WarmlyYours TWS6GRD10BH, TWS6GRD12PH Installation Manual

INSTALLATION GUIDE
For TWS6 Series hardwired towel warmers
TOOLS REQUIRED ACCESSORIES FOR SQUARE/ROUND MOUNTING TUBES
INSTRUCTIONS
Before using this product, please read the following instructions carefully and keep this pamphlet for future reference.
ABOUT THE PRODUCT:
This heated towel warmer is designed for drying/warming towels or clothes, it has a surface stabilized temperature of 122-131ºF, and it is used in household bathrooms and kitchens, as well as in hotels and restaurants or other public areas. This appliance uses a voltage of 120 VAC, and is manufactured according to cULus standards.
SAFETY PRECAUTIONS:
1. The towel warmer must be used with a Ground Fault Circuit Intercepter (GFCI) circuit.
2. This product is supplied with a three-prong plug or three-wire cable. To avoid unnecessary risk or danger, this product must be properly grounded.
3. Any repairs must be done by a qualified technician who is deemed qualified by industry standards. When any external wire fittings are required, the unit must be disconnected from the circuit.
WARNING:
1. Only use for drying textiles which have been dampened by water.
2. If heating wire is damaged, the whole product should be replaced.
NOTE:
1. In the event of any difference in technical specifications, please refer to the actual product.
2. Please wipe the towel rail with a soft, dry cloth when cleaning it. Do not use scrubbers or abrasive cleaners.
1+2
3
4
Installation Fittings:
(1+2): Mounting tubes (4 pieces) & Set screws (4 pieces) (3) 4 brackets (4 pieces) (4) Short mounting screws (3 pieces), Long mounting screw (1 piece) (5) Drywall anchor (4 pieces) (6) Long screws (4 pieces)
This product must be installed in accordance with the instructions in the manual and the NEC and CEC guidelines relating to electrical fixtures in bathrooms. The Towel Warmer must be on a GFCI
protected circuit and be wired by a professional who is certified to do electrical wiring.
In order to reduce electrical shock, this towel warmer should be installed on a 15A GFCI protected branch circuit (14AWG) and to an outlet box that is 4 inches (10.16 cm) high by 2 Inches (5.08 cm) wide.
5
6
1+2
3
4
5
6
Installation Support •(800) 875-5285 • WarmlyYours
ACCESSORIES
INSTALLATION GUIDE
For TWS6 Series hardwired towel warmers
a
c
b
4 PCS
3 PCS
1 PCS
h
i
1 PCS
j
d
e
f
g
INSTALLATION: (WARNING: The electrical
connection should avoid all water.)
Please refer to all the following steps if the wall brackets are taken apart from the vertical bars.
3 PCS
1 PCS
3 PCS
4 PCS
k
L
4 PCS
1 PCS
1 PCS
4 PCS
STEP 1
a
STEP 2
STEP 3
STEP 1: As shown in the picture, insert the
short mounting screw (d) through the tube in the center of the mounting tube (a).
c
STEP 2: Use the short mounting screw (d) to
fix the mounting tube (a) to the threaded metal pad on the vertical bar on the back of the towel warmer.
STEP 3: Screw down the short mounting screw
(d) with a screwdriver. Note that the set screw of the tube (a) should point towards the floor when the towel warmer is wall mounted. Fix the remaining two mounting tubes (a) to the vertical bars with threaded metal pads by repeating Step 1-3.
Please refer to Steps 5-11 if the wall brackets are fixed on vertical bars already.
STEP 4
Installation Support •(800) 875-5285 • WarmlyYours
STEP 4: Guide the electrical cord through the
electrical connection mounting tube (b) and use the long mounting screw (e) to tighten the electrical connection mounting tube to the vertical bar.
Loading...