WarmlyYours Sierra User Manual

Page 1
SIERRA INSTALLATION MANUAL
TOOLS REQUIRED
INSTALLATION INSTRUCTIONS
- Review instructions carefully before installation
- Installation should be completed by a qualified person
- Please dispose of packaging in a resposible manner
a.
b.
3/8
6-
162 mm
3/8
22-
568 mm
c.
anchor point*
18-
479 mm
7/8
d.
e.
anchor point*
1/8
3-
1/4
6-
159 mm
79 mm
wiring
f.
4 PCS
4 PCS
4 PCS
4 PCS
4 PCS
4 PCS
A B
a.
c.
Please peel plastic film off of electrical plate
i.
C
g.
2x4 Stud
b.
2x4 Stud
1
d.
2
e.
f.
2-2.
g.
h.
i.
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
1 PCS
2 PCS
1 PCS
Page 2
After installation is complete, connect the electric power and turn on the Power Switch, located on the bottom left of the unit. The unit will begin to heat. If the unit will not be used for an extended time, simply turn the unit off using the power switch.
1. Do not hook the unit up to a circuit until completely reading these instructions.
2. We recommend mounting the left vertical rail mounts to a stud.
3. This product is intended only for domestic use. Do not put the unit into water. Do not use in a sauna, shower cubicle or steam room. This product is for indoor use only.
4. If the heating wire inside the unit fails or becomes damaged, turn the unit OFF and contact WarmlyYours. Do NOT attempt to repair or remove the power switch or heating wire.
5. If you encounter any difficulties while installing your Towel Warmer, installation support is available by phone, 24/7 at (800) 875-5285.
SIERRA INSTALLATION MANUAL
SAFETY INFORMATION
• Towel Warmers are designed to warm towels only and should not be used for any other purpose.
• Never stand, sit on or hang on the Towel Warmer unit.
• Never allow children to play on or with the Towel Warmer.
• Make sure that the electrical circuit breaker is shut off at the main panel before wiring or servicing your Towel Warmer.
• The Towel Warmer must be properly grounded.
• All wiring must be in accordance with the National Electrical Code (NEC) and Canadian Electrical Code (CEC) and should be performed by a licensed professional who is certified to do electrcal wiring.
• Never place your Towel Warmer inside a shower, sauna or steam room.
• Never attempt to warm more than two (2) towels on the Towel Warmer at a time. Overloading the Towel Warmer will cause the unit to become extremely hot and may result in a burn if touched.
• Towel Warmers are cULus listed for use in US and Candian markets.
5. If a return is necessary, please use original packaging if possible.
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
CLEANING INFORMATION
Clean the Towel Warmer with a soft, non-abrasive, damp cloth while warm. Once the Towel Warmer has cooled, lightly polish with a soft dry cloth. Do not use abrasive cleaning powders, metal polish or chlorine based cleaners on any part of the Towel Warmer.
INSTALLATION
This appliance must be installed in accordance with the instructions in the manual and the NEC and CEC guidelines relating to electrical fixtures in bathrooms. The Towel Warmer must be on a GFCI protected circuit and be wired by a professional who is certified to do electrical wiring.
Page 3
SIERRA INSTALLATION MANUAL
120 Volt TIMER
TOWEL WARMER
LINE (black)
NEUTRAL (white)
LOAD (blue)
BLACK or BLUE (Hot)
WHITE or BROWN (Neutral)
2” x 4” ELECTRICAL
BOX FOR TIMER
120 a.c. HOT
NEUTRAL
GROUND
GREEN/YELLOW (Ground)
TIMER INFORMATION:
Towel Warmers are designed to warm towels only and should WarmlyYours Towel Warmers include our programmable timer for luxurious and economical use of the Towel Warmer.
On
Towel Warmer runs at 100% power and will reach temperatures between 100° F and 140° F depending on the following: running time, number of towels, type of towels and ambient room tempera­ture. For optimal use we recommend Automatic Mode.
Automatic Mode
Programmable Timer allows up to 14 events or Two ON-OFF cycles per day. Easy programming allows you to set intervals of operation for each day of the week. To access programming controls flip the switch panel up. Reference Diagram G for switch location.
Manual Mode
Timer can be set to operate in manual mode to function as a simple ON-OFF switch.
HOT LOAD (black or blue)
NEUTRAL LOAD (white or brown)
Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
GROUND (green/yellow)
2” x 4” ELECTRICAL BOX
Loading...