WarmlyYours ERT12015X45, ERT24015X90 Installation Manual

Installation Manual for your
Environ™ Flex Roll System
For laminate/floating wood &
engineered wood floor coverings
Please read through these instructions carefully before you begin installing & check that you are aware of all the components required.
Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
11
CONTENTS
Product specications and details .............................................................................................................................................1
Introduction ...............................................................................................................................................................................2
Important Information ................................................................................................................................................................2
Controlling Your System ............................................................................................................................................................3
Professional Electric Installation ................................................................................................................................................3
Items required for System Installation .......................................................................................................................................3
Testing .......................................................................................................................................................................................4
Pre Installation Instructions .......................................................................................................................................................4
Compatible Underlayment .........................................................................................................................................................5
Compatible Wood Laminates ....................................................................................................................................................5
Installing the Thermostat ...........................................................................................................................................................6
Installation of Environ™ Flex Rolls ............................................................................................................................................7
Environ™ Flex Rolls Rules ........................................................................................................................................................8
PRODUCT SPECIFICATIONS AND DETAILS
Environ™ Flex Roll System
Environ™ Flex is an ultra thin electric radiant oor heating roll, primarily used under laminate and engineered wood.
The advantage of Environ™ Flex is the ease of installation and the even heating of your ooring. The roll is produced with materials that avoid restricted heating known as, “hot spots.”
Construction
The Environ™ Flex system is manufactured with uoropolymer insulated heating cables with reinforced metal braiding over two heating cores. The uoropolymer insulated heating cables are designed to be in between two layers of reinforced and durable aluminum. The uniform spacing of the heating elements, strengthened by the foil, ensures even heat distribution. The heating element is connected to a power-supply cable, which is located in one corner of the roll. The power lead is a at thin two-core exible cord, consisting of two insulated conductors with a metal sheath and an outer sheath. Environ™ Flex is supplied within the nominal heat output range of 140 W/m² (12 W/ sq. ft.) @ 120 V & 240 V. The power lead is 15 feet long.
Metal Braiding Connected to Ground
Conductor Wire
Primary Flouropolymer Insulation
1
Introduction
Thank you for purchasing the Environ™ Flex Roll System. This manual contains IMPORTANT information regarding the safe use and installation of your Environ™ Flex Roll System. Please read through the entire manual carefully before you install or operate your oor heating system.
Important Information
• Environ™ Flex Rolls are designed for installation directly under laminate/ oating wood and engineered wood, installed on top of an underlayment.
• Environ™ Flex Rolls are NOT designed for installation under ceramic tile, natural stone or other similar hard oor coverings; and MAY NOT be installed under nailed hardwood ooring. WarmlyYours sells products to heat these ooring surfaces – Contact us at: info@warmlyyours.com, or (800) 875-5285 for more information on other oor heating system options available.
• Environ™ Flex Rolls should be separated from other heat sources such as luminaries and chimneys.
• The minimum distance between adjacent runs should be at a minimum of 1.5” (40 mm).
• Do not install the Environ™ Flex Rolls at an ambient temperature below 5ºF (-15ºC).
• Environ™ Flex Rolls should not extend beyond the room or area in which it originates, as per the custom installation SmartPlan™.
• The Environ™ Flex Rolls must be spaced from the walls a minimum distance of 3” (76 mm).
• Certain underlayment types and thicknesses with laminates/oating wood are NOT compatible with Environ™ Flex Rolls (see page 5). DO NOT PLACE EXCESSIVELY HEAVY FURNITURE on your heated oor.
• Environ™ Flex Rolls must not be installed under cabinets or furniture that will be permanently installed and attached to the oor. Built-in cabinets and other furniture with solid bases must not be placed over the rolls.
• Environ™ Flex Rolls is not for installation in walls.
• Environ™ Flex Rolls should NOT be installed on top of other in-oor radiant heating systems (for example hydronic or in-slab systems) UNLESS the other system is permanently disconnected in such a way that it cannot be inadvertently switched on while the Environ™ Flex Rolls are also in use.
• The Environ™ Flex Rolls may NOT be installed on oors where radiant ceiling heating rolls are in use in the room directly below where the Environ™ Flex Rolls are installed.
• Environ™ Flex Rolls must not be installed in thinset cement, or in direct contact with a cement or concrete suboor or slab. There must be an underlayment under Environ™ Flex Rolls.
• Indicate which branch circuits supply the power to the Environ™ Flex Rolls and retain the UL labels for each heating roll in a convenient location, i.e. taped to the circuit breaker box, for reference by the electrical inspector or home owner. Leave one UL label attached to the Environ™ Flex Rolls. Attach warning label in a convenient location to show the room location where Environ™ Flex is installed.
• Use only listed conduit, ttings, and/or other listed components.
• In Canada, the installation should be done according to the provisions of the Canadian Electrical Code, Part 1, Section 62.
• When used in wet locations, the installation should be in accordance with the National Electric Code, NFPA-70 and CAN/CSA-C22.1, Canadian Electrical Code, Part I (CEC) and that nal acceptance is to be made in the eld by the Authority Having Jurisdiction (AHJ).
• Environ™ Flex Rolls should be connected to a CLASS-A Ground Fault Circuit Interrupter (GFCI). Some local electrical codes may require that a qualied electrician connect the system.
We want your installation to be trouble-free. If you are confronted with a problem you cannot solve, please do not hesitate to contact us at: info@warmlyyours.com, or call us any time, any day at (800) 875-5285.
2
Controlling Your System
WarmlyYours recommends a Class-A GFCI, UL/CSA/ETL or similar NRTL listed thermostat to control the Environ™ Flex Rolls. A programmable thermostat will allow you to set your oor warm-up time and will provide you increased energy efciency, by programming your wake up, away, bedtime, and vacation settings.
Most wood laminate manufacturers specify that their oors should not be subjected to temperatures in excess of 85ºF (29ºC). The only reliable way to achieve this is to install a temperature sensor directly under the Environ™ Flex Rolls. Check with your laminate manufacturer to see their recommendations for installing electric radiant heat under their oors.
Any of the thermostats from the WarmlyYours nSpiration Series can be set to the temperature recommended by the laminate manufacturer.
Professional Electric Installation
Attention: Some local codes require that a licensed electrician complete the nal connection of the oor heating system.
The installation of electrical systems presents a risk of re and electrical shock, which may result in personal injury. Caution should always be taken to guard against these risks. A qualied electrician should connect Environ™ Flex Rolls to the thermostat and/or to the electrical supply circuit. All such connections MUST be in accordance with the National Electric Code, Canadian Electric Code, and all local codes.
WarmlyYours strongly suggests a dedicated circuit for each system. A non­dedicated circuit can cause nuisance tripping of the GFCI built into the thermostat.
Items Required For System Installation
• The customized installation SmartPlan™ (oor plan layout)
• Ground Fault Circuit Interrupter (GFCI)
• Digital Ohm Meter (multi-meter)
• 4” x 4” extra-deep box with a single gang plaster ring
• Junction box for systems requiring more than 3 rolls
• Wire and appropriate-sized, non-GFCI breaker for supplying voltage
• Electrical conduit
• Adhesive tape
• Aluminum tape strips