1. Insert an Ethernet cable into the Ethernet interface on the WatchGuard AP device.
2. Connect the other end of the Ethernet cable to your network.
3. Connect the power adapter to the DC power connector on the WatchGuard AP device. If you
use a PoE adapter, make sure that the Ethernet cable is connected to the correct port on the PoE
adapter.
The device powers on. The Power/Status light ashes amber while the device boots up and then changes
to steady green when the device is ready.
Assign an IP Address to the WatchGuard AP Device
There are two ways the WatchGuard AP device can get an IP address:
• Automatic IP Address Conguration by DHCP - When rst powered on, the WatchGuard AP
device automatically requests an IP address from a DHCP server on your network.
• Manual IP Address Conguration - If you do not use DHCP on your network, you must directly
connect to the WatchGuard AP device to assign a static IP address.
To set the IP address on your WatchGuard AP device:
• Connect an Ethernet cable from the AP device to your computer.
• Congure your computer to use these settings: IP Address: 192.168.1.2, Subnet mask:
255.255.255.0, Gateway: 192.168.1.1.
• Open a web browser and type https://192.168.1.1.
• To log in to the WatchGuard AP web UI, type the default password: wgwap.
• Set the IP address of the AP device to an IP address on the same network as your XTM device.
Pair the AP Device with a WatchGuard XTM Device
You can now pair the WatchGuard AP device with an XTM device.
1. Use Policy Manager or the Fireware XTM Web UI to edit the XTM device conguration.
2. Select Network > Gateway Wireless Controller.
3. Enable the Gateway Wireless Controller, and save the conguration to the XTM device.
4. In the Gateway Wireless Controller conguration, on the Access Points tab, click Refresh to
discover the AP device.
5. Select the unpaired Access Point and click Pair.
6. In the Pairing Passphrase dialog box, type the passphrase of the AP device. The default
passphrase is wgwap.
For detailed information about WatchGuard AP pairing, management, and conguration with your
XTM device, see the WatchGuard AP Device Setup section of the Fireware XTM Web UI or WSM Help at
1. Connectez un câble Ethernet à l'interface Ethernet du périphérique WatchGuard AP.
2. Connectez l'autre extrémité du câble Ethernet à votre réseau.
3. Connectez l'adaptateur secteur au connecteur d'alimentation en courant continu du périphérique
WatchGuard AP. Si vous utilisez un adaptateur PoE (Power-over-Ethernet), assurez-vous que le
câble Ethernet est connecté au bon port de l'adaptateur PoE.
Le périphérique se met sous tension. Le voyant de Power/Status clignote en couleur ambre lorsque
l'appareil s'allume et devient vert lorsque l'appareil est prêt à être utilisé.
Attribuer une adresse IP au périphérique WatchGuard AP
Le périphérique peut obtenir une adresse IP de deux diérentes façons:
• Conguration automatique de l'adresse IP grâce au protocole DHCP - Lorsque vous l'allumez
pour la première fois, le périphérique WatchGuard AP demande automatiquement une adresse IP
au serveur DHCP de votre réseau.
• Conguration manuelle de l'adresse IP - Si vous n'utilisez pas le protocole DHCP sur votre
réseau, vous devez vous connecter sur le périphérique WatchGuard AP pour lui attribuer une
adresse IP statique.
Pour dénir une adresse IP sur votre périphérique WatchGuard AP:
• Connectez un câble Ethernet reliant le périphérique AP et votre ordinateur.
• Congurez votre ordinateur avec les paramètres suivants: adresse IP: 192.168.1.2, masque
de sous-réseau: 255.255.255.0, passerelle: 192.168.1.1.
• Ouvrez votre navigateur Web et saisissez https://192.168.1.1.
• Pour vous connecter à l'interface Web du périphérique WatchGuard AP, saisissez le mot de
passe par défaut: wgwap.
• Dénissez l'adresse IP du périphérique AP sur une adresse IP se trouvant sur le même réseau
que votre périphérique XTM.
Associer le périphérique AP à un périphérique WatchGuard XTM
Vous pouvez maintenant associer le périphérique WatchGuard AP à un périphérique XTM.
1. Utilisez Policy Manager ou l'interface Web Fireware XTM pour modier la conguration du
périphérique XTM.
