SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating
the product. Failure to do so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication but are subject to change
without notice.
REV 20210312
Warrio r Power Equipm ent, Unit 17-18, Br adley Hall Tradi ng Estate,Bra dley Lane, Sta ndish, Wi gan, WN6 0XQ, Un ited Kingdo m
Page 2
WPE DIESEL GENERATORS
INTRODUCTION
INTRODUCTION
Thank you for purchasing our product.
This product is guaranteed against faulty manufacture
for a period of 24 months from the date of purchase.
Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have
been abused or tampered with in any way, or not used
for the purpose for which it was intended. Faulty goods should not be returned to the place of purchase,
the generator should be returned to the supplier of
the product. No product can be returned without
prior permission. This guarantee does not affect your
statutory rights.
When contacting WPE about parts and/or service,
you will need to supply the complete model and serial
numbers of your product. Transcribe the information
found on your product’s nameplate label to the table
below
WPE TECHNICAL SUPPORT TEAM
44(0)1942 715 407
MODEL NUMBER
SERIAL NUMBER
IMPORTANT
1. Children should be kept at a safe distance from the
generator and NEVER allowed to operate it.
2. Your new generator needs a break in period of
approx. 10 hours with NO more 75% maximum load
being applied. After first 10 hours the oil MUST
be changed, recommended oil 10W30 low or Non
Synthetic.
3. Don’t touch the engine or muffler while generator
is in operation. Please pay attention to warning and
caution stickers on the generator.
4. Electrical equipment (including cable and plug
connecting component) should be in good condition
before starting and inspected prior to use.
5. If replacing circuit breaker it must be equivalent or
better in specification of the one to be removed.
6. Due to high mechanical stress, only rubber sheathed
cables are recommended to be used.
7. When using extension cords or mobile distribution
cabinet, the wire with 1.5mm2 cross section should
not be longer than 50 metres; and for 2.5mm2 cross
section wire should not be longer than 100 metres in
length.
DATE OF PURCHASE
PURCHASE LOCATION
8. With manual starting, always use decompression
lever. (ONLY on Open Frame Type)
9. On standard working ambient conditions (minus
5 to 40 degree Centigrade), the generator can be
operated at normal running loads. If the working
condition of circumstance are not normal either
too high or too low, the generator should be run at
a lower output of no more than 75% maximum load.
When temperature, altitude and humidity is higher
than standard working condition, the generator
MUST reduce the output load to no more than 75%
maximum load.
10. Before any inspection or maintenance of the
generator, the engine must be stopped and allowed
to cool for a minimum 30 minutes. Check and
maintain the generator according to the period table
and schedule sheet in the manual.
11. Except the daily maintenance or cleaning, any
inspection or readjustment should be conducted
by authorized professional person and source the
requested original components by them from the
supplier. (Contact your local dealers).
12. Your newly overhauled machine must endure a
breaking-in period of at least 10 hours, the output
should not exceed 75% of the maximum load.
2
Page 3
WPE DIESEL GENERATORS
FEATURES
FEATURES
WPE Diesel generator possesses the following features:
This series diesel generator adopts super-light type, air
cooled, 4-stoke direct injection diesel engine and has two
starting options:
1. Recoil start
2. Electric start.
They are equipped with large capacity fuel tank, circuit
protector, A.C and sometimes D.C voltage outputs, low oil
pressure alarm and automatic stopping device.
The diesel generator serves as an UPS stand-by power
supply in many different applications including open
working site, construction and field army. Emergency
power of poultry farm, fishery, forestry, garden, hotel,
shop, and office.
This operation manual tells you how to operate and
service your new diesel generator. Please read it before
using the diesel generator to ensure proper handing
and operation. Following these instructions carefully will
keep your diesel generator in the best working condition,
allowing to prolong the life of your diesel generator.
If you have any questions concerning your new product
or any of the information given in this manual, please
contact 44(0)1942 715 407.
IMPORTANT
Please read and understand this operation manual to
insure safe operation, and pay high attention to the
following main points of operation otherwise it may
cause personal injury and damage to equipment.
Preventing fires
The fuel of diesel engine is light diesel fuel , so gasoline,
kerosene etc. must NEVER be used.
Wipe away all fuel spills with a clean cloth. Keep
gasoline, kerosene, matches and other explosives
and inflammable substance away from the generator,
because the temperature around the exhaust muffler is
very high during operation. To prevent fire hazards and
to provide adequate ventilation, keep the generator at
least 1.5 meter away from buildings, structures and other
equipment during operation.
Operate the generator on a flat level surface, there may
be fuel spillage or poor operation if the generator is tilted.
Preventing exhaust gas inhalation
Exhaust gas contains poisonous carbon monoxide.
Always use the generator in outdoor locations minimum
1.5m anyway from window, doors or opening.
Generators MUST never be used indoors, in garages,
cabins, out building, sheds or any confined spaces
including vehicles and vehicle compartments.
EN
PARAMETERS
The generators can generate specified power when used
in the following conditions:
Exhaust/mufflers and gases are very hot to
touch. DO NOT add or install any exhaust/muffler
extensions, by doing so you will void any warranty
offered.
Preventing burns
NEVER touch or handle exhaust/muffler, engine when
generator is running or hot, always leave approx 30
minutes for the exhaust/muffler & engine to cool before
handling.
Electric shocks, short circuits
In order to avoid electric shocks or short circuit, do not
touch the generator, when either it or your hands are wet.
This generator is not waterproof , so it should NEVER be
used in a place exposed to rain, snow or water sprays.
The generator should be ground to prevent electric
shocks. Please connect a length of heavy wire between
the generator’s ground terminal and an external ground
device, ground rod or stake - minimum 200mm deep.
Do not connect any equipment to the generator before
you start it.
WARNING
Most appliance motors require more than their rated
wattage for start up. Do not exceeded the current
limit specified for any one socket.
Charging the battery
Battery electrolyte contains sulphuric acid. Protect
your eyes, skin and clothing. In case of contact, flush
thoroughly with water and get prompt attention,
especially if your eyes are affected.
Batteries generate hydrogen gas, which can flames or
sparks near a battery, especially during charging.
Charge the battery in a fully ventilated area.
3
Page 4
WPE DIESEL GENERATORS
PREPARATION BEFORE START
WARNING
Know how to stop the generator quickly, and
understand how to operate all of the controls. Never
permit anyone to operate the generator without
proper instruction.
Always wear a helmet, safety shoes and proper
clothing. Keep pets and children away from the
generator when it is in operation.
PREPARATION BEFORE START
Selection and handling of fuel
–Only light diesel fuel can be used.
–The fuel must be filtered .
–Fuel should be free of water or dust because these
can contaminate the fuel injection system.
–Do not overfill the tank beyond the top of the red plug
inside the fuel tank filter, use fuel gauge on top of tank.
–Do not smoke and allow sparks in the area where the
engine is refueled or where gasoline is stored.
–Do not spill fuel when refueling, make sure the filter
cap is securely closed.
Selection and handling of oil
–Set the generator on a level surface.
–Fill the engine oil into the inlet.
