitar a funcio­nalidade e deixar o dispositivo instável.
Questo dispositivo supporta solo lo standard PoE+ (802.3at). L’alimentazione tramite PoE (802.3af) può limitare la funzionalità del dispositivo e renderlo instabile.
Cet appareil est compatible avec la technologie PoE+ (norme 802.3at) uniquement. L’utilisation de lalimentation PoE (norme 802.3af) peut entraîner une limitation des fonctionnalités et une instabilité de lappareil.
此裝置僅支援PoE+(802.3at)標準。使用PoE(802.3af)電源可能導致功能受限和裝置不穩定。
이장치는PoE+(802.3at)만지원합니다.PoE(802.3af)전원을사용하면기능이제한되고장치안정성을저 해할수있습니다.
本装置はPoE+(802.3at)のみに対応しています。PoE(802.3af)で給電を行うと、機能および装置の 設置性が制限される可能性があります。
此设备仅支持PoE+(802.3at)。使用PoE(802.3af)电源可能会导致功能受限并且设备不稳定。
Ethernet Cable Installation
8 9
Page 6
CHECK AP STATUS
5
Power
O: Powered o
Green: Powered on
2.4 GHz and 5 GHz
O: Powered o
Green: Wireless radio on, no clients connected Flashing: Wireless radio activity
LAN1 (PoE) and LAN2
O: No Ethernet Link
Green: Connected to network Flashing: Network activity
CONFIGURE AP
6
GO TO:
watchguard.com/start
Manage APs with
WatchGuard Wi-Fi Cloud
Manage APs with your
WatchGuard Firebox
(Fireware v12.5 or higher)
10 11
Page 7
Certications
NOTICES:
All WatchGuard products are designed and tested to meet strict safety requirements. These requirements include product safety approvals and other global compliance standards. Please read these instructions carefully before operating the product, and refer to them as needed to ensure the continued safe operation of your product.
Additional information, including a full list of safety approvals, global compliance standards, and certications can be found in the Hardware Guide for this device located on the WatchGuard website:
https://www.watchguard.com/wgrd-help/documentation/hardware-guides
Europe - EU Declaration of Conformity (Wireless)
This device complies with the essential requirements of the RED Directive 2014/53/EU. The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the RED Directive 2014/53/EU:
EN 60950-1:2006+A11+A1+A12+A2:2013
Safety of Information Technology Equipment (ITE).
EN 55024:2010
Immunity for Information Technology Equipment (ITE).
EN 55032:2015/AC/2016
Electromagnetic compatibility of multimedia equipment - Emission requirements.
EN 62311:2008
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic elds (0 Hz - 300 GHz).
EN 300 328 V2.1.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband transmission systems; Data transmission equipment operating in the 2.4GHz ISM band and using wide band modulation techniques; Harmonized EN covering the essential requirements of article 3.2 of the RED Directive.
EN 301 893 V2.1.1
Broadband Radio Access Networks (BRAN); 5GHz high performance RLAN; Harmonized EN covering the essential requirements of article 3.2 of the RED Directive.
EN 301 489-1 V2.1.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements.
EN 301 489-17 V3.1.1
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specic conditions for Broadband Data Transmission Systems.
This device is a 5GHz wideband transmission system (transceiver), intended for use in all EU member states and EFTA countries, except in France and Italy where restrictive use applies. In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and/or for supplying public access to telecommunications and/or network services.
This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 - 2483.5 MHz. For detailed informa-tion the end-user should contact the national spectrum authority in France.
EN 61000-3-2:2014
Limits for harmonic current emissions.
EN 61000-3-3:2013
Limitation of voltage changes, voltage uctuations and icker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection.
12 13
Page 8
Frequency range (MHz)
Max. Transmit Power (W)
Bluetooth
0.00794
WLAN Wi-FI 802.11x; 2, 4 GHz
0.09977
WLAN Wi-FI 802.11x; 5 GHz
0.19907
Certications
ANATEL WARNING
Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados.
