3
WatchDog Weather Stations have external ports available for external
sensor input (Models 525, 550, 600 and 700 have 4, Model 900ET has 3).
The following table lists the available optional sensors. All sensors include
a 6-foot cable with pin-type connector.
To connect an external sensor to the logger, plug the sensor cable into the
logger port that has been programmed for that particular sensor. If the
sensor is not connected, the message “sensor error” will appear on the LCD
display for the respective logger port until the sensor is connected.
External Sensors
Item #
Sensor
Description
Measurement
Range
Max #
per
station
Accuracy
3666 Leaf Wetness 0(Dry) - 15(Wet) 2 N/A
3667 (6ft)
3667-20 (20ft)
External (Soil)
Temperature
-30° to 100°C
-22° to 212° F
3 ±0.7°C
±1°F
3670 Silicon
Pyranometer
1-1250 W/m2 1 ±5%
3668 Quantum Light 0-2500 µmol/m2/s 2 ±5%
3669,
3669LT
Soil Moisture
Transducer
0-100 kPa (R-type)
0-40 kPa (LT-type)
2 ±2%
6450WD (6ft)
6450WD20
Watermark Soil
Moisture Sensor
0-200 kPa (WM-type)
3 N/A
3664 20 ft. Extension
Sensor Cable
N/A N/A N/A
6451 Irrigation Sensor Switches at 5 psi 1 ±1 psi
6471 Barometric
Pressure Sensor
26 - 32 in Hg
660 - 810 mm Hg
1 ±0.05”
±1.3 mm
3673
3674
Input Cable for
User Supplied
Sensor
0 - 2.5V
4 - 20mA
3 N/A
Program each port to a specific sensor through the Launch Options Screen in
SpecWare software.
Anemometer setup
Apart from the
anemometer, the
WatchDog Weather Station
comes fully assembled and
ready to mount. The
anemometer arm is
attached to the enclosure
back plate with two
clamps. After positioning
the arm, the screws should
be tightened to secure it in
place.
Push the wind cups onto the bottom
of the shaft flush with the bottom of
the assembly and tighten the set
screw. When released, the cups
should drop slightly. If the cups do
not spin freely, loosen the set screw
and lower the cups slightly. The gap
between cup hub and assembly
should be about 1/16 inch.
Push the wind vane onto the top of
the shaft and calibrate (see next page
for calibration procedure).
Anemometer clamped to back plate