WarmlyYours IPEMGLSWHT0600, IPEMGLSMIR0600 User Manual

Page 1
Ember Infrared Heating Panels
Installation Manual
Free Design Service • 24/7 Installation Support • (800) 875-5285 • www.WarmlyYours.com
Page 2
Sections: page
1. General Product Information .......................................................................................................... 1
1.1. General Information About Infrared Radiant Panels ......................................................................... 1
1.2. General Information About Ember Panels ....................................................................................... 1
1.3. Various Applications And Models ..................................................................................................... 2
2.1. General Safety Instructions .............................................................................................................. 3
2.2. Special Safety Instructions ............................................................................................................... 3
3. Instructions For Installation and Use ........................................................................................... 4
3.1. Instructions For Mounting ................................................................................................................ 4
3.2. Instructions For First Use ................................................................................................................. 5
3.3. Instructions For Regular Use ............................................................................................................ 6
3.4. Instructions For Cleaning And Maintenance .................................................................................... 6
3.5.Instructions For Repair ...................................................................................................................... 6
6. Declaration of Conformity .............................................................................................................. 9
6.1. Transportation and Delivery .............................................................................................................. 6
7. Occurrence of an Error ...................................................................................................................... 10
8. Warranty .............................................................................................................................................. 11
Table of Contents
Page 3
Thank you for purchasing an infrared heating panel produced by
INFRAPOWER MANUFACTURING LTD., sold by WARMLYYOURS RADIANT HEATING.
THIS VERSION OF THE INSTRUCTION MANUAL HAS BEEN TRANSLATED FROM THE ORIGINAL GERMAN VERSION APPROVED BY TÜV RHEINLAND GERMANY. WE DO NOT TAKE ANY RESPONSIBILITY FOR THE TRANSLATED VERSION. PLEASE ASK YOUR DEALER FOR THE ORIGINAL GERMAN VERSION.
EMBER heating panels operate on electricity. According to this denition, these devices can be dangerous. It is, therefore, necessary to read these instructions carefully before use. If you have questions, we are also happy to help. Keep this manual in the vicinity of the device.
1.1 General Information about Infrared Radiant Panels
EMBER radiant panels are direct heating systems that use the principle of infrared heat radiation. They have very low energy
consumption and achieve a pleasant and comfortable indoor climate. The heat conductor is carbon ber.
EMBER panels convert electrical energy into heat with nearly 100% efciency. A special coating on the surface is optimized so
as to achieve maximum heat dissipation in the wavelength range from 7 to 10 um.
EMBER radiant panels heat a room just as the sun warms the earth. EMBER brings this infrared heat into your home,
minimizing your heating costs. The panels also have a healthful effect on the human body. The heat has a positive effect on the
human heart, especially for the elderly, children and newborns. It also has a very effective impact on people who are restricted in their movement. The use of EMBER panels can improve your overall health.
When the panels are in use, only 80% of traditional heating is needed, because the panels can boost the feeling of warmth in a room. Compared with traditional heating, savings up to 30% can be achieved with EMBER infrared heating panels. In transitional periods, this can rise to 60%.
1.2. General Information about Ember Panels
EMBER radiant panels can be used in different rooms and environments (for each application, see Section 1.3.). Depending
on the environment and nature of the desired application, various models are recommended (to nd the best model for
you, please contact your dealer). For all models and applications, be sure to follow the safety instructions for installation (see Section 3.1.).
EMBER radiant panels heat up in about 5 to 10 minutes. Your room will not feel warmer immediately, because the cold objects
in the room (furniture, walls, ceilings, oors, etc.) need to warm up rst. Once these things are heated, the warmth will spread
throughout the room and you will be able to reduce the length of time in which the heating panel is in operation. Hence, you can save a great amount of energy.
Depending on which EMBER model you have selected, the surface will heat from 176 to 257ºF (80 to 125 °C). All EMBER heating panels are equipped with temperature sensors that regulate the surface of the unit so that they do not overheat.
EMBER heating panels can also be used for different environmental applications. For further details, see Section 1.3.
1
General Product Information
Section 1
Page 4
2
General Product Information
1.3. Various Applications and Models
1.3.1. Ceiling Panels
In order to heat a room optimally, EMBER panels should be attached to the ceiling. This optimizes the radiation. Plus, it
saves space.
EMBER panels are light enough to be integrated into existing ceiling systems. Please note the necessary details for instructions described in Section 3.1.
