Read all instructions before installing or using this heater.
Page 2
GENERAL
ETHERMA LAVA® design infrared heaters are versatile direct
heating devices. They are characterized, in particular, by their
elegant design, ease of installation and operation, high reliability and maximum radiation power with minimal convection.
These instructions provide important information on safety, installation, use and maintenance of the device. Please read the
information provided in these instructions carefully and keep
for reference in case you have questions at a later occasion.
The manufacturer shall not be held liable if these instructions
are not complied with. Devices may not be used for purposes
other than the intended use.
The packaging of your high-quality LAVA® design infrared heater is made from recyclable materials.
THESE INSTRUCTIONS MUST
› be given to the operator following installation. The operator
must also be instructed in the infrared heater’s functionality.
› be kept safe and transferred to the new owner in case of a
change in ownership.
WARNING:
overheating. Overheating may occur and the heating
element may be damaged by covering the front of the
device, e.g. with a hand towel.
WARNING:
device is damaged.
OVERHEATING AND OVERLOAD PROTECTION
All heaters have overheating protection which is activated in the
event of overheating. The device only resumes operation automatically again after having cooled down to below 113ºF/45ºC
The infrared heater may not be used if the front of the
Covering the surface creates a danger of
This heating device is not intended for the use by persons (including children) with a limited physical, sensory or mental
capacity or with a lack of experience and knowledge. Such individuals must be supervised by a person responsible for their
safety or instructed on use of the device. Children should be
supervised in order to ensure that they do not play with the
device.
This device can be used by children of 8 years and older and by
persons with reduced physical, sensory or mental abilities and
with a lack of experience or knowledge if they are supervised or
have been instructed on safe use of the device and understand
the resulting risks. Children may not play with the device. Children may not clean the device or perform maintenance on it
without supervision.
Children under the age of 3 should be kept away unless under constant supervision. Children between the ages of 3 and
8 may only switch the device on and off if they are supervised
or have been instructed regarding safe use of the device and
understand the resulting risks, as long as the device is placed
or installed at its intended place of use. Children between the
ages of 3 and 8 must not plug in the device, control the device,
clean it and/or carry out maintenance.
The device may only be operated once installed. This heater
may not be used in the immediate vicinity of a bath, shower or
swimming pool. When installing the device in a bathroom, the
device must be mounted so that switches or other regulators
cannot be touched by persons in a bathtub or shower. The heater may not be used in small rooms occupied by persons who
cannot leave the room independently, except where constant
supervision is guaranteed.
Some product parts can become very hot and cause burns.
Particular caution is required when children or vulnerable persons are present.
ATTENTION: Hot surface of the device may cause
burn injuries. Switch off the device and let it cool
down before carrying out maintenance and service
works.
ATTENTION: Strain of any kind on the surface,
whether from persons or objects leaning against it
or from other forces, must be avoided!
2
Page 3
NOTES
IMPORTANT NOTES:
› LAVA® infrared heating devices comply with relevant safety
requirements.
› Installation and initial start-up, as well as repairs and servicing,
may be carried out by a licensed specialist or qualied individual only. All safety regulations must be observed. This person
must verify rst whether the electrical in-house system
complies with the
the manufacturer is limited to supply of the device.
› Comply with country-specic safety regulations.
› Comply with local safety precautions.
› The devices are suitable for the installation on walls.
relevant standards. The responsibility of
SCOPE OF DELIVERY | PACKAGING
The LAVA® infrared heater must be mounted exclusively using
the xing components included in the package.
Screws and anchors (not included in the scope of delivery) must
STANDARD SCOPE OF DELIVERY FOR WALL MOUNTING:
› LAVA® 2.0 INFRARED HEATING
- 2 x mounting brackets
- 4 x hexagon bolts M8 x 16
› Protective areas must be observed in accordance with DIN
VDE 0100, part 701, when installing the device in bathrooms.
› Minimum distances must be adhered to.
› In bathrooms, the device must be mounted so that switches
or other regulators cannot be touched by persons in a bath-
tub or shower.
› Due to the low surface temperature at the rear side (up to
104ºF/40ºC) the infrared heater may also be mounted on wooden
panelling.
