Kit for use with the 4iE
Components
Power Base
Stand Boiler Receiver
Power Adapter with 1m
USB Cable
3
+
Page 4
Kit
Step 1 - Download the MyHeating App
+
Page 5
The MyHeating app is available for iOS and Android devices via the App Store or Google Play. If you have not done so already, download the MyHeating app to your tablet or smartphone.
Registration
After the app has been successfully downloaded you will need to set up your MyWarmup account. The 4iE Device can be registered via the app or by visiting my.warmup.com
Kit for use with the 4iE
Step 1 - Download the MyHeating App
5
+
Page 6
Kit
Step 2 - Install the Boiler Receiver
+
Page 7
Kit for use with the 4iE
Step 2 - Install the Boiler Receiver (Electrician Required)
Before making any permanent xtures Warmup recommends progressing through to ‘Step 4 -
Pairing the 4iE & Boiler Receiver upon identifying preferred locations for the Boiler Receiver
and Power Base. This will ensure the wireless connection is not subject to range or interference issues once installed.
IMPORTANT INFORMATION: Installation of the Boiler Receiver should only be carried out by a
qualied electrician. It requires a permanent 230V supply.
The Boiler Receiver should be connected to the central heating fused spur or circuit breaker in accordance with current wiring regulations such that there is a single point of isolation for all interconnected devices.
Ensure that multi stranded wires are fully inserted into the terminals and secured tightly. Any loose strands should be trimmed as they could cause a short-circuit.
This product uses mains voltage electricity and work should only
be carried out by a qualied electrician. Electrical installation
to be in accordance with latest edition of BS7671 Wiring
Regulations and appropriate Statutory Regulations.
!
7
+
Page 8
Kit for use with the 4iE
Step 2 - Install the Boiler Receiver (Electrician Required)
The Boiler Receiver should be installed in the boilers vicinity. Large metal objects such as the boiler, hot water cylinder or radiators, should be at least 300mm away from the Boiler Receiver and not directly between it and the 4iE.
Loosen both screws at the bottom of the Boiler Receiver and remove the backplate.
Fix the backplate to the wall using xing screws
provided.
Make sure to avoid cables or pipes
which may be buried in the wall
!
8
+
1 2
Page 9
Kit for use with the 4iE
Step 2 - Install the Boiler Receiver (Electrician Required)
Wiring Diagrams
9
+
1 2 3 4
3
Page 10
Kit for use with the 4iE
Step 2 - Install the Boiler Receiver (Electrician Required)
After the Boiler Receiver has been wired correctly reattach the front panel to the back plate and tighten both screws to secure.
Restore power to the boiler. The LED on the
Boiler Receiver will ash
RED which means it has to be paired to the Power Base.
4
10
+
4
Page 11
Kit
Step 3 - Assembly
+
Page 12
Kit for use with the 4iE
Step 3 - Mounting
1
2
Remove the 4iE from its packaging. Loosen both closing screws located at the bottom of the 4iE. Separate the front housing from the back plate.
Thread the power cable through the Stand and connect to the Power Base from your +Kit. Clip the Power Base onto the Stand. Connect the plug to a wall socket.
For optimal performance the thermostat should be located in an area with good ventilation. It should not be beside a drafty window/door, in direct sunlight or above another heat generating
device (e.g. radiator or TV).
12
For Stand Mount
+
Page 13
Kit for use with the 4iE
Step 3 - Mounting
Remove the 4iE from its packaging. Loosen both closing screws located at the bottom of the 4iE Separate the front housing from the back plate.
Drill a hole in the wall to feed the USB Cable to your wall socket. Attach the Power Base from your +Kit to the wall using the
xing screws provided.
Connect the plug to the wall socket.
For optimal performance the thermostat should be located in an area with good ventilation. It should not be beside a drafty window/door, in direct sunlight or above another heat generating
device (e.g. radiator or TV).
13
For Wall Mount
+
1
2
NOTE: For detailed instructions, see online at www.warmupsmart.com/installation
Page 14
Kit
Setup
+
Page 15
15
Kit for use with the 4iE
Step 4 - Pairing the 4iE & Boiler Receiver
+
The LED on the Boiler Receiver will stop
ashing RED to indicate
a successful connection.
Using a device, such as a paper clip, press the pairing button, as shown above, on the Power Base to begin pairing.
2
Power button
LED
Pairing Button
3
Attach the 4iE front face to the Power Base and tighten both closing screws.
Before pairing, please make sure the Power Base and Boiler Receiver are powered. The LED on the Boiler Receiver will ash in RED slowly.
NOTE: If the devices have been paired before, hold the Power button on the Boiler Receiver for 6 seconds and then continue set up.
1 2 3
Page 16
Kit for use with the 4iE
Step 4 - Pairing the 4iE & Boiler Receiver
16
+
To check that the system has been installed successfully, increase the air temperature by setting a temporary override.
Once the 4iE has powered up, connect to your WiFi Network.