3. Activez le Gateway Wireless Controller et enregistrez la conguration sur le périphérique XTM.
4. Dans la conguration Gateway Wireless Controller, cliquez sur Refresh dans l'onglet Access Points
pour acher le périphérique AP.
5. Sélectionnez le point d'accès non apparié et cliquez sur Pair.
6. Dans la boîte de dialogue Pairing Passphrase, saisissez le mot de passe du périphérique AP. Le
mot de passe par défaut est wgwap.
Pour obtenir des informations détaillées sur l'association, la gestion et la conguration du périphérique
WatchGuard AP avec votre périphérique XTM, consultez la section d'installation du périphérique
WatchGuard AP de l'interface Web Fireware XTM ou l'aide WSM en ligne accessible à l'adresse
1. Stecken Sie ein Ethernet-Kabel in die Ethernet-Schnittstelle des WatchGuardAP-Geräts.
2. Schließen Sie das andere Ende des Ethernet-Kabels an das Netzwerk an.
3. Schließen Sie das Netzteil an den Gleichstromanschluss des WatchGuardAP-Geräts an. Falls Sie
einen PoE-Adapter verwenden, stellen Sie sicher, dass das Ethernet-Kabel mit dem richtigen
Anschluss dieses Adapters verbunden ist.
Das Gerät wird eingeschaltet. Das Licht Power/Status blinkt in Gelb, während das Gerät hochgefahren wird,
und leuchtet anschließend in Grün, wenn das Gerät betriebsbereit ist.
Zuweisen einer IP-Adresse für das WatchGuardAP-Gerät
Dem WatchGuardAP-Gerät kann eine IP-Adresse auf zweierlei Weise zugewiesen werden:
• Automatische IP-Adressenkonguration durch DHCP: Wenn das WatchGuardAP-Gerät zum
ersten Mal eingeschaltet wird, fordert es automatisch von einem DHCP-Server des Netzwerks eine
IP-Adresse an.
• Manuelle IP-Adressenkonguration: Wenn Sie für das Netzwerk kein DHCP verwenden, muss
eine direkte Verbindung zum WatchGuardAP-Gerät hergestellt werden, damit eine statische
IP-Adresse zugewiesen werden kann.
So richten Sie die IP-Adresse auf dem WatchGuardAP-Gerät ein:
• Verbinden Sie das AP-Gerät und den Computer mit einem Ethernet-Kabel.
• Kongurieren Sie den Computer so, dass folgende Einstellungen verwendet werden:
• Önen Sie einen Webbrowser, und geben Sie https://192.168.1.1 ein.
• Geben Sie zum Anmelden auf der Webbenutzeroberäche von WatchGuardAP das
Standardkennwort wgwap ein.
• Verwenden Sie als IP-Adresse des AP-Geräts eine IP-Adresse, die sich im selben Netzwerk
bendet wie das XTM-Gerät.
Koppeln des AP-Geräts mit einem WatchGuardXTM-Gerät
Sie können jetzt das WatchGuardAP-Gerät mit einem XTM-Gerät koppeln.
1. Verwenden Sie den PolicyManager oder die Webbenutzeroberäche von FirewareXTM zum
Bearbeiten der XTM-Gerätekonguration.
2. Wählen Sie Network > Gateway Wireless Controller aus.
3. Aktivieren Sie den GatewayWirelessController, und speichern Sie die Konguration auf dem
XTM-Gerät.
4. Klicken Sie in der GatewayWirelessController-Konguration auf der Registerkarte Access Points
auf Refresh, damit das AP-Gerät erkannt wird.
5. Wählen Sie den nicht gekoppelten Zugrispunkt aus, und klicken Sie auf Pair.
6. Geben Sie im Dialogfeld Pairing Passphrase die Passphrase des AP-Geräts ein. Die Standard-
Passphrase lautet wgwap.
Genauere Informationen über die Kopplung, Verwaltung und Konguration von WatchGuardAP nden Sie
auf der Webbenutzeroberäche von FirewareXTM im Abschnitt über die Einrichtung von WatchGuard
AP-Geräten oder in der WSM-Hilfe unter http:www.watchguard.com/help/documentation/xtm.asp.
