WatchGuard AP125 User Manual

WatchGuard
AP125
AP125
Hardware
Guide
Copyright and Patent Information
Copyright© 2019 WatchGuard Technologies, Inc. All rights reserved. WatchGuard, the WatchGuard logo, LiveSecurity, and any other mark listed as a trademark in the “Terms of Use” portion of
the WatchGuard Web site that is used herein are either registered trademarks or trademarks of WatchGuard Technologies, Inc. and/or its subsidiaries in the United States and/or other countries. All other trademarks are the property of their respective owners.
Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this guide may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of WatchGuard Technologies, Inc.
Revised: November 21, 2019
Complete copyright, trademark, patent, and licensing information can be found in the WatchGuard product documentation. You can find this document online at:
https://www.watchguard.com/help
ABOUT WATCHGUARD
WatchGuard® Technologies, Inc. is a global leader in network security, providing best­in-class Unified Threat Management, Next Generation Firewall, secure Wi-Fi, and network intelligence products and services to more than 75,000 customers worldwide. The company's mission is to make enterprise-grade security accessible to companies of all types and sizes through simplicity, making WatchGuard an ideal solution for Distributed Enterprises and SMBs. WatchGuard is headquartered in Seattle, Washington, with offices throughout North America, Europe, Asia Pacific, and Latin America. To learn more, visit WatchGuard.com.
For additional information, promotions and updates, follow WatchGuard on Twitter, @WatchGuard on Facebook, or on the LinkedIn Company page. Also, visit our InfoSec blog, Secplicity, for real-time information about the latest threats and how to cope with them at www.secplicity.org.
ii WatchGuard AP125
ADDRESS
505 Fifth Avenue South Suite 500 Seattle, WA 98104
SUPPORT
www.watchguard.com/support U.S. and Canada +877.232.3531 All Other Countries +1.206.521.3575
SALES
U.S. and Canada +1.800.734.9905 All Other Countries +1.206.613.0895

Hardware Specifications

The WatchGuard® AP family of wireless access points provide secure, reliable, wireless communications while delivering high performance and broad coverage—a perfect combination of services to meet the needs of enterprise-level customers, small businesses, branch offices, campuses, and hotels alike.
Internal antennas, slim cases, minimalist labeling, and small LEDs, coupled with wall and ceiling mount options, make these devices ideal for low profile deployment scenarios. Power can be provided by any Power over Ethernet (PoE) power source or an AC adapter.
WatchGuard AP125 devices are enterprise grade 802.11ac Wave 2 access points for low density environments such as small schools, distributed remote offices, small footprint retail stores, and restaurants.
There are two ways you can manage your AP:
Total Wi-Fi and Secure Wi-Fi with WatchGuard Wi-Fi Cloud
A powerful cloud-based enterprise wireless management solution for AP configuration, security, and monitoring.
Basic Wi-Fi with WatchGuard Firebox Gateway Wireless Controller
Local management, configuration, security, and monitoring of APs directly from your WatchGuard Firebox. The WatchGuard Firebox requires Fireware OS v12.1.3 and higher.
For more information about how to set up and manage your WatchGuard AP, you can find documentation online at: https://www.watchguard.com/help
Hardware Guide 1

Hardware Specifications

Package Contents
WatchGuard AP125Quick Start GuideMounting bracket for T-rail ceilings (15/16”, 24mm)
Optional mounting accessories for walls or ceilings without a T-rail, or different size T-rail ceilings are also available from WatchGuard. For more information, see “Mounting Instructions” on page 8.

About Your Hardware

Hardware Specifications
AP125
Processor and RAM Qualcomm IPQ4028 717 MHz quad-core ARM
processor with 256 MB RAM and 64 MB Flash
Radio Type and Frequency Band
Antenna 4 integrated omnidirectional antennas
Ethernet interface 1 x 10/100/1000 Mbps Gigabit Ethernet (LAN2)
Power Interface Power over Ethernet: 802.3af (PoE)
Power Consumption Max: 12.95 W
MTBF Rating 2,080,309 hours at 25°C
Dimensions 148mm × 148mm × 33mm Weight 0.522 lb (237 g)
2.4GHz, 802.11b/g/n. Max data rate: 300 Mbps 5GHz, 802.11a/n/ac. Max data rate: 876 Mbps
2 antennas: 2.4GHz radio2 antennas: 5GHz radio
802.3af PoE
1 x 10/100/1000 Mbps Gigabit Ethernet (LAN1) for link aggregation or a wired extension.
PoE input voltage 48V, Class 0
DC jack: 12V DC input, 1.5A (5.5mm overall diameter/2.1mm center pin/hole)
Min: 2.7 W Average: 11 W
952,320 hours at 45°C
2 WatchGuard AP125
Environmental Requirements
To safely install your WatchGuard AP, we recommend that you:
Install the device indoorsMake sure the device has adequate clearance for air flow and coolingConnect it to a surge-protected power supply to prevent damage from sudden power changes
Other environmental requirements:
Environmental Requirements
Operating temperature 0°C to 45°C (32°F to 113°F) Operating relative humidity 0% to 95% non-condensing Non-operating temperature -20°C to 65°C (-4°F to 149°F) Non-operating relative humidity 5% to 95% non-condensing
Hardware Specifications
Hardware Guide 3
Hardware Specifications
Hardware Description

