Premium Snow Melt Control
MODEL SCP-120
• Automatic snow/ice melting control
• Operates electrically- and mechanically - held contactors for pilot duty applications
• Accommodates MI, constant wattage and self-limiting heaters
• 120 VAC operation voltage
12.75"
(324mm)
5.5"
2mm)
• Multiple sensor capability
• Heater hold-on and test capabilities
• CSA Certifi ed for use in Canada and U.S.
• Simple to install and operate
• Low system costs
• Minimum energy costs
C
L
*1.3125"
(33mm)
*Conduit Entry 3 x 1-1/16" (27mm)
7.5"
(191mm)
9.125"
(232mm)
2.3125" (59mm)
**High Limit Sensor Probe
(one sensor included per control)
11.500"
(292mm)
*2.125"
(54mm)
C
L
*2.125"
(54mm)
DESCRIPTION
The SCP-120 Snow Melt Control, when used with compatible sensors, automatically controls snow/ice melting heaters, ensuring minimum operating costs. Typical applications include driveways, sidewalks, loading docks and stairs.
The adjustable hold-on timer continues heater operation for up to 10 hours after snowfall stops to ensure complete melting. The optional Remote Control Override RCO, can be located where system operation can be conveniently observed. It duplicates many of the controls and indicators on the SPC­120 front panel. It is used to clear tracked and drifting snow that may not land on a sensor.
**The calibrated 40°F to 90°F (4°C to 32°C) high limit Thermistor probe sensor (included) prevents excessive temperatures when using constant wattage and MI heaters. for testing the sensor, acceptable range is +/- 100,000 Ohms depending on temperature. It also permits safe testing at outdoor temperatures too high for continuous heater operation.
6.562"
(167mm)
*Entry Point
The SPC-120 provides a relay closure interface for use with Energy Management Computers (EMC). This feature can also be used for general purpose remote control, annunciation and other advanced applications.
All sensor and communications wiring is NEC Class 2. This simplifi es installation while enhancing fi re and shock safety. The SPC-120 can interface with up to six sensors from the AIR-SS product family. Using more sensors provides superior performance by better matching the controller to site performance requirements.
The SPC-120 is an exceptionally capable deicing controller. For complete information describing its application, installation and features, please contact Customer Service or check on the web www.WarmlyYours.com. UL Listed for use in Canada and U.S. Markets.
24/7 Installation Support • Lifetime Technical Assistance • Free Design Service • www.WarmlyYours.com • (800) 875-5285
SPECIFICATIONS
General
Area of use . . . . . . . . . . . . . .Nonhazardous locations
Approvals . . . . . . . . . . . . . . . .Type 873 Temperature Regulating Equipment
Enclosure
Protection . . . . . . . . . . . . . . . .NEMA 3R
Cover attachment . . . . . . . . .Hinged polycarbonate cover, lockable
Entries . . . . . . . . . . . . . . . . . .3 × 1-1/16”
Material . . . . . . . . . . . . . . . . .Polycarbonate
Mounting . . . . . . . . . . . . . . . .Wall mounted
Control
Supply . . . . . . . . . . . . . . . . . .120 VAC, 50/60HZ, 35VA
Load . . . . . . . . . . . . . . . . . . . .Load switching provided by Relay Panel (sold separately)
Contact type . . . . . . . . . . . . . .Form C
Maximum Ratings . . . . . . . . .Voltage: 240 VAC Current: 24 amps
Heater hold-on timer . . . . . . .0 to 10 hours; actuated by snow stopping or toggle switch
System test . . . . . . . . . . . . . . Switch toggles the heater contact on and off. If temperature exceeds high limit, heater cycles to
prevent damage.
Snow/Ice Sensors
Sensor type . . . . . . . . . . . . . .Up to 6 sensors from the AIR-SS product family
Circuit type . . . . . . . . . . . . . . .NEC Class 2
Lead length . . . . . . . . . . . . . . Up to 500’ (152m) using 18 AWG 3-wire jacketed cable Up to 2,000’ (609m) using 12 AWG 3-wire
jacketed cable
High Limit Thermostat
Adjustment range . . . . . . . . . .40°F to 90°F (4°C to 32°C)
Dead band . . . . . . . . . . . . . . . 1°F (0.6°C)
Sensor type . . . . . . . . . . . . . .Thermistor network
Circuit type . . . . . . . . . . . . . . .NEC Class 2
Lead length . . . . . . . . . . . . . . Up to 500’ (152m) using 18 AWG 2-wire jacketed cable
Up to 1,000’ (304m) using 12 AWG 2-wire jacketed cable
Energy Management Computer (EMC) Interface
Inputs . . . . . . . . . . . . . . . . . . . OVERRIDE ON (10 ma dry switch contact)
OVERRIDE OFF (10 ma dry switch contact)
Outputs . . . . . . . . . . . . . . . . . . SUPPLY (10 ma dry switch contact)
SNOW (10 ma dry switch contact) HEAT (10 ma dry switch contact) HIGH TEMP (10 ma dry switch contact) ALARM (10 ma dry switch contact)
Environmental
Operating temperature . . . . . . –40°F to 160°F (–40°C to 71°C)
Storage temperature . . . . . . . .–50°F to 180°F (–45°C to 82°C)
ORDERING INFORMATION
ORDER NUMBER DESCRIPTION ACCESSORIES
SCP-120 PREMIUM SNOW MELT CONTROL RCO REMOTE CONTROL OVERRIDE (OPTIONAL)
AIR-SS AERIAL-MOUNTED SNOW SENSORS (SOLD SEPARATELY)