–To check the oil level, simply dip the dipstick into the
pan. Do not screw in the dipstick when checking.
though it is equipped with a low oil pressure warning
system.
–If your generator doesn’t start by the 5th attempted or
starts and cuts out, your oil level is to low and needs to
topped up.
NOTICE
Oil should be changed after the first 20 hours (or 1
month) of use and then every 3 months or 100 hours
of use.
Be sure to drain the oil while the engine is warm but
not hot . It is difficult to drain the oil completely after
cooling.
WARNING
NEVER add or attempt to change oil into the
generator while the engine is running.
Check air filter
–Loosen the wing nut, detach the cover of air cleaner
and remove the element. Do not wash air cleaner
element with detergent . Use water or petrol (MUST
allow to dry before replacing).
–The air cleaner element must be changed when the
output of engine decreases or the color of exhaust is
abnormal.
–Never run the generator without the air cleaner
element. This may cause rapid engine wear.
–Reattach the cover of air cleaner and tighten the wing
nut.
NOTICE
Nothing effects the performance and durability of
the generator more than the oil you use. If inferior oil
is used or if your engine oil is not changed regularly,
the risk of piston seizure, piston ring sticking and
accelerated wear of the cylinder liner, bearings and
other moving components increase significantly.
–Make sure to check the oil level and to refill with oil to
the specified level before starting the generator, even
Ensure no load on generator
–Turn off the main circuit breaker and any other loads.
–Be sure to turn off the main circuit breaker before
starting the generator. If the switch is not on the “OFF“
position, sudden application of load could be very
dangerous, when the diesel engine is started.
–The generator should be earthed to prevent electric
shocks. (Recommended).
Handling of dual voltage type generator
–Operation of change over switch: The AC circuit
breaker on the control panel must be set to ‘OFF’
position before running the machine. After starting
the generator, allow the speed to reach rated RPM
and then turn the AC circuit breaker to the “ON”
position, so that the receptical sockets can be used
for operating equipment.
4
Page 5
WPE DIESEL GENERATORS
OPERATION
–NEVER try to switch between voltages when the AC
circuit breaker is ON and equipment plugged IN.
–Set the main AC circuit breaker to the “OFF” position
when using the 12v DC power supply.
Check for Airlock
WARNING
The FUEL and engine OIL are drained off by factory
prior to transportation. Generators are dry for
storage.
–Check for airlock in fuel pipeline, and find whether
there is air mixed into the pipeline, if yes, drain away
the air from the pipeline before refuel and start the
diesel engine.
–Fuel filter should be minimum 75% full, if not then air
may be present in system.
–The method to remove is, loosen the 17mm gland
nut connection between injecting pump and high
pressure brass pipeline, put run lever to “RUN”
position and turn over the engine until fuel starts to jet
out.
–Replace and re-tighten 17mm gland and repeat the
process if engine still does not start.
OPERATION
Break-in operation
While your generator is still new, application of heavy
loads may shorten the life of the engine. Follow the breakin procedures during the first 20 hours.
1. Avoid applying any heavy load during the break-in
period.
2. Change engine oil regularly. Change the engine oil
every 20 hours or one month after the initial use, and
every 3 months or 100 hours thereafter.
Starting the generator
Recoil start (Open Frame Type Only)
1. Open the fuel cock (at the “ON” position).
2. Put the engine speed lever in the “RUN” position.
3. Pull out the recoil starting handle.
4. Pull out the handle to the point where your hands
feel strong resistant and then return it to the initial
position.
5. Push down the decompression lever. (It will return
automatically when the recoil starter is pulled).
6. Pull out the recoil starting handle briskly with both
hands.
7. Do not allow the handle grip to snap back against
the engine. Return it gently to prevent damage to the
starter.
EN
Low oil warning system
–Device works to stop the engine automatically when
the oil pressure falls below the regulatory level and
will prevent engine seizure when the engine oil is
running low or engine pressure is lost.
–The oil temperature will rise high if the engine is
operated with insufficient engine oil. On the other
hand, too much oil is dangerous because the oil may
combust and cause a sudden and excessive rise in
engine rpm, so before operating the machine each
day be sure to check the oil and fill oil to the specified
level if necessary.
Opening the cabinet door and cover.
Opening the cabinet door and raise the door and check
daily.
1. Turn the handle anticlockwise to open cabinet door.
2. Turn the handle clockwise to lock cabinet door.
WARNING
NEVER pull out or touch the recoil when the diesel
engine is running, otherwise it will damage the
engine.
8. In cold weather, when diesel engine is difficult to
start, remove the plug from the rocker arm cover and
add 2 cc of engine oil.
9. Replace the plug before starting.
10. Always keep the red plug in the cover except
when adding oil, otherwise rain , dirt and other
contaminants may enter the engine and cause
accelerated wear of internal engine parts. This in
turn can cause serious problems.
Electric Start
1. Turn ignition key clockwise to ‘ON’ position.
2. Put the engine speed lever in the “RUN” position.
3. Turn the ignition key clockwise to “Start” position.
4. Release your hand from the key as soon as the
engine starts and let the key return automatically to
initial ‘ON’ position.
5
Page 6
WPE DIESEL GENERATORS
OPERATION
5. If the starter motor doesn’t engage and turn over the
engine after 10 seconds, please wait for about 30
seconds before attempting to start again and repeat
this process. .
WARNING
Please Note: If the starting motor is run for too long it
will flatten the battery.
Always leave the starting key turned 1 position, in the
“ON” position, while the engine is running.
Battery
Check the level of the fluid in the battery once every
month. When the level drops to the lower upper mark
replenish with distilled water up to the upper mark.
If battery fluid is low, the engine may fail to start because
too little electricity is reaching the starter motor. Always
keep the fluid level between the upper level and lower
level.
If too much battery fluid is applied, the fluid may spill and
corrode the surrounding parts. DO NOT over fill.
2. The speed of generator must reach rated speed
(lever at top).
3. Generator can load when the indicator of voltmeter
shows at 240±10% (50Hz) on the panel of control box.
4. Plug in the appliance.
WARNING
Do not start two or more machines simultaneously.
Start them one by one. Do not use floodlights
together with other machines.
5. Be sure that all pieces of equipment are in good
working condition before connecting them to the
generator.
6. If an appliance or piece of equipment begins to
operate abnormally, becomes sluggish, or stops
suddenly, turn off the generator immediately. Then
disconnect the appliance and examine it for signs of
malfunction.
7. If overloading of the circuit trips the AC circuit
protector, reduce the electrical load on the circuit,
and wait a few minutes before resuming operation .
Batteries are only covered by a 1 year warranty from
original date of purchase.
Operating your generator
1. Warm up the engine without load for about 3 minutes.
2. Our generator is equipped with low oil warning
system. The engine will stop automatically in case
of low oil pressure or a lubrication oil shortage. The
engine will stop immediately if restarted without a
lubrication oil refill. To check the oil level and refill
3. Do not loosen or readjust either the engine speed
limiting bolt or fuel injection limiting bolt (They have
been factory set) otherwise performance and fuel
economy will be affected.