The heating indicator will appear on the 4iE, the light on the Boiler Receiver will turn solid GREEN and your heat system should now activate.
overrideWi-Fi
target
Warmup
until
backback acceptaccept
21.0°C 15min
4 5 6
Page 17
Kit for use with the 4iE
Step 5 - LED Indications
17
+
LED Colour LED Status Meaning
N/A Not lit Paired
Green Lit constantly Relay on
Red Flashing slowly Not paired
Red Flashing quickly Relay o
Red Lit constantly Communication Lost
Relay on
LED
LED Status
Page 18
Kit for use with the 4iE
Step 6 - Control in event of communications error
18
+
The Warmup +Kit for use with the 4iE has been designed to still provide heating control should the communication between the Power Base and Boiler Receiver be interrupted.
With the Power Base and Boiler Receiver paired and the thermostat calling for heat, the relay will be activated and the Boiler Receiver will show a constant green LED indication. If the communication between the Power Base and Boiler Receiver is lost, the green LED will remain on the Boiler Receiver for a period of up to 30 minutes.
If communication has not been restored after 30 minutes has expired, the Boiler Receiver will indicate a communications fault by displaying a red LED ashing quickly.
To activate the relay whilst communication has been lost, press the power button on the Boiler Receiver once. The LED indicator will change from a constant to quick ashing red.
To de-activate the relay whilst communication has been lost, press the power button on the
Boiler Receiver once. The LED indicator with change from constant red to ashing quickly red.
Once communication has been restored, the LED indicator will change back to constant green providing the thermostat is calling for heat.
Page 19
Kit for use with the 4iE
Step 7 - Address setting
19
+
Address Set-up
When using multiple +Kit’s, each Power Base should be set to a unique address to prevent interference. Use the dip switches on the Power Base to select the unique address. 1
Represents ON (up) and 0 represents OFF (down).
Dip Switches
Address 31
Address 61
Address 53
Address 62
Page 20
Kit for use with the 4iE
Step 7 - Address setting
+
Address Set-up
20
Page 21
Kit
Troubleshooting
+
Page 22
Kit for use with the 4iE
Troubleshooting
Due to the large number of dierent boiler systems and wiring plans in use, Warmup cannot
guarantee compatibility with a particular system. Compatible with Combi and System boilers
with 230VAC, volt-free or low voltage input up to 3A. The boiler manufacturer or manual will be able to conrm if the boiler is compatible with this.
Is the +Kit compatible with this heating system?
How do I re-pair the system?
4iE display is blank
4iE displays “er1 amb”
If the wireless connection is lost the LED on the Boiler Receiver will ash RED. If it does not auto reconnect, press and hold the power button on the Boiler Receiver for 6 seconds. Remove the 4iE from the Power Base and using a device such as a paper clip press the pairing button as shown on page 15. The light on the Boiler Receiver will ash GREEN twice to indicate a successful connection.
Note: You can manually override the system, should the wireless connection fail by pressing the power button on the Boiler Receiver as shown on page 17.
1. Check that the display/standby brightness is not on the lowest setting, “0”. To access
display/audio settings rst press the standby button at the bottom of the 4iE. Then press
menu, settings and display/audio settings & display brightness.
2. Verify that power is going to the 4iE. Check that the Power Base is plugged in.
+
22
The system type on initial setup should be set to “Central Heating”. If you are using the
Thermostat with a central heating system you will not have a oor sensor installed. Switch the Thermostat to air mode
>settings >heating preference >control >air/oor
Page 23
Dimensions 86 x 86 x 26.5mm
Power Supply 230V AC, 50Hz
Fuse T1.6A, 250V
Maximum Relay Load 3A, 250V
Operational Temperature Range 0°C - 50°C
Operational Humidity Range <95% RH
IP Rating IP40
Technical Specications
Dimensions (Assembled with 4iE face) 120 x 121.4 x 63.3mm
Power Supply 5V DC, 300mA
IP Rating IP30
Operational Temperature Range 0°C - 50°C
Operational Humidity Range <95% RH
Power Base
Boiler Receiver
RF Range (Open Air) Max. 100m
Communication Band 868 MHz
Radio Frequency Standards EN301 489-1 V2.2.0 / EN301 489-3 V2.1.1 /
EN300 220-1 V3.1.1 / EN300 220-2 V3.1.1 /
EN 62479:2010 / EN60950-1:2006/A2:2013
Wireless
23
Page 24
Contact Us
UK
0345 345 2288
702 & 704 Tudor Estate Abbey Road Park Royal London NW10 7UW
Warranty
Warmup plc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
(ii) contact Warmup. Warmup will determine whether the product should be returned, or replaced.
This warranty does not cover removal or reinstallation costs, and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation or damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above. WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY.
This Warranty does not aect your statutory rights.
Contact Warmup or visit www.warmup.co.uk for details
Warmup - IM - +Kit - V3.2 2017-11-06
NOTE: This product is in compliance with the essential requirements and other relevant provisions of the RED Directive 2014/53/ EU. The Declaration of Conformity may be consulted by visiting: http://www.warmupsmart.com/declarations-of-conformity/kit­declaration-of-conformity/
Loading...