WARMTEC T510 Weekly Programming Thermostat with LCD Screen Installation Manual
WARMTEC T510 Weekly Programming Thermostat with LCD Screen Installation Manual
T510. Weekly Programming Thermostat with LCD Screen
Weekly circulation, it is possible to set 6 periods called events each day with
different temperatures, also you can select "manual mode" or "temporary
control mode" according to your individual requirements. The thermostat is
recommended for the control of electric heating devices or on/off valve actuator
used in water-based heating systems.
Selection Table:
Built-in & floor sensor, floor limit sensor, period
programming
A pair of contacts for potential- free output
Technical data:
Voltage : AC230V (AC110V/AC24V available)
Power consumption : 2W
Setting range : 5℃~90℃
Limitation range : 5℃~99℃ (factory setting: 35℃)
Switching differential :0.5℃~10℃ (factory setting: ±1℃)
Ambient temperature : -5℃~50℃
Protective housing : IP20
Housing material : self-extinguishing PC
Daily use of the thermostat
1
)
on/off " "
2
)
In the manual mode,press " " or" "to make temporary control。
3
)
Press" " or" " to increase or decrease pre-set temperature.
4
)
Press" " and" "and hold for 5 seconds at the same time to adjust
time. Press " " to choose object to adjust; Press" " or" " to
increase or decrease your set values; Press " " to confirm and exit.
5
)
Press the " " key to select manual mode or clock-controlled program
mode.
6
)
It displays the time or the pre-set temperature alternately, and it displays
the measured temperature directly.
7
)
When you press " " and" "at the same time and hold for 5 seconds,
the thermostat will be locked/unlocked. When it is locked, no operation
can be carried out until it is unlocked.
Display symbols:
Manual mode
Period control mode
Heating
Getting up, the first period
Out in the morning, the second period
Going home at noon, the third period
Out in the afternoon, the forth period
Going home in the evening, the fifth period
Sleeping at night, the sixth period
Period programming
Press " " and hold for 5s to enter the mode of Period programming.
Set programmed temperature
Advanced setting (qualified person preferred)
When the thermostat is turned off, You can press" " and turn on it at the same
time ,then you can enter the mode of advanced setting.
Adjust measured temperature
IN: built-in sensor
OUT: floor sensor
ALL: both sensors
Adjust limitation value,
Limitation range:5℃~60℃
Adjust switching differential
Turn on/off Anti-frozen
function
00: 5/2 day mode
01: 6/1 day mode
02: 7 day mode
Potential- free
output and main
power output in
the
same/different
way
Change the present
linkage way
Delay time of
Potential- free
output
Change linkage delay time
9
Limitation temperature
setpoint
Reset to factory
settings
Press" "and hold for 5s,all
parameters will be reset
Sensor failure:
Please select the right sensor mode when operation, it will display the
"Err" symbol on screen far sensor failure, thermostat must be checked till
the fault is eliminated
Explanation of symbols:
Period mode
Antifreeze
temperature
Lock key
heating
power
NTC
Decrease keyIncrease key
Menu
Week
Time
Six period
Manual mode

WARMTEC T510 Weekly Programming Thermostat with LCD Screen Installation Manual
WARMTEC T510 Weekly Programming Thermostat with LCD Screen Installation Manual
Mounting steps:
1. Release the front cover by inserting a screwdriver
into bottom crack
2 Taking the backing plate apart according to the following
diagram
3 Mounted the backing plate in the wall socket by screwdriver
4 After connect wires, the thermostat mounted on the backing
plate and remounted the cover and frame
Connection diagram
1 2 3 4 5 6 7
X
L N
N1 L1
Sensor
AC230V
16A