1.3.2. Wall Panels
EMBER wall panels can be optimally used as a supplementary or primary heating system. Due to their thin and light structure and the differences in surface design, the panels are compact and suitable for almost all walls (please see the instructions for installation in Section 3.1.). Depending on the mounting position, EMBER wall panels have a convection heat share of almost 0%.
Section 1
Page 5
2.1. General Safety Instructions
All EMBER heating panels are only suitable for use as a heating element. Any improper use can present a signicant danger
to people, animals and the environment.
EMBER heating panels are not intended to be used by people (including children) with reduced physical, sensory or mental abilities or lack of experience and/or knowledge, unless they are supervised by a person responsible for their safety or have received instructions on how to use the device.
All heating panels must be kept away from children. Children should be supervised to ensure they do not play with the device.
EMBER heating panels are not suitable for use in rain or wet conditions, under water, and for any non-intended use.
For all EMBER heating panels, please observe the following installation instructions (see Section 3).
Each EMBER heater has a built-in safety switch that turns off the heating element automatically if it is overheating. By unplugging the unit and waiting for about 10 to 15 minutes, the safety switch is activated automatically and the unit is operational again.
2.2. Special Safety Instructions
DO NOT COVER. Warning: To avoid overheating, the heater must not be covered. Never cover the EMBER heating panel. This
can cause heat buildup.
The heater is very hot when in use (depending on model, up to 125° C or 257ºF). Contact could lead to serious burns.
Each EMBER heater is equipped with a power cord and plug. By using an optional adapter, you can operate the heater with a room thermostat. Make sure that nobody can trip over the cable. Protect the unit from overloading the circuit breaker, and
operate the equipment only as specied on the nameplate.
Do not use the EMBER heating panel if the power cord or plug is damaged. This should be checked before each use. Do not
drag or tear the main cable. Do not scrub the cable, and do not clamp the cable. Neither the cable nor the plugs may be
repaired or replaced. In case of damage, contact the manufacturer or distributor.
Never dip EMBER heating panels into water or put them in water. Also, people should never touch the heating element
while they are in the bathtub or shower. Do not use this device near a bathtub shower or swimming pool.
The heating panel can only be operated in a permanently mounted position (for more information on mounting, see Section
3.1.).
In case of damage to the heating panel or the circuit cable, immediately disconnect it from the circuit. (For further information about the warranty process, see Section 8).
To prevent damage and accidents, never open the device (see the detailed information described in Section 3.5.). If the device is opened, warranty and liability claims are not approved.
3
Safety Notes Before First Use
Section 2
Page 6
4
Instructions for Installation
3.1 Instructions for Mounting
EMBER panels must be mounted with the supplied original mounting hardware (aluminum proles at the back of the
panels and screws included). For panels that are used without the original mounting hardware, the warranty, liability and consequential damages are void.
EMBER panels must only be used in the manufacturer-related frames.
For panels that are used without the original frame, the warranty, liability and damages are void.
3.1.2. General Instructions for Mounting
Depending on the desired application (see Section 1.3.), different types of installation are provided. All EMBER panels come
with original mounting hardware (aluminum proles at the backside of the panels and screws for wall/ceiling mounting are
enclosed).
Make sure that the power plug is not plugged in during assembly. During installation of the unit, also make sure that the
heating panel is not in the “ON” position.
Do not make any holes in the heating panel. If holes have been made for any reason, do not operate the device. Please contact the manufacturer or dealer from whom you purchased the product.
To ensure a quick and easy installation, use the enclosed mounting template and follow the instructions for installation as described in detail.
If the device is installed in children’s rooms or rooms accessible to children, make sure that the device is suspended at least 4 feet above the ground.
DISTANCE TO BACKSIDE: EMBER panels output convection heat (not infrared radiation) at the backside only. Make sure
that the distance from the wall to the back of the heating panels (metal/aluminum plate) is at least 1 inch in order to ensure ventilation. This distance is always provided when you use the standard mounting hardware. If you use a different mounting system than the original, warranty as well as liability for consequential damages is void.
DISTANCE TO FRONTSIDE: EMBER panels send out infrared radiation only on the front side. Make sure that there is a
minimum distance of 10 inches between the front of the panel and any objects.
Do not mount the heating panel near a shower, tub or swimming pool. Make sure that the heating panel cannot be touched by any person who is in the bath or shower. In case of installation in wet rooms, the installation must be done by a licensed electrician.
Never mount the heating element in front of or immediately below a socket.
