Warnock Hersey Installation And Operating Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
WARNOCK HERS EY
CERTIFIED F OR CANADA AND USA
MODEL NORTHFIRE
DVR36H/DVT36H
DIRECT VENTED BUILT-IN
GAS FIREPLACE HEATER
FOR USE WITH NATURAL GAS AND PROPANE
INSTALLATION AND OPERATING INSTRUCTIONS
FOR YOUR SAFETY
DO NOT store or use gasoline or any other flammable vapors or liquids in the vicinity
of this or any other appliance
IF YOU SMELL GAS:
fire-parts.com
- Do not try to light any appliance.
- Open windows.
- Do not touch electrical switches.
- Extinguish any open flame.
- Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier’s
instructions.
- If you cannot reach the gas supplier, call the fire department.
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND
WARNING: Improper installation, adjustment, alteration, service or maintenance voids
all the manufacturer’s warranties and may cause property damage, personal injury or
loss of life.
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
Installer, please leave this manual with the appliance owner for future reference.
OPERATING THE APPLIANCE
NOT FOR USE WITH SOLID FUEL
200-0052 24JAN01
CONTENTS
Page
Introduction 2
General Information 3
Appliance Description and Dimensions 4
Installation Instructions 5 - 13
Operation Instructions 14 - 15
Maintenance 16
Trouble Shooting Instructions 17 - 18
Servicing 19 - 20
Important Information Form 21
fire-parts.com
Warranty 22
Parts and Accessories 23
Allowed Termination Location 24
Manufactured by Archgard Industries Ltd, British Columbia, Canada.
Patents Pending
INTRODUCTION
Thank you for purchasing the NorthFire-DVR36H/DVT36H Direct Vent Built-in Gas Fireplace
Heater.
The NorthFire-DV36H is one of the most advanced gas fireplace heaters on the market. It is
designed using the latest technology and manufactured to the highest quality.
Some of the many features are:
∗
Small Size The NorthFire-DV36H is compact enough to fit into almost any size
room.
∗
Heater Classification The NorthFire-DV36H is classified as a heating appliance. Therefore,
it can be operated continuously for zone heating.
∗
High Efficiency The NorthFire-DV36H has high efficiency, which means that it is
less expensive to operate.
∗ Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the
owner’s moods and heating needs.
∗ Solid Construction The NorthFire-DV36H is constructed mainly of satin coated and
galvanized steel for long life and durability.
Please read the manual carefully prior to installation and operation of the appliance.
fire-parts.com
Proper installation, operation and maintenance of the appliance will provide you with
many years of enjoyment.
CAUTION
Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and
stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the
appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Any parts removed or opened for servicing of the appliance must be properly replaced
prior to operating the appliance.
The appliance must be inspected before use and at least annually by a qualified service
person. More frequent cleaning maybe required due to excessive lint from carpeting,
bedding material, etc. It is imperative that the control compartments, burners and
circulating air passageways for the appliance be kept clean.
2
GENERAL INFORMATION
APPLIANCE CERTIFICATION
This appliance is listed by Warnock Hersey for use in both the United States and Canada. It is
tested and certified to the following US and Canadian gas appliance standards.
- ANSI Z 21.44-1995 / CAN 1-2.19-M81 Direct Vent Wall Furnaces,
- ANSI Z21.50-1996 / CGA 2.22-M96, Vented Gas Fireplace and
- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes.
Please contact Warnock Hersey or Archgard Industries Ltd., if you have any questions
regarding the certification of this appliance.
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer.
The installation must conform with the local codes or, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
CAN/CGA-B149, in Canada.
Electrical connections and grounding must conform with local code, or current National
Electrical code, ANSI/NFPA No. 70-1987, in the US and in Canada, the current Canadian
Electrical Code, CSA C22.1.
fire-parts.com
SPECIFICATIONS
Natural Gas (NG) Propane (LP)
Manifold Pressure
Min. Supply Pressure for Purpose
of Input Adjustment
Orifice Size
Nominal Input Rating
Output (Fan On) @ Max. Rating
Output (Fan Off) @ Max. Rating
Altitude
Primary Air Opening
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 m) above sea level. The appliance must be
properly de-rated and installed according to local codes, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
CAN/CGA-B149, in Canada.
