Wassermann WW-33 User Manual

Hydraulic Press
WW-33
2-4 flasks 1-3 flasks (Fig.)
USER MANUAL
Dear customer,
Maschinen incorporates the highest standards of quality and the latest technology.
In order to enjoy maximum performance and years of trouble-free operation, please read
this user manual carefully before you connect this device and start work, and operate the
device according to the recommended guidelines. The operation safety and the
functionality of this device can only be guaranteed if you follow both the general safety
guidelines and the applying laws to prevent accidents as well as the precautions given in
this user manual. We are not liable for any damages which occur due to inappropriate
usage or faulty operation of this device.
Make sure that anyone using this device has read and understood this user
manual.
Keep this user manual in a safe place where it can be referred to as required at
any time.
The unit complies with the relevant EU guidelines.
Company address:
Wassermann Dental-Maschinen GmbH
Rudorffweg 15-17
21031 Hamburg, Germany
Phone : +49 (0)40 730 926 -20/ -24 Fax.: +49 (0)40 730 37 24
export@wassermann-dental.com
www.wassermann.hamburg
Erstellt: 26.07.17/ msc Version: 1 Auftrag: 126999/091 // 126998/088
.
Contents
1 Features.............................................................................................................................4
2 Safety Symbols used in this Manual..................................................................................5
3 Safety Guidelines...............................................................................................................5
4 Responsibility for Operation or Damage............................................................................6
5 Application..........................................................................................................................6
6 Before Starting...................................................................................................................6
6.1 Transport.....................................................................................................................6
6.2 Installation...................................................................................................................7
6.3 Storage........................................................................................................................7
7 Installation/ Start-up...........................................................................................................7
8 Operation...........................................................................................................................8
8.1 General Operating Instructions...................................................................................8
9 Troubleshooting.................................................................................................................9
9.1 Guidelines for Venting:................................................................................................9
10 Care and Maintenance...................................................................................................10
10.1 Cleaning..................................................................................................................10
10.2 Maintenance............................................................................................................10
10.3 Repairs....................................................................................................................10
10.4 Spare Parts..............................................................................................................11
10.5 Service Hotline 0049 (0)40 730 926 -20/ -24..........................................................11
10.6 Scope of Delivery/ Accessories...............................................................................11
10.7 Warranty..................................................................................................................11
11 Technical Data...............................................................................................................12
12 EU Declaration of Conformity........................................................................................13
1 Features
The WW-33 hydraulic press, with continuous pressure up to 6 tonnes, presses caps
individually and appropriately for the material used. After ending one pressing, it is
immediately ready for further use as its solid plastic piston returns automatically once the
valve has been opened. A quality pressure gauge which shows the pressure achieved with
great accuracy, is recessed into the housing and is thus protected from dirt. The WW-33’s
oxidation-free piston (plastic), tensile steel construction (no risk of breaking), and sturdy
plastic-coated housing all contribute to the unit’s long service life. As the distance between
supports is 152 mm, the press is also suitable for larger caps (IVOCAP) and stirrup pieces.
SPECIAL DESIGN:
The WW-33 hydraulic press is also available with longer supports for 4 caps.
Break-proof hydraulic press in drawn steel for pressing 1–3 or 2–4 flasks
Pressure infinitely adjustable up to 6 tonnes
Rust-proof piston made of super-strong material
Automatic piston return after opening of valve
Plastic powder coated housing
Quality pressure gauge with precision display recessed in housing
Distance of columns of 152 mm to allow use of larger flasks and flask clamps
High stability
Integrated oil level display
4
2 Safety Symbols used in this Manual
Warning!
This is a warning of risk situations and dangers.
Failure to observe this warning could be life-threatening.
These warnings has to be observed.
Information!
This symbol draws your attention to specific features that has to be observed.
3 Safety Guidelines
Configuring and operating this equipment requires precise knowledge and observance
of the instructions in this user manual. The equipment is designed only for its intended
application.
WARNING:
Servicing and repairs should be carried out only by authorised specialists.
Disconnect the power plug before starting any maintenance work.
5
Loading...
+ 11 hidden pages