Check during operation
1. (Any abnormal sound or vibration?
2. The engine misfiring or running rough.
3. What about the color of the exhaust gas? (Is it black
or too white?)
If you notice any of the above phenomenon, stop the
engine and consult your nearest dealer or contact
technical support on 44(0)1942 715 407.
8. If the LCD display voltmeter is too low or too high,
stop the machine and examine it for cause of fault..
DC Operation
The DC terminal may be used for charging 12V
automotive type batteries only.
1. When using automotive-type batteries with battery
cables, be sure to disconnect the minus pole battery
cable from the battery before charging.
2. Start the engine.
3. Connect the charging cable to the battery terminals
and the DC terminals of generator.
Connect the positive battery terminal to the positive
generator terminal. Do not reverse the charging
cables, or serious damage to the generator and/or
battery may occur.
Do not allow the free ends of the cable to touch each
other. If this occurs, it will be short circuit the battery
When a large capacity battery is charged, excessive
current flows(the value varies depending on the
discharging condition) , and the fuse for the direct
current will blow.
AC Operation
1. Start the engine and make sure the ‘GREEN’ pilot
lamp turns on. If it does not, the filament may be
burnt out.
4. Batteries produce explosive gases. Keep sparks,
flames and cigarettes well away. To prevent the
possibility of creating a spark near the battery,
always connect the charging cables to battery first
and only then to the generator. When disconnecting,
6
Page 7
WPE DIESEL GENERATORS
MAINTENANCE
you should disconnect the cables at the generator
first.
5. Charge the battery in a well ventilated place. Before
charging, remove the cap from each cell of the
battery. Discontinue charging if the electrolyte
temperature exceeds 45°C.
WARNING
Do not attempt to start an automobile engine while
the generator is still connected to the battery.
NEVER try to use both DC 12 volt and AC at the same
time.
Stopping the generator
1. Turn off the AC circuit breaker.
2. Leave the engine speed lever in the “RUN” position,
operate the engine without load for approx 3 minutes,
DO NOT stop the engine suddenly because this may
cause the temperature to rise abnormal and cause
the nozzle to damage and seize the engine.
3. Push down the stop lever or Turn the ignition key
anticlockwise to “OFF” position .
WARNING
If the engine keeps on running even after the speed
lever is pressed at the “Stop” position, turn the
ignition key to ‘OFF’ position. NEVER try to stop the
engine with the decompression lever (Open Frame
Type Only)
Remote Control (If Applicable)
Generator can be started or stopped remotely using a
wireless transmitter
1. Ensure lever is in ‘RUN’ position
WARNING
If Generator doesn’t start after 3 attempts,
steps 1-3 need to be REPEATED as well as general
maintenance of oil level and fuel level need to be
checked.
Never allow anybody other than the owner or
user to remotely start or stop the generator using
the wireless transmitter. Constantly starting and
stopping the generator will damage electric/
electronic components or equipment and also will
cause increased engine wear.
If the generator doesn’t not start at all after many
attempts there may be malfunction or fault and you
will need to contact your local service centre on
44(0)1942 715 407.
EN
MAINTENANCE
Periodic check and maintenance are very important for
keeping the engine in good condition. Please read the
detailed description of operating manual for each part.
Shut off the engine before performing any maintenance.
If the engine must run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
After the engine has been used, clean it immediately with
a cloth to prevent corrosion and remove sediment.
DA ILY
Check oil level Check and replenish fuel Check for oil leakage Check and tighten and engine parts if loose
FIRST 20 HOURS
2. Turn ignition key to ‘ON’ position (1 Clockwise Turn).
3. To start engine, press and hold button ‘A’ on
transmitter for approx. 3-5 seconds.
4. If generator does start check 1-2 and retry.
5. To stop engine press ‘B’ button on transmitter
6. Turn ignition key to ‘OFF’ position (1 Anti-clockwise
Turn)
WARNING
After the generator is stopped or not in use you
MUST turn the ignition key to the ‘OFF’ position
otherwise battery will flatten over time.
* Special tools or skills are required - please do not attempt
yourself - consult Technical Support on 44(0)1942 715 407.
Changing engine oil (Every 100Hrs)
Remove the oil filler cap. Remove the drain plug and drain
the used oil while the engine is still warm. The oil drain
plug is located on the bottom of the engine block next
to the oil filter. Tighten the drain plug and refill with the
recommended oil 10W30 Non or part synthetic.
Cleaning the oil filter (Every 300 hours)
(ONLY). Remove the lock nut, end cap and diffuser
discs and clean the carbon deposit.
Checking and replenishing battery fluid and charging
and battery (Monthly)
This diesel engine uses a 12v battery. The battery fluid will
be lost through continuous charging and discharging.
Before starting , check for physical damage to the
battery and also the electrolyte level, and replenish
with distilled water up to the upper mark if necessary.
When actual damage is discovered , replace the battery
immediately. Batteries are covered by 12 months
warranty from the original date of purchase.
STORAGE
If your generator should be stored in long time, the
following preparation should be made.
1. Operate the diesel engine about 10 minutes with NO
load and stop it.
2. Wait approx. 10 mins when the engine is still warm,
drain engine oil out, then refill new 10W30 engine oil.
3. Pull out the red plug on the cylinder head cover of
diesel engine and add 2ml of lubricate oil in cylinder,
and finally put the red plug back it to original place.
4. Maintenance of starting position
– Manual starting (Open Frame Type Only)
– Put the lever to the ‘RUN’ position
– Press the red pressure-reduce handle (noncompression position), pull the recoil handle 2-3
times. (Don’t start diesel engine).
Undo the 10mm bolt and Remove the oil filter (located
at the bottom of the engine block next to the oil drain
plug). Clean with water or petrol and DO NOT use any
detergents.
Changing the air cleaner element (every 300 hours)
Do not wash the air cleaner element with detergent
because this is a dry type element use water or petrol.
Allow to dry fully before replacing it.
WARNING
Never start the engine without the element, or with a
defective element. Change the element in time
Cleaning and replacing the fuel filter (Every 300
hours)
The fuel filter also has to be cleaned regularly to insure
maximum engine efficiency .
1. Drain the fuel (diesel) from the fuel tank.
2. Loosen the small clips on the hoses. Remove fuel
filter and Wash through thoroughly with diesel fuel
8
Page 9
WPE DIESEL GENERATORS
TROUBLESHOOTING
ProblemCauseSolution
No fuel.Add fuel.
The switch is not at “ON” positionTurn it to “ON” position
Engine will not start.
Engine will not start with Remote
Control.
Engine is running but no output.
The high pressure fuel pump,
injection nozzle cannot inject or
the fuel amount is insufficient.
The control lever of speed is not at
“RUN” position
Check oil levelAdd oil if needed
The speed and force to pull the
recoil starter is not enough
The injection nozzle is dirty or
blocked
The battery is flatRecharge or replace
Ignition key is not in the ON
position
Lever not i n to RUN position Check steps 1-3 on RC instructions
Oil or fuel level lowAdd oil or fuel if needed
AC circuit breaker is turned ‘OFF’Put the main AC switch to the “ON” position
The contact of socket is not goodAdjust the feet of socket
The rated speed of generator
cannot be reached
Other.