Este produto não é apropriado para uso em ambientes domésticos, pois poderá causar interferências eletromagnéticas que obrigam o usuário a tomar medidas necessárias para minimizar estas interferências.
WatchGuard Technologies Inc. hereby declares that the product(s) listed below conform to the
Product (s):
802.11 a/n/ac + b/g/n Access Point, O-105E
EU Directive(s):
Low Voltage (2014/35/EU) Electromagnetic Compatibility (2014/30/EU) Energy-related Products (2009/125/EC) RoHS (2002/95/EC) WEEE Directive 2002/96/EC The Radio Equipment Directive (2014/53/EU)
Common Standard(s):
EN 60950-1:2006+A11+A1+A12+A2:2013 Safety for ITE EN 55024:2010 EN 55032:2012/AC:2013 EN 62311:2008 EN 61000-3-2:2014 Harmonics EN 61000-3-3:2013 Flicker
Wireless Standard(s):
EN 301 489-01 v2.1.1 EMC and Radio Spectrum Matters EN 301 489-17 v3.1.1 EMC and Radio Spectrum Matters EN 300 328 v2.1.1 Radio Spectrum Matters
EN 301 893 v2.1.1 Broadband Radio Access Networks
This device complies with Directive 2014/53/EU issued by the Commission of the European Community.
Manufacturer / Hersteller: WatchGuard Technologies
Equipment / Funk anlage: 802.11 a/n/ac + b/g/n Access Point Type Designation / Typenbezeichnung: O-105E Specifications / Technische Daten: 802.11a,b,g,n,ac (2.4Ghz & 5GHz)
Intended Purpose / Verwendungszweck: Outdoor Access Point Equipment Class / Betriebsmittel der Klasse: Class II
Operating temperature -40° C to +65° C
The above device complies with the essential requirements and other relevant provisions to Directive 2014/53/EU when used for its intended purpose. This equipment may be operated in the USA, Canada, & Europe Union. Warning! This is a Class B product. In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
Restrictions: France (i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; (ii) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5 250-5 350 MHz et 5 650-5 850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL.
Die oben genannten Gerät entspricht den grundlegenden Anforderungen und anderen relevanten Bestimmungen der Richtlinie 2014/53/EU, wenn für den vorgesehenen Zweck verwendet werden. Dieses Gerät ist für die Verwendung in den USA, Kanada, and Europäische Union.
Warnung! Dies ist eine Einrichtung der Klasse B. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen durchzuführen
Einschränkungen: Frankreich(i)-Geräte, die im Band 5150-5250 MHz ist nur für den Innenbereich, um das Risi ko von Störungen des mobilen Satelliten-Systeme, die die gleichen Kanäle (ii) Darüber hinaus reduzieren vorbehalten, sollten Benut zer auch darauf hingewiesen werden, dass die Nutzer von Hochleistungs-Radare bezeichnet werden primäre Benutzer (dh d. sie haben Priorität) der Bänder 5 250-5 350 MHz und 5 650-5 850 MHz und dass diese Radargeräte können Störungen und / oder Schäden an LE-LAN­Geräten verursachen.
Declaration of Conformity
European Union directives and standards identified in this declaration.
Immunity for ITE
505 5th Ave S. Suite 500, Seattle, WA 98104 USA Radio
Signature
Full Name: Laurence Huang Position:
Manufacturing Program Manager Date: June 12, 2019
14 15
Page 9
WATCHGUARD TECHNICAL SUPPORT
1.877.232.3531 (U.S. and Canada)
+1.206.613.0456 (all other countries)
www.watchguard.com/support
ADDRESS: 505 Fifth Avenue South, Suite 500, Seattle, WA 98104 WEB: www.watchguard.com • U.S. SALES: 1.800.734.9905 • INTERNATIONAL SALES: +1.206.613.0895
© 2019 WatchGuard Technologies, Inc. All rights reserved. WatchGuard, the WatchGuard Logo, Fireware, and LiveSecurity are registered trademarks of WatchGuard Technologies, Inc. in the United States and/or other countries. All other trademarks and tradenames are the property of their respective owners. 352-4327-001 Rev B 100919
16
Loading...