Make sure that the plug is accessible after installation of the panels and, if needed, can be immediately pulled.
If the heating panel is integrated in a permanent electrical installation or connection, a correctly sized circuit breaker is needed. This connection has to be carried out by a qualied professional.
Section 3
Page 7
5
3.1.3. General Information on Positioning
With infrared radiation, improper positioning can result in certain areas of space in a room experiencing a “shadow” effect. Optimal positioning can avoid shadow effects. For detailed information about the optimal positioning, please consult your
dealer where you purchased the EMBER panel.
3.2. Instructions for First Use
Note that Section 3.1. mentioned instructions for assembly.
Now connect the heating panel to a perfectly placed and installed pair of sockets (note the instructions mentioned above for
safety).
Now the heating panel can be put into operation. The startup heating time is approximately 5 to 10 minutes. Your room will not feel warmer immediately, because the cold objects in the room (furniture, walls, ceilings, oors, etc.) need to warm up rst. Once these surfaces are heated, the warmth will spread throughout the room and you will be able to reduce the
duration of time in which the heating panel is in operation.
Instructions for Installation
Section 3
Good Positioning Bad Positioning
Good Positioning Bad Positioning
Page 8
6
Instructions for Installation
3.3. Instructions for Regular Use
Do not place any clothing or other similar items on the heating element (FIRE DANGER). A sign is mounted on the front of
the panel and must not be removed.
When heating up or cooling down, the expansion and contraction of the heating panels can cause minimal noise. This is normal.
The heater is very hot in use. Contact could lead to serious burns.
All EMBER heating panels are equipped with temperature sensors that regulate the surface of the unit and prevent it from overheating.
If you do not use the heating panel for an extended period of time, it is advisable to unplug the unit.
The surface of the heating panels should be kept clean. Please refer to the instructions in Section 3.4.
3.4. Instructions for Cleaning and Maintenance
EMBER panels do not require any maintenance. If you nd any irregularities, unplug the power cord immediately and
contact your dealer, from which you purchased the panel.
To achieve the best results when cleaning, follow these steps:
Before cleaning, unplug the unit.
The heater is very hot during use (depending on model, up to 125° C or 257ºF, BURNING DANGER). Before you clean the
heating element, let it cool down for about 10 to 15 minutes.
Do not immerse the heating panel in water or spray it off. Never use a wet cloth. Clean with a duster or slightly dampened
cloth. Make sure that the heating element is completely dry before powering on the unit.
Do not use abrasives or other harsh cleaning products or rough cloths.
For ceiling panels, occasionally remove any dust on the top with a vacuum cleaner.
3.5. Instructions for Repair
In case of irregularities with the devices, always contact your dealer. Do not repair them yourself.
If a malfunction occurs, immediately disconnect the power cord. Do not use, or stop use immediately, if the unit is damaged, especially if the line cord, housing or heating panel itself are affected.
In addition, we ask you to carefully read the details in Section 8 about the processing of warranty claims.
Never remove the label or the warning sticker. The data on the nameplate are important for the warranty.
Section 3
Page 9
7
4. Technical Details
The following information provides general information applicable to the EMBER radiant panel line. Please nd additional information about performance, size and surface temperature on the sticker located on the back of the panels.
Technical Details
Section 4
INFRARED PANEL
POWER
INPUT
MODEL
600W
110V 60Hz
Page 10
Environmental Protection
5. Environmental Protection
Please note the following guidelines for disposing of packaging materials:
Packaging material made of cardboard can be recycled.
Keep plastic foils or packaging out of the hands of children. Please recycle the protective lm properly.
The heater, or parts thereof, may not be disposed with normal household waste, but must be taken to a collection point for recycling of electronic and electric devices. The symbol on the product, on the packaging and on this manual indicates this.
By recycling, you make an important contribution to protecting our environment. Please ask for details at your local authority or the appropriate disposal location.
Section 5
8
Page 11
6. Declaration of Conformity
We hereby declare that the heating panel to which this declaration relates, is compliant with the following guidelines and
standards:
UL 499:2005 R3.11 EN60335-1 CAN/CSA C22.2 No. 60335-1-11 EN60335-2-30 CAN/CSA E60335-2-30:2001 EN50366
6.1. Transport and Delivery
Each individual heater element is, after nal testing, packaged securely in suitable boxes and shipped. In order to provide
redress for damage during transit, we ask that you unpack the heating panel in the presence of the delivering carrier in case you notice damage on the corresponding transport document or packing slip.