Remove the injection nozzle out and repair
it or bleed the fuel injection system.
Put the control level to “RUN” position
Start the diesel engine according to the
requirements of operating procedure of
start
Clean or replace injection nozzle
Check steps 1-3 on RC instructions
Adjust engine governor according to the
requirements
Contact Technical Support
44(0)1942 715 407.
TROUBLESHOOTING
EN
NOTE: When welding, if you find the electricity is too large for welder or the engine shuts down by overload during
welding, it may cause by the AVR’s regulator to damage or short circuit.
9
Page 10
WPE DIESEL GENERATORS
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
MODEL:6000S6500S6000S36500S3
Typ eSingle Phase A .CThree Ph ase A.C
Frequency (Hz)5050/605050/60
Rated Power (kW)4.55.0/5.55. 6kVA6.3/6.9kVA
Max Power (kW)5.05.5/6 .06 .2kVA6.9/7.5kVA
Voltage (A .C)110, 115, 220, 230, 240, 11/220, 115/230, 120/240240/415
Voltage (D.C)12V
Current (D.C)6A
Power Factor1.00.8
Phase NumberSingle PhaseThree Phase
Pole Number2
ExcitationSelf-excitati on
InsulationG1
Voltage Regulation SystemCondenser compensating system
Engine Type186FA Euro 5: L A186FAG188F Euro 5: LA186FAG186FA Euro 5 : L A186FAG188F Euro 5: LA188FG
Typ e4 Stroke, single cylinder, air cooled, direct injection diesel engine
Speed (rpm)3000/3600 Euro 5: 300030003000/3600 Euro 5: 3000
Bore x Stro ke (mm)86 x 728 8 x 7886 x 7288 x 78
Displacement (L)0.4180.4 740.4180.4 74
Cooling SystemForced Air Cooled
Lubrication SystemForced Lubrication
Lube oil capacity1.651.651.651.65
Start S ystemElectric Start
FuelDiesel
Fuel Cap acity (L)16161616
Low Pressure Alarm Included
Operation capacity (hr)7. 4/6.67. 2/6. 57.4/6 .67. 2/6. 5
Acid battery capacity (AH)24-36
Care free battery capacity (AH)17-36
Nett Wei ght (kg)150154150154
Dimen sions (L x W x H) mm900 x 520 x 70 0900 x 520 x 700900 x 520 x 70 0900 x 520 x 70 0
10
Page 11
WPE DIESEL GENERATORS
WARRANTY
WARRANTY
We at Warrior understand the importance of warranty for service & repair, we are now offering a standard 2 Year (Warrior Diesel Generators)
without the need for registering your purchase. We still have the option for product registration for customer who still would like to use the website
and to keep in touch with ourselves.
Please view the limitations below and read the full T&C’s about the warranty offered on a particular product.
All we require is the either a copy of the original proof of purchase or an invoice supplied from retailer at the time of purchase to enable the claim
to be raised. Please keep your proof of purchase safe for the duration of your terms, in the unfortunate event you need our technical support we
will ask for this to be provided on each claim, NO proof of purchase any warranty claim will be delayed or rejected.
Repair / Replacement Warranty
Warrior branded diesel generators warrants to the original purchaser up to 2 Years for domestic usage that the mechanical and electrical
components will be free of defects in material and workmanship for a period of Year One (1) [Parts and Labour] Year Two (2) [Parts Only] from the
original date of purchase or 1000 hours which ever comes first.
Industrial & Commercial Use One Year (1) [Parts and Labour] or 500 hours which ever comes first.
Transportation charges on any product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This
warranty only applies to the original purchaser and is not transferable.
Do Not Return the Unit to the Place of Purchase
Contact Warrior Technical Service and we will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, Warrior
will, at its option, authorise evaluation, repair or replacement of the defective part or component at our own Service Center. If and when an
product has to be replaced it will be on a like for like basis not old for new. Warrior will provide you with a case number for warranty service and
this can be monitored through your login account. Please keep it for future reference. Repairs or replacements without prior authorization, or at
an unauthorized repair facility, will not be covered by this warranty. We do have warranty exclusions for customers outside the United Kingdom
please see our full T&C’s.
Warranty Exclusions
This warranty DOES NOT cover the following:
Normal Wear
Your product needs periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a
part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts or labour if your product is deemed to have been misused, neglected, involved in an accident, abused,
overloaded beyond the generator’s limits, modified, installed improperly or connected incorrectly to any electrical component or system. Normal
maintenance is not covered by this warranty.
Other Exclusions
This warranty excludes:
– cosmetic defects such as paint, decals, etc.,
– worn parts including piston & rings, spark plugs, filters
– accessory parts including wheels & recoil assemblies
– failures due to acts of God and other force majeure events beyond the manufacturer’s control
– problems caused by parts that are not original Warrior Power Equipment parts
- alteration or modification(s) made by any party other than the manufacturer including exhaust extension and filtration systems.
- all hoses plastic or rubber, reducing valves and regulators
- any third party electrical equipment
EN
12v Battery
– All batteries supplied Over 1 Year Old.
Suitable Transfer Switch
Any MTS (Manual Transfer) & ATS (Automatic Transfer) systems other that ones supplied by ourselves under WARRIOR or Warrior will not be
considered suitable and will invalidate all warranties given. Please contact us direct before installing any Transfer system.
Limits of Implied Warranty and Consequential Damage
Winch Solutions Ltd (CG) disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim
costs by anyone using this product.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will
remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from
country to country. Your country may also have other rights you may be entitled to that are not listed within this warranty.
11
Page 12
WPE DIESEL GENERATORS
WARRANTY
Användarmanual
Dieselelverk
FÖR MODELLERNA:
6000S, 6000S3, 65000SV, 65000SV3
Teknisk support: 0046 31280985
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating
the product. Failure to do so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication but are subject to change
without notice.
REV 20210312
Warrio r Power Equipm ent, Unit 17-18, Br adley Hall Tradi ng Estate,Bra dley Lane, Sta ndish, Wi gan, WN6 0XQ, Un ited Kingdo m
12
Page 13
WPE DIESEL GENERATORS
INTRODUKTION
INTRODUKTION
Tack för att du köpte vår produkt.
Denna produkt garanteras mot felaktig tillverkning under
en period av 24 månader från inköpsdatumet. Förvara
ditt kvitto som bevis på köp.
Denna garanti är ogiltig om produkten visar sig ha
missbrukats eller manipulerats på något sätt eller inte
använts för det syfte som den var avsedd för. Felaktiga
varor ska inte returneras till inköpsplatsen, generatorn
ska returneras till leverantören av produkten. Ingen
produkt kan returneras utan föregående tillstånd. Denna
garanti påverkar inte dina lagstadgade rättigheter.
WPE TECHNICAL SUPPORT TEAM
0046 31280985
MODEL NUMBER
SERIAL NUMBER
VIKTIGT!
