Circuit Check Installation for
TempZone™ Cut & Turn Roll (Single conductor)
TempZone™ Standard Mat (Single conductor)
TempZone™ Custom Fit Mat (Single conductor)
1. LAY OUT THE WARMLYYOURS WARMING SYSTEM ROLL(S)
Lay out the roll(s) in accordance with the design layout and instructions provided
by WarmlyYours.
1
2. TEST THE CIRCUIT CHECK
Before connecting any wires, install the batteries in the device and turn it “on” and “off” to test
the alarm.
After confirming that the alarm is in good working order, connect the wires as follows:
• Connect 1
• Connect 2
• Connect both ground sheaths to the Green terminal.
st inner conductor core wire to the Black terminal.
nd inner conductor core wire to the Red terminal.
Turn on the Circuit Check and touch the ground sheath to one of the inner conductor wires.
This should activate the alarm.
If the Circuit Check does not pass all these tests, please call WarmlyYours Customer Service at
(800) 875-5285.
3. ACTIVATE THE CIRCUIT CHECK AND PROCEED TO INSTALL FLOORING
4. IF THE CIRCUIT CHECK ALARM SOUNDS, STOP!
The alarm sounding indicates a short in the circuit or break in the system. Check the trouble
shooting guide in the WarmlyYours installation manual or call 24/7 Installation Support at
(800) 875-5285.
WarmlyYours will supply a splice kit to repair the short for the cost of S & H.
Alternatively, the wire may be repaired by an electrician.
Note1: This device is NOT an Ohm meter. WarmlyYours requires that the roll be tested before, during and after
installation with a Digital Ohm meter.
Please turn over to view detailed illustrations for wiring
Tempzone to the Circuit Check
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
10059-E
Rev 3/2013
Circuit Check Installation
for TempZone Single, Standard
and Custom Fit Mats
Page 2
Wiring Tempzone to Circuit Check
CORE
RED
SHEATH
BLACK
GREEN
(Sheath)
CORE
ON OFF
Beginning Wire
From Warming System
Ending Wire
From Warming System
Wire Construction
1
2
TempZone Single Conductor MatsTempZone Standard and Custom Fit Mats
COLD LEAD
BRAIDED GROUND SHEATH
RED 240V
OR
WHITE 120V
BLACK
RETURN
WIRE
COLD LEAD
OUTER INSULATION LAYER
BRAIDED GROUND SHEATH
Notes:
1. “Beginning” wire is the lead wire from the start of the warming system roll.
2. “End” wire is the lead wire from the end of the warming system roll.
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
TAPE INDICATORS
RED 240V OR
YELLOW 120V
INSULATION
INNER
LAYER
10059-E
Rev 3/2013