1.6 - 3.5 in. w.c. (0.4 - 0.9 kPa) 6.0 - 10.0 in. w.c. (1.5 - 2.5 kPa)
0 - 4,500 ft. (0 - 1372 m) 0 - 4,500 ft. (0 - 1372 m)
1/4 in. (6.4 mm) 1/2 in. (12.7 mm)
3
APPLIANCE DESCRIPTION & DIMENSIONS
FRONT VIEW
TOP LOUVERS
GLASS DOOR
CONVECTION FAN
SPEED CONTROL
GAS VALVE
fire-parts.com
APPLIANCE DIMENSIONS
3/4”
36 1/4”
23 1/2”
3 1/2”
37 3/4”
TOP VIEW
* Except for the vent connector locations, the rear vented DVR36H and top vented DVT36H, have
the same physical dimensions.
FRONT VIEW
5 1/4”
SIDE VIEW
4
INSTALLATION INSTRUCTIONS
PRECAUTIONS
This appliance must be installed by a qualified gas installer and the installation conform to the
•
installation codes.
Provide adequate clearance around air openings of the appliance. Never obstruct front openings.
•
Provide adequate clearances for proper operation and servicing of the appliance.
•
This appliance must be properly connected to a venting system.
•
LOCATING GAS FIREPLACE
This appliance must be installed in any location that is free of plumbing, electrical wiring and heating or
air conditioning ducts. Select a location that is accessible for venting. See APPENDIX A.
ALLOWABLE TERMINATION LOCATIONS.
15 ft Max.
A
fire-parts.com
B
F
15 ft Max.
E
A Cross Corner
B Flush with Wall
C Flat on Wall Corner
D Flat on Wall
Island
E
Room Divider
F
C
D
*NOTE: Rear vented gas fireplace DVR36H can only be located in positions
A, B, C and D.
VENT TERMINATION
1. See “ALLOWABLE TERMINATION LOCATIONS” diagram (page 24) to establish a suitable vent
termination location.
2. In heavy snowfall areas make sure vent termination is located where it can not be blocked by snow or
snow from snow removal equipment.
3. Locate vent termination away from plants, bushes or any other object on or near the vent termination
that will interfere or obstruct the air flow around it.
4. DO NOT recess vent termination into walls, sidings or planters.
5. Vent terminations located below 7ft from grade level or anywhere it can be a burn hazard to the public,
such as patios and balconies, must be protected with an Archgard approved termination cage.
6. Always ensure bottom of Vent Terminal is a minimum of 12” above grade.
5
INSTALLATION INSTRUCTIONS
FRAMING DIMENSIONS
16”
*31”
36 1/4”
Cont...
fire-parts.com
* If more rigidity is required. A stud may be added to the back of the top nailing flange
after the fireplace is installed.
TERMINATION
FRAMING
16”
36 1/4”
11”
39 1/2”
28”
36 1/4”
10”
56”
6
INSTALLATION INSTRUCTIONS
CLEARANCES TO COMBUSTIBLES
Cont...
BACK
SIDES
TOP 0” to stand-offs
BOTTOM
ADJACENT SIDE WALL 1” to side of faceplate
MANTLE see diagram
VENT
Combustible mantle allowed in shaded area. Mantle
extension maybe increased 1” (25mm) for each
additional 1” (25mm) increase in clearance height.
0” to stand-offs
0” to stand-offs
0”
1” to outside side and bottom surface,
2” to outside top surface.
Minimum Height From Top Surround: 6”
6” (152 mm)
fire-parts.com
Minimum Height From Bottom of Applinace: 35”
VENTING
The appliance will not function without being connected to a proper venting system.
This appliance may use 4” and 7” gas flex vents with NorthFire-DV36H listed vent components, or Simpson
Duravent 4 x 6 5/8 direct vent systems with Simpson Duravent Adaptor (SDA-1). 7” dia. rigid vent may
directly replace 7” dia. flex vent in all applications.
For best venting performance using gas flex vent, here are some general venting rules that we recommend:
1. Use only 4”and 7” diameter 2-ply certified gas flex vent in a co-axial configuration.
2. Maintain a minimum clearance of 1” to the sides and bottom and 2” to the top outside surface of the vent
pipe and combustible material.
3. Observe any local code restrictions, if any, regarding the installation of this type of gas appliance.
4. Observe the venting chart given in this manual.
5. Use a vent spacer between the inside and outside flex vents at every 3 ft intervals.
6. Never slope horizontal running vents downwards.
7. Maintain at least an upward slope of 1” for every 1 ft of horizontal run on the rear vented models.
8. Terminate the vent with a vent termination supplied by Archgard Industries Ltd.
9. Support horizontal running vents every 3 ft to prevent it from sagging.
10.Wall terminal must be installed a minimum of 12” above grade measured from bottom of
terminal.