1. Barn bör hållas utom räckhåll från elverket
2. Ditt nya elverk kräver en inkörning under ca 10
timmar. Under dessa timmar skall elverket max
belastas med 75%. Efter dessa 10 timmar MÅSTE ett
oljebyte genomföras.
3. Rör inte motorn eller ljuddämparen medan elverket
är i drift. Var uppmärksam på varningsklistermärken
på generatorn.
4. Elektrisk utrustning (inklusive kabel- och
stickanslutningskomponent) bör vara i gott skick
innan start.
5. Om byte av säkringar sker måste det vara lika eller
bättre i specifikationen för den som ska tas bort.
6. På grund av hög mekanisk påfrestning
rekommenderas endast gummihöljerade kablar att
användas.
7. När du använder förlängningssladdar eller mobilt
distribueringsskåp ska ledningen med 1,5 mm2 area
inte vara längre än 60 meter; och 2,5 mm2 kabelarea
bör inte vara längre än 100 meter lång.
SV
DATE OF PURCHASE
PURCHASE LOCATION
8. Vid vanliga arbetsförhållanden kan generatorn drivas
vid normala driftsbelastningar. Om arbetsvillkoren
för omständigheterna inte är normala varken för
högt eller för lågt, bör generatorn köras med en lägre
utgång. När temperatur, höjd och luftfuktigheten är
högre än det normala arbetsförhållandet, MÅSTE
elverket minska utgångsbelastningen.
9. Innan någon kontroll eller underhåll av generatorn
måste motorn stoppas och låta svalna. Kontrollera
och underhåll generatorn enligt periodtabellen och
schemat i handboken.
10. Förutom det dagliga underhållet eller rengöringen,
bör inspektion eller omjustering utföras av
auktoriserad professionell person och originaldelar
användas.
11. Din nya maskin måste genomgå en inkörningstid på
minst 10 timmar, effekten ska inte överstiga 75% av
den maximala belastningen under denna tid.
13
Page 14
WPE DIESEL GENERATORS
FUNKTIONER
FUNKTIONER
WPE Dieselelverk innhar följande funktioner:
Serien med dieselelverk är av supertyst, lättvikt, luftkyld
och direktinsprutad 4-takts motor. De är utrustade med
två startsätt;
1. Dragstart med snöre
2. Elstart
Serien är utrustad med stora bränsletankar, säkringar,
AC- och ibland DC-utgångar, låg oljelarm samt autostopp.
Elverket kan fungera som en UPS där det automatiskt
startar om elnätet försvinner på många olika platser och
verksamheter.
Denna manual berättar hur du skall använda och sköta
ditt elverk. Var vänlig läs igenom den i sin helhet och
säkerställ att du är medveten om dess funktioner,
reglage och risker innan användning.
Vid frågor går det bra att ringa 031-280985.
PARAMETRAR
Elverken ger specifierad effekt när följande parameterar
uppfylls:
- Höjd över havet: <1000m
- Omgivningens temperatur: 5-40°C
VARNING
Avgasrör/ljuddämpare och avgaser är väldigt
heta. Installera aldrig någon ty pav förlängning på
avgassystemet – om detta sker upphör garantin att
gälla.
Undvik brännskador
Rör aldrig vid avgasrör, ljuddämpare eller motorn när
den körs eller strax efter. Vänta alltid 30 minuter efter
avstängning innan du vidrör något för att delarna skall
hinna svalna.
VIKTIGT!
Vänligen läs och förstå instruktionerna i denna manual
för att kunna använda ditt elverk på ett säkert sätt.
Användande på fel sätt kan innebära skador på person
och egendom.
Förebygga brand
Dieselmotorer kräver diesel som bränsle. Bensin och
andra drivmedel skall INTE användas i detta dieselelverk.
Torka bort allt spillt bränsle efter tankning. Förvara
inga lättantändliga vätskor eller material nära elverket
då värmen från avgasröret kan antända dessa. För att
undvika brand bör elverket ha minst 1,5m fritt utrymme på
alla sidor vid användning. Elverket skall användas på en
plan yta som inte är gjord av material som kan antändas.
Undvik att inandas avgaser
Avgaser innehåller den giftiga gasen kolmonoxid. Använd
aldrig elverket i slutna utrymmen. Sörj för bra ventilation.
Undvika brännskador
Ta aldrig på ljuddämparen eller andra delar nära
avgassystemet när elverket är igång eller nyss stoppat.
Elektriska stötar och kortslutning
För att undvika elektriska stötar och kortslutningar
- undvik att ta i elverket med fuktiga händer eller när
elverket självt är blött.
Elverket är inte vattentätt så det bör inte användas på
platser där det kan utsättas för regn, snö eller annan
väta.
VARNING!
De flesta förbrukare som du kopplar in kräver mer
än deras nominella Watt vid start. Överskrid inte
eluttagens effekt.
Ladda batteriet
Elektrolyten i batteriet innehåller syra. Skydda dina ögon,
hud och kläder. I händelse av kontakt med kroppen - skölj
noga med rent vatten och kontakta sjukvården vid behov.
Batteriet kan avge knallgas vilket är lättantändligt och
kan antändas vid laddning.
Ladda batteriet i väl ventilerade utrymmen.
14
Page 15
WPE DIESEL GENERATORS
FÖRBEREDESLSER INFÖR START
VARNING!
Lär dig hur du stoppar elverket snabbt och hur
reglagen fungerar. Låt aldrig någon använda elverket
utan träning och/eller utbildning.
Använd alltid skyddkläder så som t.ex. hjälm,
skyddsskor och bra klädesplagg i övrigt. Håll husdjur
och barn borta från elverket när det används.
FÖRBEREDESLSER INFÖR START
Drivmedel
–Endast vanlig diesel som säljs för bilar skall användas.
–Drivmedlet skall vara fritt från vatten och smuts då
detta kan skada bränslepump och insprutning.
–Dieseln måste filtreras
–Överfyll ej tanken. Fyll inte över den röda markeringen
inuti tanken.
–Du skall absolut inte röka eller vara i närheten av
gnistor, lågor eller andra källor till brand.
–En droppe diesel förstör en kubik rent vatten - spill
inte! Säkerställ att tanklocket är ordentligt åtskruvat
när du är klar..
innan start - även om elverket har en automatisk
avstängning vid låg olja.
–Om motorn inte startar på femte försöket eller startar
och sedan snabbt dör behöver oljan troligen fyllas på.
–Dränera oljan när motorn är varm. Det är svårt att
dränera den när motorn är kall.
NOTICE
Motoroljan bör bytas efter de första 20 timmarna
(eller 1 månad) och därefter var 100:e timme eller var
tredje månad.
VARNING!
Byt ALDRIG olja eller försök fylla på olja när motorn
är igång!
Kontroll av luftfilter
–Lossa vingmuttern, ta bort skyddet runt luftfiltret och
ta bort luftfiltret. Använd inte rengöringsmedel vid
rengöring.
–Luftfiltret måste bytas när det inte längre går att
rengöra det ordentligt eller när avgaserna får en
annorlunda färg.