56
Page 5
Italiano
Connessione del dispositivo WatchGuard AP
1. Inserire un cavo Ethernet nel connettore Ethernet sul dispositivo WatchGuard AP.
2. Collegare l’altra estremità del cavo Ethernet alla rete.
3. Collegare l’adattatore di corrente al connettore di alimentazione CC sul dispositivo
WatchGuard AP. Se si usa un adattatore PoE, accertarsi che il cavo Ethernet sia collegato alla porta
giusta sull’adattatore PoE.
Il dispositivo si accende. La spia di Power/Status lampeggia in ambra mentre il dispositivo si avvia e quindi
diventa verde a luce ssa quando il dispositivo è pronto.
Assegnazione di un indirizzo IP al dispositivo WatchGuard AP
Il dispositivo WatchGuard AP può ottenere un indirizzo IP secondo l’uno o l’altro dei seguenti modi:
• Congurazione automatica dell’indirizzo IP tramite DHCP - Quando si accende, il dispositivo
WatchGuard AP richiede automaticamente un indirizzo IP da un server DHCP della rete.
• Congurazione manuale dell’indirizzo IP - Se non si usa DHCP sulla rete, occorre collegarsi
direttamente al dispositivo WatchGuard AP per assegnare un indirizzo IP statico.
Per impostare l’indirizzo IP sul dispositivo WatchGuard AP:
• Collegare un cavo Ethernet dal dispositivo AP al computer.
• Congurare il computer con le seguenti impostazioni: Indirizzo IP: 192.168.1.2, subnet mask:
255.255.255.0, gateway: 192.168.1.1.
• Aprire un browser e digitare https://192.168.1.1.
• Per accedere all’interfaccia utente web del dispositivo WatchGuard AP, digitare la password
predenita: wgwap.
• Impostare l’indirizzo IP del dispositivo AP in modo che corrisponda a un indirizzo IP sulla
stessa rete del dispositivo XTM.
Associazione del dispositivo AP con un dispositivo WatchGuard XTM
A questo punto si può associare il dispositivo WatchGuard AP a un dispositivo XTM.
1. Usare Policy Manager o l’interfaccia utente web di Fireware XTM per modicare la congurazione
del dispositivo XTM.
3. Abilitare il Gateway Wireless Controller e salvare la congurazione nel dispositivo XTM.
4. Nella congurazione del Gateway Wireless Controller, sulla scheda Access Points, fare clic su
Refresh per rilevare il dispositivo AP.
5. Selezionare l’Access Point non associato e fare clic su Pair.
6. Nella nestra di dialogo Pairing Passphrase, digitare la password del dispositivo AP. La password
predenita è wgwap.
Per informazioni dettagliate sull’associazione del dispositivo WatchGuard AP, sulla gestione, e sulla
congurazione con il dispositivo XTM, consultare la sezione WatchGuard AP Device Setup dell’interfaccia
utente web di Fireware XTM o la guida in linea WSM su: http:www.watchguard.com/help/documentation/
xtm.asp.
78
Page 6
Español
Conecte el dispositivo WatchGuard AP
1. Conecte un cable Ethernet a la interfaz Ethernet del dispositivo WatchGuard AP.
2. Conecte el otro extremo del cable Ethernet a su red.
3. Conecte el adaptador de energía al conector de energía CC del dispositivo WatchGuard AP. Si
utiliza un adaptador PoE, asegúrese de que el cable Ethernet esté conectado al puerto correcto
del adaptador PoE.
Se enciende el dispositivo. La luz indicadora de Power/Status se enciende de forma intermitente con color
ámbar mientras el dispositivo se está iniciando y luego queda ja de color verde cuando el dispositivo
está listo.
Asigne una dirección IP al dispositivo WatchGuard AP
Hay dos formas de asignar una dirección IP al dispositivo WatchGuard AP:
• Conguración automática de dirección IP por DHCP: la primera vez que se enciende el dispositivo
WatchGuard AP, solicita automáticamente una dirección IP a un servidor DHCP de su red.
• Conguración manual de dirección IP: si no utiliza DHCP en su red, debe conectarse
directamente con el dispositivo WatchGuard AP para asignarle una dirección IP estática.
Para congurar la dirección IP de su dispositivo WatchGuard AP:
• Conecte un cable Ethernet del dispositivo AP a su computadora.
• Congure su computadora para que utilice estos parámetros: Dirección IP: 192.168.1.2,
Máscara de subred: 255.255.255.0, Puerta de enlace: 192.168.1.1.
