WarmlyYours TWS1HRN08BH Installation Manual

INSTALLATION GUIDE
For TWS1-HRN08 hardwired towel warmers
TOOLS REQUIRED ACCESSORIES FOR SQUARE/ROUND MOUNTING TUBES
INSTRUCTIONS
Before using this product, please read the following instructions carefully and keep this pamphlet for future reference.
ABOUT THE PRODUCT:
This heated towel warmer is designed for drying/warming towels or clothes, it has a surface stabilized temperature of 122-131ºF, and it is used in household bathrooms and kitchens, as well as in hotels and restaurants or other public areas. This appliance uses a voltage of 120 VAC, and is manufactured according to cULus standards.
SAFETY PRECAUTIONS:
1. The towel warmer must be used with a Ground Fault Circuit Intercepter (GFCI) circuit.
2. This product is supplied with a three-prong plug or three-wire cable. To avoid unnecessary risk or danger, this product must be properly grounded.
3. Any repairs must be done by a qualified technician who is deemed qualified by industry standards. When any external wire fittings are required, the unit must be disconnected from the circuit.
WARNING:
1. Only use for drying textiles which have been dampened by water.
2. If heating wire is damaged, the whole product should be replaced.
1+2
3
4
Installation Fittings:
(1+2): Mounting tubes (2 pieces) & Set screws (4 pieces) (3) 3 brackets (2 large, 1 small) (4) Short mounting screws (3 pieces) Long mounting screw (1 piece) (5) Drywall anchor (3 pieces) (6) Long screws (3 pieces) (7) Mounting Shelf (1 piece) (8) Power-source faceplate with mounting bracket (1 piece)
This product must be installed in accordance with the instructions in the manual and the NEC and CEC guidelines relating to electrical fixtures in bathrooms. The Towel Warmer must be on a GFCI
protected circuit and be wired by a professional who is certified to do electrical wiring.
5
6
7
8
NOTE:
1. In the event of any difference in technical specifications, please refer to the actual product.
2. Please wipe the towel rail with a soft, dry cloth when cleaning it. Do not use scrubbers or abrasive cleaners.
Installation Support •(800) 875-5285 • WarmlyYours
In order to reduce electrical shock, this towel warmer should be installed on a 15A GFCI protected branch circuit (14AWG) and to an outlet box that is 4 inches (10.16 cm) high by 2 Inches (5.08 cm) wide.
ACCESSORIES
INSTALLATION GUIDE
For TWS1-HRN08 hardwired towel warmers
a
c
d
b
1 PCS
1 PCS
4 PCS
3 PCS
h
i
j
2 PCS
k
e
f
g
INSTALLATION: (WARNING: The electrical
connection should avoid all water.)
1 PCS
3 PCS
3 PCS
4 PCS
1 PCS
STEP 1
c
STEP 2
STEP 3
c
STEP 1: Remove and set aside the set screws (c)
from the top of the main assembly.
STEP 2: Slide the mounting shelf's collared feet (k) over the
top of the main assembly so that the mounting shelf is perpendicular to the main assembly.
k
Note: the hole's in the mounting shelf should face the same direction as the wiring from the back of the main assembly.
STEP 3: Secure the mounting shelf (k) fto the main
assembly by using the set screws (c) from Step 1.
k
Please refer to all the following steps if the wall brackets are taken apart from the vertical bars.
Please refer to Steps 5-10 if the wall brackets are fixed on vertical bars already.
STEP 4
STEP 4: Insert the short mounting screw (d)
through the tube in the center of the mount­ing tube (a).
Installation Support •(800) 875-5285 • WarmlyYours