WarmFlow TW180V, TW210V, TW250V, TW300V, TR250V User Instructions

...
Cylinder Manual
Incorporating: User Instructions
Installation Instructions Guarantee Registration
Open Vented Cylinders
Products covered by this manual:
Twin Coil
TW180V TW210V TW250V TW300V
Triple Coil
TR250V TR300V
LEAVE THIS MANUAL WITH THE END USER Q12-032 rev 02 Sep ‘11
INSTALLATION AND REGISTRATION
This appliance must be installed as described herein and the Guarantee Registration section completed and returned to the manufacturer with proof of purchase (e.g. receipts / invoices).
The complete guarantee policy statement is included in Section 6, page 9.
FAILURE TO CORRECTLY INSTALL AND REGISTER THIS PRODUCT WILL
INVALIDATE ALL GUARANTEES
TECHNICAL, SPARES & GUARANTEE CLAIMS
For technical advice about the installation or use of this appliance, please contact the Warmflow Customer Care Centre by post, phone, fax or email at the addresses below. Please also refer to our website.
Should replacement components be required, a list of available spares is provided in Section
5.2, page 8.
In the unlikely event that replacement components might be required within the guarantee period, please notify the Customer Care Centre in writing, by post, fax or email, stating the nature of the fault and the part number of the replacement components required.
Warmflow Customer Care Centre
Warmflow Engineering Lissue Industrial Estate Moira Road Lisburn BT28 2RF Northern Ireland
Telephone
United Kingdom: 028 9262 1515 Republic of Ireland: 048 9262 1515
Facsimile
United Kingdom: 028 9262 0869 Republic of Ireland: 048 9262 0869
Email
technical@warmflow.co.uk
Website
www.warmflow.co.uk
Page 2 of 9
1 USER INSTRUCTIONS
1.1 General Information
Your hot water cylinder has been designed to give many years of trouble free service and is made from hygienic, high grade, duplex stainless steel.
The flow temperature of the hot water can be adjusted to your requirements, and should ideally be set to 60°C. Choosing a higher temperature increases the energy required to heat the cylinder and maintain its temperature, costing more in fuel.
1.2 Cylinder Thermostat
All cylinders are fitted with cylinder thermostats to control the heat input to the cylinder from a remote heat source, such as a boiler, heat pump or solar thermal installation.
The temperature of each cylinder thermostat is adjustable between nominally 40°C and 70°C. Turn the control knob clockwise to increase temperature, and anticlockwise to decrease.
Each cylinder thermostat has a built-in manually reset safety thermostat which will ‘lock out’ in the event of the cylinder overheating and which will need to be reset in order to restore operation. Remove the lock-out cover and depress the red button to reset.
1.3 Immersion Thermostat
Isolate ALL electrical supplies to the appliance before removing the immersion cover.
All cylinders are supplied with an immersion heater to allow the cylinder to be heated electrically. The immersion heater has an immersion thermostat, the temperature of which is adjustable between nominally 10°C and 70°C. Remove the immersion heater cover and turn the control dial anticlockwise to increase temperature, and clockwise to decrease.
The immersion thermostat also has a built-in manually reset safety thermostat which will ‘lock out’ in the event of the cylinder overheating and which will need to be reset in order to restore operation. Remove the immersion heater cover and depress the red button to reset.
2 INSTALLATION REQUIREMENTS
The cylinder must be installed vertically (not on its side) in a frost-free indoor location. The cylinder must be open vented i.e. supplied via an open vented expansion tank and have a
vertical vent pipe of at least 19mm internal diameter. The mains water supply must be from a public source (i.e. not from a private borehole) and the
hardness of the water must be less than 200 mg/litre. Where hardness in excess of 200 mg/litre is experienced, a suitable and effective hard water treatment must be installed.
All 22mm coils must be fully pumped – gravity circulation is NOT suitable for the 22mm coils. Gravity circulation may only be used on the 28mm coil(s).