• Abra un explorador web e ingrese https://192.168.1.1.
• Para iniciar sesión en la interfaz web de WatchGuard AP, escriba la contraseña
predeterminada: wgwap.
• Congure la dirección IP del dispositivo AP con los datos de una dirección IP de la misma red
que su dispositivo XTM.
Congure como pares el dispositivo AP y un dispositivo WatchGuard XTM
Ahora puede establecer como pares el dispositivo WatchGuard AP y un dispositivo XTM.
1. Use la función Policy Manager o la interfaz web de Fireware XTM para editar la conguración del
dispositivo de XTM.
3. Active el controlador inalámbrico de puerta de enlace y guarde la conguración en el
dispositivo XTM.
4. En la conguración del controlador inalámbrico de puerta de enlace, en la pestaña Access Points,
haga clic en Refresh para descubrir el dispositivo AP.
5. Seleccione el punto de acceso sin par y haga clic en Pair.
6. En el cuadro de diálogo Pairing Passphrase, escriba la contraseña del dispositivo AP.
La contraseña predeterminada es wgwap.
Para obtener información detallada sobre el establecimiento de pares con WatchGuard AP, su
administración y su conguración con su dispositivo XTM, consulte la sección WatchGuard AP Device Setup
(Conguración de dispositivos WatchGuard AP) de la interfaz web de Fireware XTM o la ayuda de WSM en
1. Insira um cabo Ethernet na interface Ethernet no dispositivo WatchGuard AP.
2. Conecte a outra extremidade do cabo Ethernet à sua rede.
3. Conecte o adaptador de corrente ao conector de alimentação CC no dispositivo WatchGuard AP.
Se você usa adaptador PoE, certique-se de que o cabo Ethernet está conectado à porta correta
no adaptador PoE.
O dispositivo será ligado. A luz de Power/Status pisca em âmbar enquanto o dispositivo inicia e, em
seguida, ca constantemente verde quando o dispositivo está pronto.
Designar uma endereço IP ao dispositivo WatchGuard AP
Há duas maneiras pelas quais o dispositivo WatchGuard AP pode obter um endereço IP:
• Conguração automática de endereço IP por DHCP - Ao ser ligado pela primeira vez, o dispositivo
WatchGuard AP solicita automaticamente um endereço IP de um servidor DHCP na sua rede.
• Conguração manual de endereço IP - Se DHCP não é usado na sua rede, é necessário conectar
diretamente o dispositivo WatchGuard AP para designar um endereço IP estático.
Para congurar o endereço IP no seu dispositivo WatchGuard AP:
• Conecte um cabo Ethernet de um dispositivo AP ao seu computador.
• Congure seu computador para usar as seguintes denições: Endereço IP: 192.168.1.2,
Máscara de sub-rede: 255.255.255.0, Gateway: 192.168.1.1.
• Abra um navegador da web e digite https://192.168.1.1.
• Para fazer logon na interface de usuário na web do WatchGuard AP, digite a senha
padrão: wgwap.
• Estabeleça o endereço IP do dispositivo AP para um endereço IP na mesma rede do seu
dispositivo XTM.
Parear o dispositivo AP com um dispositivo WatchGuard XTM
Agora você pode parear um dispositivo WatchGuard AP com um dispositivo XTM.
1. Use o Policy Manager ou a interface de usuário na web do Fireware XTM para editar as
congurações do dispositivo XTM.
3. Habilite o Controlador sem o de Gateway e salve as congurações no dispositivo XTM.
4. Nas congurações do Controlador sem o de Gateway, na guia Access Points, clique em Refresh
para descobrir o dispositivo AP.
5. Selecione o Ponto de acesso não pareado e clique em Pair.
6. Na caixa de diálogo Pairing Passphrase, digite a frase secreta do dispositivo AP. A frase secreta
padrão é wgwap.
Para informações detalhadas sobre pareamento, gerenciamento e conguração do WatchGuard AP com
o seu dispositivo XTM, consulte a seção de Conguração de dispositivo WatchGuard AP da interface
de usuário da web do Fireware XTM ou a Ajuda do WSM no site http:www.watchguard.com/help/
documentation/xtm.asp.