SV
Val och hantering av olja
–Ställ elverket på ett jämnt underlag.
–Ta bort locket med oljestickan och fyll på olja. Överfyll
det ej.
–För att kontrollera oljenivån sticker du ner oljestickan
utan att skruva på det.
NOTICE
Val av olja har stor påverkan på maskinens
prestanda och livslängd. Var noga med val av
olja. Om fel olja används, eller inte byts enligt
underhållsschemat kan skador uppstå på motorn.
Skador orsakade av fel eller gammal olja täcks inte
av garantin.
–Använd aldrig elverket utan luftfilter. Detta kan orsaka
skada på motorn.
–Sätt tillbaka filter, kåpa och skruva fast vingmuttern.
Säkerställa att ingen last finns
–Stäng av huvudströmbrytaren och andra laster
–Var noga med att stänga av huvudströmbrytaren
innan elverket startas. Om brytaren inte är i läge OFF
kan inkopplade maskiner oavsiktligt startas.
–Elverket bör jordas för att minimera risken för
elektriska stötar. Använd jordspett.
Hantering av elverk med två Volt-typer
–AC-strömbrytaren på kontrollpanelen skall sättas
i läge OFF innan elverket startas. Låt sedan
elverket varva upp och gå en liten stund innan ACströmbrytaren slås på.
–Byt aldrig mellan två olika Volt när AC-strömbrytaren
är i ON och last inkopplad.
–När du vill använda 12V-DC uttaget skall AC-
strömbrytaren stå i läge OFF.
–Säkerställ oljenivån och var noga med att både byta
olja och fylla på vid behov. Kontrollera alltid oljenivån
15
Page 16
WPE DIESEL GENERATORS
DRIFT
Kontroll av luft i bränslesystemet
VARNING!
När elverket är nytt innehåller det inget bränsle eller
olja. Rester av detta kan dock finnas eftersom varje
Warrior-elverk testkörs innan det säljs för att du som
kund skall vara trygg i att det fungerar.
–Olja och diesel måste fyllas på innan uppstart när
elverket är nytt.
–Elverket bör ej heller transporteras med bränsle i
tanken.
–Om bränsletanken blivit tömd kan luft komma in i
systemet och förhindra diesel från att nå motorn.
Bränslefiltret bör vara minst 75% fyllt - annars är detta
ett tecken på luft i systemet.
–För att tömma bränslesystemet på luft lossar du
17mm bulten som finns mellan insprutningen och
mässingsröret. Sätt sedan reglaget i läge RUN och
starta elverket tills bränsle syns. Sedan kan bulten
skruvas på plats igen. Upprepa vid behov.
DRIFT
Start av elverket
Manuell start (gäller endast elverk av öppen typ)
1. Öppna ventilen i tanklocket till ON
2. Sätt gasreglaget i läge RUN
3. Dra i startsnöret tills du känner ett motstånd och för
det sedan tillbaka.
4. Tryck ner dekomprissionsspaken.
5. Dra i startsnöret med båda händerna hårt och
bestämt.
6. Låt inte handtaget slå emot motorn på tillbakavägen.
Återför det lugnt.
7. Vid kallt väder kan motorn vara svår att starta. Tillsätt
då 2cl motorolja.
VARNING!
Drag aldrig i startsnöret eller rör vid det när motorn
är startad.
8. Vid kallt väder blir en dieselmotor svår att starta.
Ta bort pluggen ur skyddet på vipparmen ovanpå
cylindern och häll i 2 cc motorolja.
9. Sätt tillbaka pluggen
Låg oljenivå och autostopp
–Elverket är utrustat med en automatisk avstängning
vid låg oljenivå. När oljetrycket minskas stängs
motorn av för att skada inte skall uppstå.
–Oljetemperaturen kan stiga om för lite olja används.
Om för mycket olja används kan en farlig förbränning
ske som rusar varvtalet på motorn. Säkerställ alltid att
rätt oljenivå efterlevs.
Öppna sido- och toppkåpa
Öppna upp sido- och toppkåpa ofta för att inspektera
elverket.
1. Vrid handtaget moturs för att öppna dörren.
2. Vrid handtaget medurs för att låsa dörren.
Inkörningsperiod
När ditt elverk är nytt skall tunga laster undvikas
då detta kan förkorta livslängden för elverket. Följ
inköriningsinstruktionen under de första 20 timmarna.
1. Undvik att belasta elverket mer än 75% under de
första 20 timmarna.
2. Byt olja regelbundet. Byt den efter de första 20
timmarna eller 1 månad efter första uppstart.
Därefter skall den bytas var 100:e timme eller var
tredje månad. 10W-30 olja rekommenderas.
10. Ha alltid den röda pluggen i sin rätta position förutom
just när du häller i olja. Annars kan främmande
föremål och smuts hamna i motorn.
Start med elektrisk start
1. Vrid tändningsnyckeln till läge ON
2. Sätt gasreglaget i läge RUN
3. Vrid tändningsnyckeln till läge Start
4. Släpp nyckeln när motorn tänder och låt den
automatiskt gå tillbaka.
5. Om motorn inte startar eller om startmotorn inte
aktiveras vänta 30 sekunder till nästa försök.
VARNING!
Vänligen notera: Om startmotorn körs för mycket
kommer batteriet laddas ur.
Lämna alltid nyckeln i läge ON när motorn körs.
Batteri
Kontrollera vätskenivån i batteriet en gång per månad.
När nivån understiger miniminivå ska destillerat vatten
fyllas på upp till markeringen.
Om batterisyranivån understiger gränsvärdet kan
det orsaka skada på batteriet med följd att elverket
inte kan startas. Om batteriet överfylls kan det skada
omkringliggande delar och material.
16
Page 17
WPE DIESEL GENERATORS
DRIFT
Batteriet omfattas endast av ett års garanti.
Användande
1. Värm upp motorn utan att koppla in last under tre
minuter.
2. Elverket är utrustat med låg oljenivå-vakt. Motorn
kommer stoppa automatiskt om oljenivån blir för låg.
Motorn kommer heller inte gå att starta om oljenivån
är för låg.
3. Undvik att skruva på bulten som begränsar
gas (varvtal) samt bulten som reglerar
bränsleinsprutning. Dessa två har justerats och
trimmats in på fabrik
Kontroll under drift
1. Något ovanligt ljud eller vibration?
2. Misständer motorn eller går ojämnt?
3. Färgen på avgaserna - är de svarta eller vita?
Om du upplever något av ovanstående bör du stänga av
ditt elverk och kontakta verkstad eller återförsäljare.
2. Starta motorn
3. Anslut laddningskablaget till batteripoolerna och till
elverket. Anslut pluspoolen till pluspoolen på elverket.
Förväxla inte polariteten - det kan skada både batteri
och elverk. Kablaget skall inte vidröra varandra.
DC-säkringen kan lösa om stora batterier laddas då
detta ger en högre strömstyrka.
4. Våta batterier avger knallgas när de laddas. Undvik
att vara nära gnistor, rökning och öppen låga. För
att minska risken för gnistor är det bäst att ansluta
kablaget till batteriet först och elverket sedan. När
kablarna skall tas bort är det omvänd ordning.