Declaration of Conformity
Section 6
9
Page 12
7. Occurrence of an Error
Dear Customer,
Thank you for choosing a product from WARMLYYOURS RADIANT HEATING. Should there be an issue with your device, we ask you to rst contact the dealer from which you purchased the device. Should the problem not be solved in this
way, please send your device back to the dealer and enclose the following warranty card.
WARMLYYOURS provides on all EMBER radiant panels a 5-year warranty, from the date of purchase. Proof of
purchase is a guarantee slip.
Excluded from the warranty are external optical defects, beyond the damage caused by improper installation or faulty handling, or removed or obliterated serial numbers or mechanical damage.
Repairs by unauthorized third parties voids the warranty claim.
The warranty covers the repair or replacement of the defective part. Labor is not included.
Please call WarmlyYours at 800-875-5285 for 24/7 troubleshooting assistance.
Occurrence of an Error
Section 7
10
Page 13
Warranty Card
Section 8
EMBER® Warranty Information
Please complete and return the Warranty Card (online or you may send/fax this form)
www.warmlyyours.com/en-US/radiant-panel-heating/warranty/register or call (800) 875-5285 to register via phone or Fax us at (800) 408-1100
WarmlyYours.com Inc. warrants the WarmlyYours EMBER® (“the Product”) to be free from defects in materials and workmanship for 5 years from the date of sale, provided that the Product is installed in accordance with the accompanying Installation Manual, and any special written design or installation guidelines provided by WarmlyYours.com Inc. for this product, the National Electric Code (NEC) and Canadian Electrical Code (CEC), and all applicable local building and electrical codes. WarmlyYours makes no claim as to the amount of room temperature rise, the amount of time it takes to reach a given room
temperature, or the nal room temperature due to the innumerable
variables in building construction and environmental conditions. Any suspected defect must be reported immediately upon discovery. The determination of such a defect must be made by WarmlyYours. com Inc., or its authorized representative only. This warranty is null and void if the product is improperly installed, improperly operated, or abused.
WarmlyYours. com Inc. assumes no responsibility under this warranty for any damage to the product caused by any trades person, or visitor on the job site, or damage caused as a result of post installation work. Under this Limited Warranty, WarmlyYours.com Inc. will provide the following remedy: If the Product is determined to be defective in materials and workmanship, and has not been damaged as a result of misuse or misapplication, WarmlyYours.com Inc. will refund the original purchase price or replace the Radiant Panel, at WarmlyYours.com Inc. expense. WarmlyYours.com Inc. will not be liable for the labor required to replace the Radiant Panel. The Limited Warranty is null and void if the project owner or his representative attempts to repair the Product
without receiving authorization. Upon notication of a real or possible
problem, WarmlyYours.com Inc., will issue an Authorization to Proceed under the terms of the Limited Warranty.
Unit must be inspected for shipping damage at time of delivery. Warranty claims will not be accepted on damaged units that are installed. WarmlyYours.com, Inc. is not liable for loss or damage of
the device due to improper installation, theft, re, earthquake or other
natural occurrences.
Warranty is void if the Ember unit is tted with unauthorized replacement
parts, or non-approved additional components. Ember is not designed to come in contact with any item. Any damage to an item that contacts the Ember, or damage to Ember as a result of contact with an item, shall not be covered under this warranty.
Warranty is voided if the serial number tag is removed, damaged, or altered in any way.
WARMLYYOURS.COM INC. DISCLAIMS ANY WARRANTY NOT PROVIDED HEREIN, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. WARMLYYOURS.COM INC. FURTHER DISCLAIMS ANY RESPONSIBILITY FOR SPECIAL, INDIRECT, SECONDARY, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR USE OF THIS PRODUCT, INCLUDING INCONVENIENCE OR LOSS OF USE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE FACE OF THIS DOCUMENT. NO AGENT OR REPRESENTATIVE OF WARMLYYOURS.COM INC. HAS ANY AUTHORITY TO EXTEND OR MODIFY THIS WARRANTY UNLESS SUCH EXTENSION OR MODIFICATION IS MADE IN WRITING BY A CORPORATE OFFICER.
Controls sold under the WarmlyYours.com Inc. name are warranted for 3 year from the date of sale.
INSTALLER INFORMATION
Company Name Phone
Address Email
City State Postal/Zip
Fax
Product Serial Number:
HOMEOWNER INFORMATION
Name Phone
Address Email
City State Postal/Zip
Fax
Product Serial Number:
11
Loading...