Wasp WWS850 User Manual

WWS800/850 Bluetooth Wireless Scanners
User’s Manual
© 2008 Wasp Technologies
Table of Contents
Revision History .......................................... Error! Bookmark not defined.
Restore Default Settings ...........................................................................1
Exit Setup without Changes .....................................................................1
Set Connection...........................................................................................1
RF Auto Shutdown Duration ...................................................................1
Transmit Buffer Setting............................................................................1
Memory Mode Parameters.......................................................................2
List Setting................................................................................................. 3
Buzzer Settings ..........................................................................................3
Reading Redundancy Setting ...................................................................4
Scan Mode Setting..................................................................................... 4
Auto-Sense Setting ....................................................................................4
Scanner Time-out Duration......................................................................5
Negative Barcode Setting..........................................................................5
Delay between Reread ..............................................................................5
Keyboard Wedge Parameters ..................................................................6
RS-232 Parameters....................................................................................9
Bluetooth Serial Port Parameters .......................................................... 11
Bluetooth HID Parameters..................................................................... 12
Prefix / Postfix Settings...........................................................................15
Character Substitution ...........................................................................15
Code ID Selection ....................................................................................15
Code ID Setting .......................................................................................16
Length Code Setting (2 digits)................................................................17
Select Readable Codes ............................................................................20
Code39 Parameters .................................................................................25
Italy Pharmacode Parameters................................................................25
French Pharmacode Parameters............................................................26
Industrial 25 Parameters ........................................................................26
Interleave 25 Parameters........................................................................27
Matrix 25 Parameters .............................................................................29
Codabar Parameters...............................................................................30
Plessey Parameters.................................................................................. 31
Telepen Parameters.................................................................................31
MSI Parameters ......................................................................................32
EAN128 Parameters................................................................................33
EAN8 Parameters....................................................................................34
UPCA Parameters...................................................................................34
UPCE Parameters ...................................................................................35
EAN13 Parameters..................................................................................36
RSS Code ID Selection............................................................................ 37
RSS14 Parameters...................................................................................37
RSS Limited Parameters ........................................................................38
RSS Expanded Parameters ....................................................................38
Activate Editing Formats ....................................................................... 39
Editing Format Parameters.................................................................... 40
Decimal Digits.......................................................................................... 52
Hexadecimal Digits.................................................................................. 53
Key Type.................................................................................................. 54
Key Status................................................................................................ 54
KBD Wedge Character Table ................................................................55
RS-232 Character Table.........................................................................55
1
Update
Restore Default Settings
Restore Default SettingsRestore Default Settings
Restore Default Settings
Exit Setup without Changes
Exit Setup without ChangesExit Setup without Changes