1112
Page 8
WatchGuard AP デバ イスの 接 続
日本語
AP デバ イスと WatchGuard デバ イスの ペアリング
1. イーサネットケーブルを WatchGuard AP デバイスのイーサネット インターフェイスに 挿 入します。
4. 在閘道無線控制器組態的•Access Points 標籤上,按一下•Refresh 探索 AP 裝置。
5. 選取未配對的存取點,並按一下•Pair。
6. 在•Pairing Passphrase 對話方塊中,輸入 AP 裝置的密碼。預設密碼為 wgwap。
如需有關•XTM•裝置的•WatchGuard AP•配對、管理及組態的詳細資訊,請參閱防火牆••
XTM Web UI•或•WSM•說明的「WatchGuard AP•裝置設定」區段,網址為•(http:www.watchguard.
com/help/documentation/xtm.asp).
1920
Page 12
Certications
Product Safety Certications
The WatchGuard product is safety certied under the following standards:
• CAN/CSA C22.2 No.60950-1-07+A1:2011
• IEC 60950-1+Amd1 2nd Edition (2005)
• UL 60950-1:2007 R12.11
• EN 60950-1:2006+A11+A1+A12
Safety Warning
• Do not place objects on the power cord.
• Do not obstruct the ventilation openings. These openings prevent overheating of the machine.
• Never push objects of any kind into slots or openings on this equipment. Making a contact with a
voltage point or shorting out a part may result in re or electrical shock.
• When removing or installing an appliance, follow the general installation safety instructions.
Disclaimer
WatchGuard shall not be held liable if the end user alters, modies, or repairs any WatchGuard
hardware appliance.
HINWEISE ZUR SICHERHEIT
Alle WatchGuard Produkte werden entwickelt und getestet, um strenge Sicherheitsanforderungen zu
erfüllen. Diese Anforderungen umfassen Produktsicherheit Zulassungen und andere globale ComplianceStandards. Bitte lesen Sie die folgenden Anweisungen sorgfältig, bevor Sie das Produkt, und bezeichnen sie
als notwendig, um den sicheren Betrieb des Geräts zu gewährleisten. Weitere Informationen nden Sie in
der elektronischen Hardware Guide.
Die WatchGuard Produkt ist Sicherheit unter den folgenden Normen zertiziert:
• CAN/CSA C22.2 No.60950-1-07+A1:2011
• IEC 60950-1+Amd1 2nd Edition (2005)
• UL 60950-1:2007 R12.11
• EN 60950-1:2006+A11+A1+A12
Sicherheitshinweis
• Legen Sie keine Gegenstände auf das Netzkabel.
• Verdecken Sie nicht die Lüftungsönungen. Diese Önungen verhindern eine Überhitzung
der Maschine
• Stecken Sie niemals Gegenstände jeglicher Art in die Schlitze oder Önungen des Geräts stecken.
Der Kontakt mit einem spannungsführenden Punkt oder das Kurzschließen eines Bauteils kann zu
einem Brand oder elektrischen Schlag führen.
• Beim Entfernen oder Installieren eines Gerätes, nach den allgemeinen Installation
Sicherheitshinweise.
AVISO DE SEGURIDAD
Todos los productos WatchGuard están diseñados y probados para satisfacer estrictos requisitos de
seguridad. Estos requisitos incluyen la homologación de productos de seguridad y otras normas de
cumplimiento global. Por favor, lea atentamente las siguientes instrucciones antes de utilizar el producto, y
se reeren a ellos como sea necesario para garantizar el funcionamiento seguro y continuo de su producto.
Información adicional se puede encontrar en la Guía del usuario electrónica.
Certicación de seguridad del producto
El producto tiene certicación de seguridad WatchGuard bajo las siguientes normas:
• CAN/CSA C22.2 No.60950-1-07+A1:2011
• IEC 60950-1+Amd1 2nd Edition (2005)
• UL 60950-1:2007 R12.11
• EN 60950-1:2006+A11+A1+A12
Advertencia de seguridad
• No coloque objetos sobre el cable de alimentación.
• No obstruya las aberturas de ventilación. Estas aberturas evitan el sobrecalentamiento de
la máquina.
• Nunca introduzca objetos de ningún tipo en las ranuras o aberturas del equipo. El contacto
con puntos de voltaje o el cortocircuito de una pieza podría provocar un incendio o una
descarga eléctrica.