› The device is not intended for the use in wardrobes and
beneath church benches.
correspond to the construction material of the wall (masonry,
concrete, plasterboard, etc.). The surface of the wall must be
even.
ATTENTION: The wall must be even. Otherwise
damage of the surface of the LAVA® infrared heating device may occur.
CLEARANCES
INSTALLATION AND MINIMUM DISTANCES:
LAVA® infrared heating devices have to be mounted so that
ammable objects cannot catch re. Be absolutely sure to
comply with minimum clearances, in particular to highly combustible objects such as curtains, upholstered furniture, etc.
Please also make sure that the infrared heater can radiate
freely into the room.
ATTENTION: Strain of any kind on the surface,
whether from persons or objects leaning against it
or from other forces, must be avoided!
1.4" (35 mm)
1.4"
(35 mm)
1.4" (35 mm)
Dimensional drawing: minimum mounting clear-
ances
1.4"
(35 mm)
3
Page 4
WALL MOUNTING
INSTALLING THE INFRARED HEATER:
Please inspect the power supply cord to the heater and the surface before installation.
These must not show any signs of damage.
Fasten hexagon bolts loosely on the rear side of the device.
1. Select a position for the mounting brackets according to the illustrations on page 5, depending on the product type.
2. Drill the holes according to the hole clearances specied on page 13 or the drill template enclosed in the shipping box.
3. Screw on the mounting brackets using suitable anchors and screws.
4. Place the LAVA® infrared heater on the mounting brackets and tighten the screws.
ATTENTION: Screws and anchors are not included in the scope of delivery and must
correspond to the construction material of the wall.
ATTENTION: Verify minimum distances! Use required mounting holes!
Stud
Mounting Bracket
Drywall anchors and
screws must be used in
the remaining 2 holes
Stud
4
Page 5
HOLE CLEARANCES FOR HORIZONTAL WALL INSTALLATION
B
Connection line
B
A
C
A
Connection line
C
Type InstallationWidth ADistance BDistance CMounting brackets
The heater is designed for permanent connection to a suitable room thermostat. Please refer to the instructions of
the room thermostat.
ATTENTION: If the power cord of the unit is damaged, it must be replaced immediately.
Fix mounted thermostats should be mounted next to the heated room’s entry door at 4’ or 1.3m height from oors.
An alternate location is on an interior wall, not subject to direct sunlight. The thermostat should not be installed
within 3 feet of the LAVA. When not using an nSpiration series thermostat, power the control with a GFCI
Protected Circuit.
The device is connected with the supplied connector to a junction box supplying the AC power supply.
If a longer cable is required, it can be replaced by longer one, 18 AWG or Larger.
HEATING
The heater is controlled by the externally mounted thermostat, or other control.
GROUNDING
The heater is for use with 120 volts. The green-yellow grounding of the cord must be connected to a permanent
ground inside the junction box.
CONSULT LOCAL
ELECTRICAL CODE
CONCERNING DESIRED
LAVA MOUNTING LOCATION
ELECTRICAL BREAKER PANEL
15 AMP
120V
BREAKER
PROGRAMMABLE
TOUCHSCREEN THERMOSTAT
(UDG4-4999)
Neutral
White
Hot
Black
LAVA RADIANT PANEL
2” x 4” ELECTRICAL BOX
Hot Black
Neutral
White
Ground
POWER
SWITCH
BLACK
WHITE
GREEN
BLACK
WHITE
GREEN
HOT LOAD
(black or blue)
NEUTRAL LOAD
(white or brown)
GROUND
(green or yellow)
2” x 4” ELECTRICAL BOX
6
Page 7
USER INSTRUCTION
HEATING
Do not power-on unit until it is installed.
Depending on the thermal insulation quality in your home, the required heat output of the radiator will range from
3 to 20 W/ft² (30 to 200 W/m²). The LAVA® glass radiator has a very high radiation fraction and a low proportion of
convective heat output. The surface temperature, for safety reasons, is limited to appoximately 203ºF / 95 °C, thus
the overall performance of the device is limited. For this reason, these devices are used as a sole heating solution
only in very well insulated houses.