5. Ladda batterier på en välventilerad plats. När du
laddar våta batterier bör locken vara öppna. Avbryt
laddning om elektrolyten får en temp över 45°C.
VARNING!
Starta inte bilen när batteriet är ansluten till elverket.
Använd INTE DC- och AC-uttagen samtidigt.
SV
Stänga av elverket
Använda AC-ström (växelström)
1. Starta elverket och säkerställ att den gröna lampan
lyser
2. Elverket måste komma upp i normalt varvtal innan
last kopplas in.
3. När elverkets display visar 230V +/- 10% kan last
kopplas in.
4. Koppla in lasten.
VARNING!
Starta inte två inkopplade laster samtidigt. Börja med
den största av dem.
5. Säkerställ att all utrsutning är i gott skick innna de
kopplas in.
6. Om en inkopplad last beter sig onormalt så stäng
omedelbart av den, stäng av elverket och koppla ur
lasten.
7. Om överlast får säkringen att lösa så minska lasten
och vänta innan du återupptar drift.
8. Om displayen visar för hög eller för låg Volt - stoppa
och sök orsaken till felet.
Använda DC-ström (likström)
12V-uttaget ska endast användas för att ladda batterier.
1. Stäng av huvudströmbrytaren
2. Sätt gasreglaget i läge RUN och låt elverket vara
igång ett par minuter utan inkopplad last. Stäng
inte av elverket för snabbt då detta kan få motorns
temperatur att stiga för mycket.
3. Vrid nyckeln till OFF eller tryck ner Stoppknappen.
VARNING!
Om motorn fortsätter gå även efter att Stopphandtaget är i läge Stopp bör du stänga
bränslekranen. Stäng inte av motorn med
dekompressionshandtaget (endast öppna elverk)
Fjärrkontroll (om applicerbart)
Elverket kan startas och stängas av på distans via den
trådlösa fjärrkontrollen.
1. Sätt gasreglaget i läge RUN
2. Sätt startnyckeln i läge ON
3. För att starta motorn - tryck på knappen A på
fjärrkontrollen under 3-5 sek.
4. Om den inte startar, upprepa steg 1-2 och försök igen.
5. För att stänga av elverket trycker du på B på
sändaren
6. Vrid nyckeln till läge OFF
1. När du skall ladda bilbatterier med batterikablar ska
du först lossa minuskabeln från batteriet.
17
Page 18
WPE DIESEL GENERATORS
UNDERHÅLL
VARNING!
När elverket inte används eller är avstängt skall
nyckeln alltid stå i läge OFF.
VARNING!
Om elverket inte startar på tre gjorda försök måste
steg 1-3 upprepas. Det kan även behövas göras en
generell kontroll av bränsle och olja.
Låt aldrig någon annan starta eller stoppa elverket
med fjärrkontrollen när det är i drift. Upprepade start/
stopp för ofta kan skada elverket.
Om elverket inte startar använd felsökningen i denna
manual.
UNDERHÅLL
Periodiska kontroller och underhåll är en viktig del i
driften av ditt elverk. Det är väldigt viktigt att elverket
och dess motor underhålls kontinuerligt för att dess
prestanda och livslängd skall bibehållas.
Stäng av elverket innan något underhåll utförs. Om
motorn måste vara igång är det viktigt att detta sker på
en välventilerad plats eftersom avgaserna är giftiga.
Rengör elverket med en trasa när det använts för att
förhindra rost och korrision.
DAGLIGEN
Kontrollera oljenivån Kontrollera och fyll på olja Kontrollera oljeläckage Kontrollera så att delar sitter fas
FÖRSTA 20 TIMMARNA - INKÖRNING
Byt olja Dränera bränsletanken Justera ventiler på in- och utlopp* Lap inlopp och avgasventiler*
Byt bränslefilter Lap intake & exhaust valves* Byt kolvringar*
VAR TREDJE ÅR
Byt bränsleledningar*
* *Speciella verktyg och/eller kompetens kan krävas. Detta bör
endast utföras av en verkstad.
Oljebyte (Var 100:e timme)
Avlägsna locket på oljepåfyllningen. Skruva ur
dräneringsbulten och dränera oljan när motorn är varm
men avstängd.
Dräneringsbulten är placerad längst ner på motorblocket
bredvid oljefiltret. När oljan är tömd skruvar du
åt dräneringsbulten och fyller på med ny olja. Vi
rekommenderar att du använder 10W-30 mineralolja.
Rengöra oljefiltret (Var 300:e timme)
Skruva loss 10mm bulten och ta bort oljefiltret. Du hittar
det långt ner på motorblocket bredvid dräneringsbulten.
Rengör med vatten eller bensin - använd EJ
rengöringsmedel.
Byte av luftfilter (Var 300:e timme)
Tvätta inte luftfiltret med tvål eller rengöringsmedel.
Använd bensin eller rent vatten. Låt det torka helt innan
du sätter tillbaka det.
Starta aldrig motorn utan ett luftfilter, eller med ett
trasigt luftfilter. Byt det vid rätt intervall.
Rengöra och byta bränslefilter (Var 300:e timme)
Bränslefiltret måste också underhållas med jämna
mellanrum för att säkerställa elverkets effektivitet.
1. Dränera återstående diesel från tanken
18
Page 19
WPE DIESEL GENERATORS
2. Lossa de små clipsen på bränsleledningarna. Ta bort
bränslefiltret och spola igenom slangarna med ny
diesel.
3. Öppna bränslefiltret och gör rent det. Avlägsna all
smuts och orenheter.
Kontrollera och fylla på batterivätska samt ladda
batteriet (månatligen)
Detta dieselelverk har ett 12V startbatteri. Batterivätskan
i batteriet kommer minska i takt med tiden och
användningen.
Innan du startar - kontrollera batteriet för fysiska skador,
vätskenivån samt fyll på med destillerat vatten vid
behov. Vid påfyllning skall det inte överstiga den övre
markeringen. Vid skada på batteriet eller när om dess
kapacitet är dålig bör det bytas. Batteriet omfattas av 1
års garanti från ursprungsköpet.
FÖRVARING
FÖRVARING
Om du skall förvara ditt elverk under en längre tid utan
att använda det bör följande göras:
1. Kör elverket i ca 10min utan last och stoppa det
sedan.
2. Vänta en stund och byt sedan olja medan motorn är
varm. Se “Oljebyte”.
3. Lossa den röda pluggen som finns ovanpå cylindern
och häll i 2ml olja. Stäng det röda locket igen.