• Al extraer o instalar un electrodoméstico, siga las instrucciones generales de instalación
de seguridad.
2122
Page 13
Certications
FCC Certication
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
* FCC Caution: Any changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.
Dieses Gerät wurde getestet und entspricht den Grenzwerten für ein Digitalgerät der Klasse A gemäß
Teil 15 der Federal Communications Commission (FCC) Regeln einhalten. Diese Grenzwerte sollen einen
angemessenen Schutz vor schädlichen Störungen, wenn das Gerät in einer kommerziellen Umgebung
betrieben wird. Dieses Gerät erzeugt, verwendet und kann Hochfrequenzenergie abstrahlen, und
wenn nicht installiert und in Übereinstimmung mit der Bedienungsanleitung, kann es Störungen im
Funkverkehr verursachen. Der Betrieb dieses Gerätes in einem Wohngebiet wird wahrscheinlich schädliche
Interferenzen in dem Fall muss der Benutzer die Störungen auf seine / ihre eigene Kosten zu beheben.
CE Notice
The CE symbol on your WatchGuard Technologies equipment indicates that it is in compliance with the
Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union
(EU).
2324
Page 14
Certications
Industry Canada Certication
This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Ce dispositif est conforme à la norme CNR-210 d’Industrie Canada applicable aux appareils radio exempts
de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas
produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un
brouillage susceptible de provoquer un fonctionnement indésirable.
R&TTE Compliance Statement
This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following test
methods have been applied in order to prove presumption of conformity with the essential requirements
of the R&TTE Directive 1999/5/EC.
RoHS Statement
The member states of the European Union approved directive 2002/95/EC, Restrictions of Hazardous
Substances (“RoHS directive”‘) that became valid on July 1, 2006. It states that all new electrical and
electronic equipment put on the market within the member states must not contain certain hazardous
materials. This device complies with the European Union’s R0HS directive 2002/95/EC and similar
regulations that may be adopted by other countries for European Sales.
WEEE Statement
WEEE is a general set of requirements dictated in the EU Directive 2002/96/EC. This Directive mandated
that member EU countries enact regulations governing the Waste of Electrical and Electronic Equipment
(WEEE). The Directive, and its individual transpositions into specic country laws and legislation, is aimed at
the reduction of WEEE through reuse, recovery, and recycling of WEEE.
WatchGuard is working in partnership with our European Union (EU) distribution partners to ensure
that our products are in compliance with the WEEE statutes, and that the recovery of our product per
the specic EU country legislative requirements is seamless for our product’s end users. If you have a
WatchGuard product that is at its end of life and needs to be disposed of, please contact WatchGuard
Customer Care Department at:
U.S. Customers: 877.232.3531
International Customers: +1.206.613.0456
WatchGuard is reasonably condent that our products do not contain any substances or hazardous
materials presently banned by any legislation, and do not present a risk due to hazardous materials. WEEE
recovery professionals should also note that these products do not have any materials that are of particular
high value in their individual form.
2526
Page 15
Certications
REACH Certicate of Compliance
The new EU chemicals policy REACH (Registration, Evaluation, Authorization and restriction of Chemicals)
came into eect on June 1, 2007. REACH is Europe’s new chemicals legislation, which is applicable in all
27 EU Member States as well as the EFTA European Economic Area (EEA). REACH creates a new system
for gathering information, assessing risks to human health and the environment, and authorizing or
restricting the marketing and use of chemicals produced or supplied in the EEA. REACH has an impact
on EEA producers and importers of nished products and users of chemicals in the course of industrial or
professional activities.
WatchGuard supports the overall REACH objective of improving the protection of human health and
the environment and will meet all applicable REACH requirements. WatchGuard is strongly committed
to working with our customers and supply chain to dene and implement the REACH requirements and
ensure a smooth transition to compliance.
One of the REACH requirements is that manufacturers and importers have the duty to register substances
they are producing or importing. In accordance with the regulations, the products of WatchGuard do not
need to be registered for the following reasons:
• WatchGuard does not import more than 1 metric ton per year of a substance as dened by REACH.
• WatchGuard products are non-chemical products that are not designed to release any substance
under normal and reasonably predictable application.
Our products do not contain the listed substances at more than 0.1% by weight of the whole product/part.