Device Connections and Buttons

Ethernet Network Interfaces
LAN2 (PoE): Standard RJ45 connector that supports link speeds of 10/100/1000 Mbps and PoE connectivity.
LAN1: Standard RJ45 connector that supports link speeds of 10/100/1000 Mbps.
When configured with Wi-Fi Cloud, this second AP interface can be used for link aggregation or as a wired extension for a wireless SSID that has NAT enabled. For more information, see the WatchGuard Wi-Fi Cloud Help.
For APs managed locally by a Gateway Wireless Controller with Fireware v12.2.1 and higher, you can bridge together the LAN ports on AP models that have two LAN interfaces. This enables you to extend the wired network on the second LAN interface. For more information, see the Fireware Help.
Reset
Resets the WatchGuard AP to factory-default settings. You must use a paper clip or other small object to press the reset button through the small hole on the AP.
To reset the AP to factory-default settings, while the AP is powered on, press and hold the reset button for up to 10 seconds until the LEDs go off to indicate that the AP has rebooted.
If you press the reset button while the AP is not powered on or is booting, the reset button will have no effect.
4 WatchGuard AP125
Hardware Specifications
Power Input (DC IN)
The WatchGuard AP125 can be powered by 802.3af PoE on the LAN2 (PoE) interface.
You can also power the device with an optional AC power adapter. For more information, see “AC Power Adapter” on page 15.
Hardware Guide 5
Hardware Specifications
Device Indicators
The front panel of the AP125 has five LEDs that indicate the status of the AP.
AP Firmware 8.8.1 and Higher
LED Status
Off Powered off. No Ethernet
Green Powered on. Operating at normal
Flashing Green
Orange - Connected at
Flashing Orange
Power LAN 1 and
power and capabilities. (PoE+ or DC power, or PoE for
802.3af only APs) Not connected to Wi-Fi Cloud or
paired with a Gateway Wireless Controller
OR
No IP address received from DHCP.
---
2.4 GHz and 5 GHz
LAN2
link.
- Radio active.
--
10/100/1000 Mbps.
Radios
Radio inactive.
-
6 WatchGuard AP125
AP Firmware 8.8.0 or Lower
LED Status Description
Power Solid green Power On LAN1 Off Power Off
Solid amber Connected to LAN1 port at
10/100/1000 Mbps. Flashing amber Activity on LAN1 port. Off No Ethernet link.
LAN2/PoE Solid green Connected to LAN2/PoE port at
10/100/1000 Mbps. Fast flash green Did not receive valid IP address from
DHCP. Slow flash green Cannot connect to WatchGuard Wi-Fi Cloud. Flashing green Activity on LAN2/PoE port. Off No Ethernet link.
2.4 GHz Solid green Client connected to 2.4 GHz radio. Flashing green Activity on 2.4 GHz radio.
5 GHz Solid green Client connected to 5 GHz radio.
Flashing green Activity on 5 GHz radio.
Hardware Specifications
Hardware Guide 7
Hardware Specifications
Mounting Instructions
Your package includes the AP125 and a T-rail mounting bracket.
The MAC address and serial number of your AP are printed on a label on the back of the device. Make sure you record this information before you mount the AP.
8 WatchGuard AP125

T-rail Brackets

Use the included mounting bracket (15/16”, 24mm, Part #: WG8027) to install the AP125 on a ceiling with a T-rail.
Optional T-rail mount brackets are available from WatchGuard:
9/16” T-rail mount, 15mm, Part #: WG8026Interlude/Silhouette T-rail mount, 15mm, Part #: WG8021
Hardware Specifications
1. Put the first mounting post on the back of the AP over the lower bracket notch and rotate into place.
2. Make sure that all the mounting posts on the back of the AP are securely positioned in their bracket notches.
3. To attach the bracket to the T-rail, rotate the bracket so it is parallel to the T-rail, and snap the bracket on the T-rail.
Hardware Guide 9