SV
19
Page 20
WPE DIESEL GENERATORS
FELSÖKNING
ProblemOrsakÅtgärd
Inget bränsleFyll på bränsle
Brytaren är inte i läge ONVrid den till ON
Motorn startar ej
Motorn vill inte starta med
fjärrkontrollen
Motorn går men ingen el finns
Bränslepumpen eller spridarna
kan inte ge tillräckligt med bränsle
alt bränslet är inte tillräckligt
Gasreglaget är inte i läge RUNFör det till läge RUN
Låg oljenivåFyll på olja
Vid manuell start; Farten och
kraften i draget av dragsnöret är
inte tillräcklig
Insprutningen är blockerad eller
smutsig
Batteriet är urladdatLadda eller byt batteriet
Tändningsnyckeln är inte i läge ON
Gasreglage är inte i läge RUN
Låg olje- eller bränslenivåFyll på olja och bränsle efter behov
AC-brytaren står i OFFÄndra brytaren till ON
Glapp i uttagetKontrollera uttaget
För lågt varvtal på motornKontakta återförsäljaren
AnnatKontakta återförsäljaren
Rengör insprutningen eller töm systemet
på bränsle
Starta motorn genom att följa
startinstruktionen i denna manual
Rengör eller byt ut insprutningen
Gör om steg 1-3 i Start med fjärrkontroll i
denna manual
Gör om steg 1-3 i Start med fjärrkontroll i
denna manual
FELSÖKNING
OBS: Vid svetsning kan elverket överlastas pga svetsens stora startströmmar. Om elverket överlastas för kraftigt vid
svetsning kan elverkets AVR skadas.
20
Page 21
WPE DIESEL GENERATORS
WARRANTY
WARRANTY
We at Warrior understand the importance of warranty for service & repair, we are now offering a standard 2 Year (Warrior Diesel Generators)
without the need for registering your purchase. We still have the option for product registration for customer who still would like to use the website
and to keep in touch with ourselves.
Please view the limitations below and read the full T&C’s about the warranty offered on a particular product.
All we require is the either a copy of the original proof of purchase or an invoice supplied from retailer at the time of purchase to enable the claim
to be raised. Please keep your proof of purchase safe for the duration of your terms, in the unfortunate event you need our technical support we
will ask for this to be provided on each claim, NO proof of purchase any warranty claim will be delayed or rejected.
Repair / Replacement Warranty
Warrior branded diesel generators warrants to the original purchaser up to 2 Years for domestic usage that the mechanical and electrical
components will be free of defects in material and workmanship for a period of Year One (1) [Parts and Labour] Year Two (2) [Parts Only] from the
original date of purchase or 1000 hours which ever comes first.
Industrial & Commercial Use One Year (1) [Parts and Labour] or 500 hours which ever comes first.
Transportation charges on any product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This
warranty only applies to the original purchaser and is not transferable.
Do Not Return the Unit to the Place of Purchase
Contact Warrior Technical Service and we will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, Warrior
will, at its option, authorise evaluation, repair or replacement of the defective part or component at our own Service Center. If and when an
product has to be replaced it will be on a like for like basis not old for new. Warrior will provide you with a case number for warranty service and
this can be monitored through your login account. Please keep it for future reference. Repairs or replacements without prior authorization, or at
an unauthorized repair facility, will not be covered by this warranty. We do have warranty exclusions for customers outside the United Kingdom
please see our full T&C’s.
Warranty Exclusions
This warranty DOES NOT cover the following:
Normal Wear
Your product needs periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a
part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts or labour if your product is deemed to have been misused, neglected, involved in an accident, abused,
overloaded beyond the generator’s limits, modified, installed improperly or connected incorrectly to any electrical component or system. Normal
maintenance is not covered by this warranty.
Other Exclusions
This warranty excludes:
– cosmetic defects such as paint, decals, etc.,
– worn parts including piston & rings, spark plugs, filters
– accessory parts including wheels & recoil assemblies
– failures due to acts of God and other force majeure events beyond the manufacturer’s control
– problems caused by parts that are not original Warrior Power Equipment parts
- alteration or modification(s) made by any party other than the manufacturer including exhaust extension and filtration systems.
- all hoses plastic or rubber, reducing valves and regulators
- any third party electrical equipment
EN
12v Battery
– All batteries supplied Over 1 Year Old.
Suitable Transfer Switch
Any MTS (Manual Transfer) & ATS (Automatic Transfer) systems other that ones supplied by ourselves under WARRIOR or Warrior will not be
considered suitable and will invalidate all warranties given. Please contact us direct before installing any Transfer system.
Limits of Implied Warranty and Consequential Damage
Winch Solutions Ltd (CG) disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim
costs by anyone using this product.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will
remain calculated by reference to the purchase date of the original unit. This warranty gives you certain legal rights which may change from
country to country. Your country may also have other rights you may be entitled to that are not listed within this warranty.
21
Page 22
WPE DIESEL GENERATORS
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
MODEL:6000S6500S6000S36500S3
Typ eSingle Phase A .CThree Ph ase A.C
Frequency (Hz)5050/605050/60
Rated Power (kW)4.55.0/5.55. 6kVA6.3/6.9kVA
Max Power (kW)5.05.5/6 .06 .2kVA6.9/7.5kVA
Voltage (A .C)110, 115, 220, 230, 240, 11/220, 115/230, 120/240240/415
Voltage (D.C)12V
Current (D.C)6A
Power Factor1.00.8
Phase NumberSingle PhaseThree Phase
Pole Number2
ExcitationSelf-excitati on
InsulationG1
Voltage Regulation SystemCondenser compensating system
Engine Type186FA Euro 5: L A186FAG188F Euro 5: LA186FAG186FA Euro 5 : L A186FAG188F Euro 5: LA188FG
Typ e4 Stroke, single cylinder, air cooled, direct injection diesel engine
Speed (rpm)3000/3600 Euro 5: 300030003000/3600 Euro 5: 3000
Bore x Stro ke (mm)86 x 728 8 x 7886 x 7288 x 78
Displacement (L)0.4180.4 740.4180.4 74
Cooling SystemForced Air Cooled
Lubrication SystemForced Lubrication
Lube oil capacity1.651.651.651.65
Start S ystemElectric Start
FuelDiesel
Fuel Cap acity (L)16161616
Low Pressure Alarm Included
Operation capacity (hr)7. 4/6.67. 2/6. 57.4/6 .67. 2/6. 5
Acid battery capacity (AH)24-36
Care free battery capacity (AH)17-36
Nett Wei ght (kg)150154150154
Dimen sions (L x W x H) mm900 x 520 x 70 0900 x 520 x 700900 x 520 x 70 0900 x 520 x 70 0
22
Page 23
WPE DIESEL GENERATORS
WIRING DIAGRAM
WIRING DIAGRAM
EN
23
Page 24
WPE DIESEL GENERATORS
ENGINE PARTS DIAGRAM
ENGINE PARTS DIAGRAM
108
5
138
108
107
106
105
/
.
-
77
5
.
78
7
9
-
> _/ .
80
/
.
/
.
.
1
9
.
./
/
-
4
8
.
-
72
73
75
' -
'
5
6
-
-
'
40
14
-
24
Page 25
WPE DIESEL GENERATORS
ENGINE PARTS LIST
ENGINE PARTS LIST
EN
25
Page 26
WPE DIESEL GENERATORS
PARTS DIAGRAM
PARTS DIAGRAM
26
Page 27
WPE DIESEL GENERATORS
PARTS LIST
PARTS LIST
EN
27
Page 28
Loading...