Wassermann Dental-Maschinen HSM-500 User Manual

WASSERMANN DENTAL
-
MASCHINEN GMBH
User manual
HSM-500 bench top rotary tool
- 1 -
Dear customer,
Thank you for choosing a product from the Wassermann range. Wassermann dental equipment incorporates the highest standards of quality and the latest technology. In order to enjoy maximum performance and years of trouble-free operation from the equipment, please read this user manual carefully before you start work, and operate the unit according to the recommended guidelines. Please ensure that all persons operating the equipment have read and understood this user manual.
Keep this user manual on hand for ready reference.
Company address:
Wassermann Dental-Maschinen GmbH Rudorffweg 15-17 D-21031 Hamburg Germany Tel.: +49 (0)40/ 730 926 - 0 Fax.: +49 (0)40/ 730 37 24 e-mail: info@wassermann-dental.com URL: http// www.wassermann-dental.com
Erstellt von: Ap Erstellt: 10.09.2005 Version: 1
Auftrag: 111994/006
- 2 -
Contents
Contents....................................................................................................................................2
1 For your safety..................................................................................................................3
1.1 CORRECT USE OF THIS PRODUCT ...................................................................................3
1.2 SAFETY SYMBOLS USED IN THIS MANUAL.........................................................................3
1.3 SAFETY GUIDELINES......................................................................................................3
1.4 HANDPIECE BLOCK........................................................................................................4
1.5 RESPONSIBILITY FOR OPERATION AND DAMAGE...............................................................4
1.6 AUTHORIZED USERS......................................................................................................5
2 Care and maintenance......................................................................................................5
2.1 MAINTENANCE ..............................................................................................................5
2.2 CARE ...........................................................................................................................6
2.3 CLEANING AND/OR CHANGING THE CHUCK.......................................................................6
3 Use / Application...............................................................................................................7
4 Before you start.................................................................................................................7
4.1 UNPACKING / TRANSPORT .............................................................................................7
4.2 CONTENTS....................................................................................................................8
5 Switch functions ...............................................................................................................8
5.1 POWER SWITCH ..........................................................................................................8
5.2 CONTROL ROCKER SWITCH.........................................................................................8
5.3 DIRECTION ROCKER SWITCH.......................................................................................8
5.4 SPEED-CONTROL KNOB .................................................................................................8
5.5 CHANGING ROTATING TOOLS..........................................................................................9
6 Installation.........................................................................................................................9
6.1 INSTALLING THE MOTOR, MAINS AND FOOT-SWITCH CABLES .............................................9
6.2 REMOVING AND ASSEMBLING THE MOTORISED HANDPIECE.............................................10
7 Start-up............................................................................................................................10
8 Troubleshooting / Correcting errors..............................................................................11
8.1 FAULTS ......................................................................................................................11
8.2 TECHNICAL DATA.........................................................................................................11
8.3 SPARE PARTS .............................................................................................................12
8.4 REPAIRS.....................................................................................................................12
9 Warranty ..........................................................................................................................12
10 EC conformity certificate............................................................................................13
- 3 -
1 For your safety
1.1 Correct use of this product
This laboratory equipment is designed for working with dental materials (stainless steels, plastics, ceramics, etc.) in dental laboratories using rotating tools.
1.2 Safety symbols used in this manual
Warning! This is a warning of risk situations and dangers. Failure to observe this warning could be life-threatening. These warnings must be observed.
Information!
This symbol draws your attention to specific features, which must be observed.
1.3 Safety guidelines
Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual. The equipment is designed only for
its intended application.
Servicing and repairs should be carried out only by authorised specialists.
Make sure that the unit is connected to the correct mains voltage.
!
i
!
!
- 4 -
Danger! Do not touch the tool when it is rotating or coming to a stop! Be sure to follow the manufacturer’s guidelines for the maximum permissible speed of the rotating tools used.
Take the following precautions before starting work:
Wear eye protection
Use a protective visor
1.4 Handpiece block
This rotary tool features electronically controlled overload protection. If an excessive load blocks the handpiece, the motor switches off automatically and the red LED flashes. The handpiece stops if the chuck is open, and the electronics also cut out if the tool starts working accidentally.
1.5 Responsibility for operation and damage
The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced, maintained or altered by persons not employed by an accredited dealer or if the unit is used in a manner contrary to its specified purpose. The unit must be maintained and operated in accordance with this user manual. Wassermann Dental-Maschinen GmbH is not responsible for damage arising from the non-observance of these instructions. Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental-Maschinen GmbH are not extended by these instructions.
Product responsibility lapses if the equipment is altered by unauthorized third parties or if non-original parts are installed. Use only original WASSERMANN replacement parts.
!
!
!
Loading...