Brazil
Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência
prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em
caráter primário.
France
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation
à l’intérieur an de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles
utilisant les mêmes canaux;
(ii) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont
désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5 250-5 350 MHz et 5 650-5
850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL.
China
VCCI Notice Class A ITE (Japan)
Korea
기 종 별사 용 자 안 내 문
A 급 기기
(업무용방송통신기자재)
After sales information:
IT LOGIN JOEUN
#1402, 14F Yongsungbiztel 314-1 Woori-venturetownII 3F, 82-29
Hangangro-2ga Yongsangu Seoul, Korea
Seoul, SEOU 140-750 Seoul, SEOU 140-750
사용자안내문
이 기기는 업무용(A 급) 전자파적합기기로서 판매
자 또는 사용자는 이 점을 주의하시기 바라며, 가
정외의 지역에서 사용하는 것을 목적으로 합니다.
2728
Page 16
Certications
Mexico
Este La operación de este equipo está sujeta a las siguientes dos condiciones:
1. es posible que este equipo o dispositivo no cause interferencia perjudicial y
2. este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar
su propia operación no deseada.
Taiwan Class A Type Device
WatchGuard Technologies Inc. hereby declares that the product(s) listed below conform to the
Product (s):
Wireless Access Point, Model AP100 & AP200
EU Directive(s):
Radio & Télécommunications Terminal Equipment (1999/5/EC) Low Voltage (2006/95/EC)
Electromagnetic C ompatibility (2004/108/EC)
Energy-related Products (2009/125/EC)
Common Standard(s):
EN 60950-1:2006;Am11:2009+Am1:2010+Am12:2011Safety of ITE
EN 55022:2010Class A Emissions for ITE
EN 55024:2010Immunity for ITE
EN 61000-3-2:2006+A1:2009+A2:2009Harmonics
EN 61000-3-3:2008Flicker
Wireless Standard(s):
EN 301 489-01 v1.9.2 (2011-09)EMC and Radio Spectrum Matters
EN 301 489-17 v2.1.1 (2009-05)EMC and Radio Spectrum Matters
EN 300 328 v1.7.1 (2006-10)Radio Spectrum Matters
EN 301 893 v1.6.1 (2011-11)Broadband Radio Access Networks
In accordance with the Radio and Telecommunications Terminal Equipment Act (FTEG) and
Directive 1999/5/EC (R&TTE Directive).
Manufacturer / Hersteller:WatchGuard Technologies
Radio Equipment / Funkanlage:Wireless Access Point
Type Designation / Typenbezeichnung:AP100 & AP200
Specifications / Technische Daten:802.11a,b,g,n (2.4Ghz & 5GHz)
Intended Purpose / Verwendungszweck:Indoor Access Point
Equipment Class / Betriebsmittel der K lasse:Class II
The above device complies with the essential requirements and other relevant provisions to Directive
1999/5/EC when used for its intended purpose. This equipment may be operated in the USA, Canada, Europe Union
& Australia-New Zealand.
Warning! This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Restrictions: Italy – For private use, a general authorization is required if this device is used outside own premises.
Norway – This device does not apply for the geographical area within a radius of 20 km from the center of Ny-
Alesund.
Die oben genannten Gerät entspricht den grundlegenden Anforderungen und anderen relevanten Bestimmungen der
Richtlinie 1999/5/EG, wenn für den vorgesehenen Zweck verwendet werden. Dieses Gerät ist für die Verwendung in
den USA, Kanada, Europäische Union & Australia-New Zealand betrieben werden.
Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen
verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen durchzuführen
Beschränkungen: Italien – Für den privaten Gebrauch ist eine allgemeine Genehmigung erforderlich, wenn das
Gerät außerhalb der eigenen Räumlichkeiten verwendet wird. Norwegen – Dieses Gerät darf nicht in den
geografischen Gebieten innerhalb eines Radius von 20 km vom Zentrum von Ny-Ålesund verwendet werden.
European Union directives and standards identified in this declaration.
Declaration of Conformity
505 5thAve S. Suite 500, Seattle, WA 98104
Signature:
Full Name: Steve Zirschky
Position:
Date: June 19, 2012
ADDRESS: 505 Fifth Avenue South, Suite 500, Seattle, WA 98104