Exit Setup without Changes
Set Connection
Set ConnectionSet Connection
Set Connection
*
Programming Instructions: (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired 3666 Base Station within 5 seconds to complete this setting.
RF Auto Shutdown Duration
RF Auto Shutdown DurationRF Auto Shutdown Duration
RF Auto Shutdown Duration
*
Programming Instructions: (1) Read the label. (2) Program the desired auto shutdown duration (in minutes) by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
Transmit Buffer Setting
Transmit Buffer SettingTransmit Buffer Setting
Transmit Buffer Setting
Enable
< Disable >
2
Enter Setup
Memory
Memory Memory
Memory Mo
MoMo
Mode
dede
de Parameters
Parameters Parameters
Parameters
Memory Mode
Enable
< Disable >
Clear Data
Clear
Confirm
Send Data
Memory Data Delay
< 0 >
2 sec
250 ms
3 sec
500 ms
5 sec
1 sec
8 sec
3
Update
List Setting
List SettingList Setting
List Setting
Page1
Page 6
Page 2
Page 7
Page 3
Page 8
Page 4
Page 9
Page 5
Page 10
Buzzer Settings
Buzzer SettingsBuzzer Settings
Buzzer Settings
< Buzzer Enable>
Buzzer Disable
Buzzer Frequency
8 kHz
< 4 kHz >
2 kHz
1 kHz
4
Enter Setup
Reading Redundancy Setting
Reading Redundancy SettingReading Redundancy Setting
Reading Redundancy Setting
< No Redundancy >
2 Times
3 Times
4 Times
Scan Mode Setting
Scan Mode SettingScan Mode Setting
Scan Mode Setting
< Auto Off Mode >
Continuous Mode
Auto Power Off Mode
Alternate Mode
Momentary Mode
Repeat Mode
Laser Mode
Test Mode
Auto
AutoAuto
Auto----Sense Setting
Sense SettingSense Setting
Sense Setting
Enable
<Disable>
5
Update
Scanner Ti
Scanner TiScanner Ti
Scanner Time
meme
me-out Duration
out Durationout Duration
out Duration
*
Programming Instructions: (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
Negative Barcode Setting
Negative Barcode SettingNegative Barcode Setting
Negative Barcode Setting
Enable
< Disable >
Delay between Reread
Delay between RereadDelay between Reread
Delay between Reread
100 ms
1 sec
200ms
2 sec
< 400 ms >
3 sec
800 ms
5 sec
6
Enter Setup
Keyboard Wedge Parameters
Keyboard Wedge ParametersKeyboard Wedge Parameters
Keyboard Wedge Parameters
Activate and Select Keyboard Type
*
Programming Instructions: (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
Keyboard Table
No. Keyboard Type
1 PCAT (US) 2 PCAT (French) 3 PCAT (German) 4 PCAT (Italy) 5 PCAT (Swedish) 6 PCAT (Norwegian) 7 PCAT (UK) 8 PCAT (Belgium)
9 PCAT (Spanish) 10 PCAT (Portuguese) 11 PS55 A01-1 12 PS55 A01-2 13 PS55 A01-3 14 PS55 001-1 15 PS55 001-81 16 PS55 001-2 17 PS55 001-82 18 PS55 001-3 19 PS55 001-8A 20 PS55 002-1, 003-1 21 PS55 002-81, 003-81 22 PS55 002-2, 003-2 23 PS55 002-82, 003-82 24 PS55 002-3, 003-3 25 PS55 002-8A, 003-8A 26 IBM 3477 (Japanese) 27 PS2-30 28 IBM 34XX/319X, Memorex Telex 122 Keys
7
Update
Keyboard Alphabets Layout
< Default Layout >
AZERTY
QWERTZ
Keyboard Digits Layout
< Default Layout >
Lower Row
Upper Row
Keyboard Capital Lock Type
< Default >
Shift Lock
Capital Lock
Capital Lock Setting
Capital Lock ON
< Capital Lock OFF >
Auto Detection
8
Enter Setup
Alphabet Transmission
< Case Sensitive >
Ignore Case
Digits Transmission
< Alphanumeric Key >
Numeric Key
Alt Composing
Yes
< No >
Inter-Character Delay
*
Programming Instructions: (1) Read the label. (2) Program the desired inter­character delay by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
Laptop Support
<Disable>
Enable
9
Update
RS
RSRS
RS----232 Parameters
232 Parameters232 Parameters
232 Parameters
Activate RS232 Interface
Baud Rate
115200
38400
119200
< 9600 >
4800
2400
1200
Parity
Even
Odd
< No Parity >
Data Bit
< 8 >
7
10
Enter Setup
Flow Control
(single port only)
< None >
Scanner Ready
Data Ready
INV. Data Ready
Inter-Character Delay
*
Programming Instructions: (1) Read the label. (2) Program the desired inter­character delay by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
11
Update
Bluetooth Serial Port Parameters
Bluetooth Serial Port ParametersBluetooth Serial Port Parameters
Bluetooth Serial Port Parameters
Activate Bluetooth Serial Port Interface
Device Name Broadcasting
< Yes >
No
Authentication
Yes
< No >
PIN Code
*
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 54. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 54) to complete this setting. (4) Max 6 characters for this PIN Code setting.
12
Enter Setup
Bluetooth HID Parameters
Bluetooth HID ParametersBluetooth HID Parameters
Bluetooth HID Parameters
Activate and Select Keyboard Type
*
Programming Instructions: (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
HID Keyboard Table
No. Keyboard Type
64 PCAT (US) 65 PCAT (French) 66 PCAT (German) 67 PCAT (Italy) 68 PCAT (Swedish) 69 PCAT (Norwegian) 70 PCAT (UK) 71 PCAT (Belgium) 72 PCAT (Spanish) 73 PCAT (Portuguese)
Reset Connection
Please read this label when switching connection from one PC to another and
the reconnection is needed.
Device Name Broadcasting
< Yes >
No
13
Update
Authentication
Yes
< No >
PIN Code
*
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 54. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 54) to complete this setting. (4) Max 6 characters for this PIN Code setting.
Keyboard Alphabets Layout
< Default Layout >
AZERTY
QWERTZ
Keyboard Digits Layout
< Default Layout >
Lower Row
Upper Row
14
Enter Setup
Keyboard Capital Lock Type
< Default >
Shift Lock
Capital Lock
Capital Lock Setting
Capital Lock ON
< Capital Lock OFF >
Auto Detection
Alphabet Transmission
< Case Sensitive >
Ignore Case
Digits Transmission
< Alphanumeric Key >
Numeric Key
Alt Composing
Yes
<No>