ETHERMA LAVA® glass radiators warm predominantly solid objects and only a small proportion of the air
directly, so these devices are ideal for supplementary heat. In order to achieve the same feeling of comfort as with
convection heating, the indoor air temperature can be lowered by 2-3 °C/F. Each degree reduction can save about
6% in heating costs, depending on the respective heating behavior and thermal insulation in the room. The unit can
be turned on when a seldomly-used room is occupied, to provide a warm, cozy feeling.
Fix mounted thermostats should be mounted next to the heated room’s entry door at 4’ or 1.3m height from oors.
An alternate location is on an interior wall, not subject to direct sunlight. The thermostat should not be installed
within 3 feet of the LAVA.
Depending on the size of the unit, the LAVA® glass radiator will require some time to reach its operating
temperature. The glass sheet consists of 1/4” (6mm) toughened safety glass (ESG). This glass is much more
durable than conventional glass, and is designed for signicantly higher impact forces. However, you should avoid
excessive use. In case of damage, ESG shatters into many small pieces with blunt edges, to minimize the risk of
injury.
Please note when choosing an installation location, that a very small percentage of toughened glass products can
exhibit “spontaneous breakage”, i.e. when the glass shatters. This can occur even when external inuence isn’t
indicated. Choose the installation location of the device so that there is no danger to people or nearby objects.
ATTENTION: Avoid any kind of load on the glass itself, especially directly on the edges!
Do not lean it against anything, or lean anything against it!
Please refrain from placing any objects between the LAVA® glass radiator and the persons to be heated. Objects
between the radiator and people will block the heat from the people themselves.
MAINTENANCE AND CARE
The LAVA® glass radiator is designed to give its heat over the glass surface in the form of far infrared radiation.
There are no moving parts located on the device that require special maintenance. For care of your glass radiator,
we recommend commercial glass cleaner. Please do not use abrasive cleaners, as these can cause scratches to the
glass as well as the painted surface. Clean the unit before every heating season, at a minimium of once a year.
ATTENTION: Prior to cleaning, please ensure that the LAVA® glass radiators are turned off at the circuit
breaker panel and that the unit is at room temperature!
SPARE PARTS
Please contact WarmlyYours for any replacement parts required. Only use original spare parts.
25024.8“ x 19.7“ 630x500mm18 lbs / 8kg
50024.8“ x 35.4“ 630x900mm33 lbs / 15kg
75024.8“ x 51.2“ 630x1300mm51 lbs / 23kg
100024.8“ x 63“ 630x1600mm73 lbs / 33kg
50035.4“ x 47.2“ 900x1200mm
75035.4“ x 63“ 900x1600mm51 lbs / 23kg
33 lbs / 15kg
TROUBLESHOOTING
Device does not heat:
• Circuit beaker tripped?
• Is external supply switch turned on?
• Is the temperature of the external thermostat set lower than the actual room temperature?
Radiant heat oputput not to expectations:
• Is the distance between glass radiation heater and person too great?
• Is the glass radiation heater undersized for the space?
• Are there objects between the person and the glass-radiation heater?
EQUIPMENT MARKINGS
Data is included on the rating plate. The rating plate of the unit can be found on top or on the left (depending on
the vertical or horizontal orientation of the unit).
Fig 10: Nameplate Fig 11: Warning on front side
8
Page 9
CONGRATULATIONS!
You have made a wise choice by choosing the ETHERMA LAVA® glass heating radiator. Thank you for your
purchase. The latest technologies and developments offer maximum comfort and safety. Each unit is tested
several times during the manufacturing process and tested before shipment to exacting quality control standards.
If you follow these installation and operating instructions, your LAVA® glass radiator will provide many years of
trouble free enjoyment!
WARMLYYOURS USA
590 Telser Rd,
Lake Zurich, IL, 60047
Tel: (800) 875-5285
Fax: (800) 408-1100
WARMLYYOURS CANADA
300 Granton Drive, Unit 4A
Richmond Hill, L4B1H7
Tel: (800) 875-5285
Fax: (800) 408-1100
9
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.