METROPOLITAN PARTS LIST
ITEM PART# DESCRIPTION QUANTITY
a. 0005-58120-0000 Tube standoff, mounting, square, stainless SM 4
b. 0005-51220-0000 Screw, set, M5/6, socket 4
c. 0005-58200-0000 Screw, cross, pan head, M5*12 4
d. 0005-57500-0001 Anchor, drywall 4
e. 0005-58120-0001 Bracket, wall mount 4
f. 0005-51200-0000 Screw, cross, countersunk, 2*40 4
g. 0005-51820-0000 Wallplate, stainless, with grommet and ground 1
h. 0005-51200-0001 Screw wallplate, stainless 6/32 2
i. 0005-58820-0000 Tube, stainless, round, electrical 1
j. 0005-51900-0000 Wrench, hex, 2.5 1
n/a AK05-58020-0000 Parts kit assembly, SM 1
a.
f.
c.
e.
g. j.
i.
METROPOLITAN INSTALLATION MANUAL
ITEM# TW-MT-10PS-HW-HD
Page 2
2x4 stud
TOOLS REQUIRED
INSTALLATION INSTRUCTIONS
- Read all instructions carefully before you begin installation.
- Installation should be completed by a qualified person.
- WarmlyYours recommends mounting the left vertical rail mounts to a stud.
- Please dispose of packaging in a resposible manner.
1-2.
a
i
c
A B
C
a.
4 PCS
4 PCS
b.
4 PCS
d.
4 PCS
f.
4 PCS
c.
4 PCS
e.
1 PCS
g.
1 PCS
i.
2 PCS
h.
1
2
f
e
d
28
11/16
729 mm
anchor point*
anchor point*
wiring
18
1/2
469 mm
19
5/8
498 mm
3
7/16
87.4 mm
6
5/16
160 mm
6
5/16
160 mm
g
Please peel plastic film off of electrical plate
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
METROPOLITAN INSTALLATION MANUAL
ITEM# TW-MT-10PS-HW-HD
A B
C D
E
Note: Use a tape measure to measure the distance (on center) between the four mounting brackets. Use a pencil to mark locations A, B, C, D and E on the wall according the measurements. We suggest mounting the Towel Warmer at least 24” (600mm) above the floor. We suggest mounting the left rail of the towel warmer to a
stud, if possible.
2x4 stud
24” (600mm)
b
Page 3
TIMER INFORMATION
WarmlyYours towel warmers include our programmable timer for efficient, economical use.
Operation
Towel warmer runs at 100% power and will reach temperatures between 100° F and 140° F depending on the following factors: running time, number of towels, type of towels and ambient room temperature. For optimal performance, WarmlyYours recommends using Automatic Mode.
Automatic Mode
The programmable timer allows up to 14 events or two ON-OFF cycles per day. Easy programming allows you to set intervals of operation for each day of the week. Flip the panel switch up to access programming controls. Refer to control diagram for switch location.
Manual Mode
Timer can be set to operate in manual mode to function as a simple ON-OFF switch.
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
METROPOLITAN INSTALLATION MANUAL
ITEM# TW-MT-10PS-HW-HD
BLACK OR BLUE (HOT)
WHITE OR BROWN (NEUTRAL)
GREEN/YELLOW (GROUND)
2” x 4” ELECTRICAL
BOX FOR TIMER
2” x 4” ELECTRICAL BOX
TOWEL WARMER
HOT LOAD (BLACK OR BLUE)
LINE (BLACK)
NEUTRAL (WHITE)
LOAD (BLUE)
GROUND (GREEN/YELLOW)
120V TIMER
NEUTRAL LOAD
(WHITE OR BROWN)
ELECTRICAL ROUGH-IN
3-WAY WIRE (YELLOW)
On
On
120V AC HOT
NEUTRAL
GROUND
Page 4
SAFETY INFORMATION
• Towel warmers are designed to warm towels only and should not be
used for any other purpose.
• Never stand, sit on or hang on the towel warmer.
• Never allow children to play on or with the towel warmer.
• Make sure that the circuit breaker is shut off at the main electrical panel
before wiring or servicing your towel warmer.
• The towel warmer must be properly grounded.
• All wiring must be done in accordance with the National Electrical Code
(NEC) and Canadian Electrical Code (CEC) and should be performed by
a licensed professional who is certified to do electrcal wiring.
• Never place your towel warmer inside a shower, sauna or steam room.
• Never attempt to warm more than two (2) towels on the
towel warmer at a time. Overloading the towel warmer will cause the unit to become extremely hot and may result in a burn if touched.
• Towel warmers are cULus listed for use in U.S. and Canada.
CLEANING INFORMATION
While the towel warmer is warm, clean with a soft, non-abrasive, damp cloth. Once the towel warmer has cooled, lightly polish with a soft, dry cloth. Do not use abrasive cleaning powders, metal polish or chlo­rine-based cleaners on any part of the towel warmer.
INSTALLATION
This appliance must be installed in accordance with the instructions in the
manual and the NEC and CEC guidelines relating to electrical fixtures in
bathrooms. The towel warmer MUST be on a GFCI protected circuit and
wired by a licensed professional who is certified to do electrical wiring.
OPERATION
After installation is complete, connect the electric power and turn on the power switch, located on the bottom left of the unit. The unit will begin to heat. If the unit will not be used for an extended time, simply turn the unit off using the power switch.
IMPORTANT: READ BEFORE INSTALLING
1. Read installation manual and ALL instructions BEFORE you
begin installation.
2. WarmlyYours recommends mounting the left vertical rail mounts to a stud.
3. This product is not intended for commercial use. Residential use only. Do not put the unit into water. This product is for indoor use only.
4. If the heating wire inside the unit fails or becomes damaged, turn the unit OFF and contact WarmlyYours. Do NOT attempt to repair or remove the power switch or heating wire.
5. If you encounter any difficulties while installing your towel warmer,
call WarmlyYours for 24/7 installation support at (800) 875-5285.
6. If a return is necessary, please use original packaging if possible.
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
METROPOLITAN INSTALLATION MANUAL
ITEM# TW-MT-10PS-HW-HD
Loading...